Staged proximal deployment of the Zenith TX2 thoracic stent-graft: a novel technique to improve conformance to the aortic arch.

Kölbel, Tilo LU ; Resch, Timothy A ; Dias, Nuno LU orcid ; Björses, Katarina LU ; Sonesson, Björn LU and Malina, Martin LU (2009) In Journal of Endovascular Therapy 16(5). p.598-602
Abstract
PURPOSE: To present a modification of the Zenith TX2 thoracic stent-graft that allows staged proximal deployment to improve apposition to the aortic wall. TECHNIQUE: Three standard Zenith TX2 thoracic stent-grafts and 3 modified versions were deployed in a glass model of the aortic arch. Deployment sequences were analyzed. In a patient with a 6-cm thoracic aortic aneurysm after a type B dissection, the modified Zenith TX2 thoracic stent-graft was deployed successfully and without complications; the proximal part of the stent-graft protruded less into the arch, significantly improving wall apposition. CONCLUSION: Staged proximal deployment with a modified Zenith TX2 thoracic stent-graft can improve orientation and wall apposition of the... (More)
PURPOSE: To present a modification of the Zenith TX2 thoracic stent-graft that allows staged proximal deployment to improve apposition to the aortic wall. TECHNIQUE: Three standard Zenith TX2 thoracic stent-grafts and 3 modified versions were deployed in a glass model of the aortic arch. Deployment sequences were analyzed. In a patient with a 6-cm thoracic aortic aneurysm after a type B dissection, the modified Zenith TX2 thoracic stent-graft was deployed successfully and without complications; the proximal part of the stent-graft protruded less into the arch, significantly improving wall apposition. CONCLUSION: Staged proximal deployment with a modified Zenith TX2 thoracic stent-graft can improve orientation and wall apposition of the first Z stent. A better proximal apposition may prevent early and late stent-graft complications. (Less)
Please use this url to cite or link to this publication:
author
; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Journal of Endovascular Therapy
volume
16
issue
5
pages
598 - 602
publisher
International Society of Endovascular Specialists
external identifiers
  • wos:000271308800010
  • pmid:19842728
  • scopus:71949109190
ISSN
1545-1550
DOI
10.1583/09-2787.1
language
English
LU publication?
yes
additional info
The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Emergency medicine/Medicine/Surgery (013240200)
id
7a6cd082-ff15-47d0-85c6-592e98819b32 (old id 1500177)
alternative location
http://www.ncbi.nlm.nih.gov/pubmed/19842728?dopt=Abstract
date added to LUP
2016-04-04 08:55:13
date last changed
2022-01-29 07:39:41
@article{7a6cd082-ff15-47d0-85c6-592e98819b32,
  abstract     = {{PURPOSE: To present a modification of the Zenith TX2 thoracic stent-graft that allows staged proximal deployment to improve apposition to the aortic wall. TECHNIQUE: Three standard Zenith TX2 thoracic stent-grafts and 3 modified versions were deployed in a glass model of the aortic arch. Deployment sequences were analyzed. In a patient with a 6-cm thoracic aortic aneurysm after a type B dissection, the modified Zenith TX2 thoracic stent-graft was deployed successfully and without complications; the proximal part of the stent-graft protruded less into the arch, significantly improving wall apposition. CONCLUSION: Staged proximal deployment with a modified Zenith TX2 thoracic stent-graft can improve orientation and wall apposition of the first Z stent. A better proximal apposition may prevent early and late stent-graft complications.}},
  author       = {{Kölbel, Tilo and Resch, Timothy A and Dias, Nuno and Björses, Katarina and Sonesson, Björn and Malina, Martin}},
  issn         = {{1545-1550}},
  language     = {{eng}},
  number       = {{5}},
  pages        = {{598--602}},
  publisher    = {{International Society of Endovascular Specialists}},
  series       = {{Journal of Endovascular Therapy}},
  title        = {{Staged proximal deployment of the Zenith TX2 thoracic stent-graft: a novel technique to improve conformance to the aortic arch.}},
  url          = {{http://dx.doi.org/10.1583/09-2787.1}},
  doi          = {{10.1583/09-2787.1}},
  volume       = {{16}},
  year         = {{2009}},
}