Status of the Single Stage AMS machine at Lund University after 4 years of operation
(2010) 11th International Conference on Accelerator Mass Spectrometry 268(7-8). p.895-897- Abstract
- The Lund SSAMS machine has been in routine operation since 2004. We present results from the last year of operation of the facility. The reference sample IAEA C7 and the "old" oxalic acid, Oxl, were used as secondary standards. As primary standard for calculations the OxII was used. The background and long term stability of the facility are discussed. We also report on the quality of the C-13/C-12 ratio from the SSAMS system. (C) 2009 Elsevier B.V. All rights reserved.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1618300
- author
- Skog, Göran LU ; Rundgren, Mats LU and Sköld, Pia LU
- organization
- publishing date
- 2010
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- keywords
- AMS, Radiocarbon dating, Single Stage AMS
- host publication
- Nuclear Instruments & Methods In Physics Research Section B-Beam Interactions With Materials And Atoms
- volume
- 268
- issue
- 7-8
- pages
- 895 - 897
- publisher
- Elsevier
- conference name
- 11th International Conference on Accelerator Mass Spectrometry
- conference location
- Rome, Italy
- conference dates
- 2008-09-14 - 2008-09-19
- external identifiers
-
- wos:000277462300054
- scopus:77949897042
- ISSN
- 0168-583X
- DOI
- 10.1016/j.nimb.2009.10.058
- language
- English
- LU publication?
- yes
- id
- b4779b87-32c7-46c6-a0aa-50d67a04811c (old id 1618300)
- date added to LUP
- 2016-04-01 13:14:42
- date last changed
- 2022-03-13 22:51:14
@inproceedings{b4779b87-32c7-46c6-a0aa-50d67a04811c, abstract = {{The Lund SSAMS machine has been in routine operation since 2004. We present results from the last year of operation of the facility. The reference sample IAEA C7 and the "old" oxalic acid, Oxl, were used as secondary standards. As primary standard for calculations the OxII was used. The background and long term stability of the facility are discussed. We also report on the quality of the C-13/C-12 ratio from the SSAMS system. (C) 2009 Elsevier B.V. All rights reserved.}}, author = {{Skog, Göran and Rundgren, Mats and Sköld, Pia}}, booktitle = {{Nuclear Instruments & Methods In Physics Research Section B-Beam Interactions With Materials And Atoms}}, issn = {{0168-583X}}, keywords = {{AMS; Radiocarbon dating; Single Stage AMS}}, language = {{eng}}, number = {{7-8}}, pages = {{895--897}}, publisher = {{Elsevier}}, title = {{Status of the Single Stage AMS machine at Lund University after 4 years of operation}}, url = {{http://dx.doi.org/10.1016/j.nimb.2009.10.058}}, doi = {{10.1016/j.nimb.2009.10.058}}, volume = {{268}}, year = {{2010}}, }