Are digital images good enough? A comparative study of conventional film-screen vs digital radiographs on printed images of total hip replacement.

Eklund, K. ; Jonsson, Kjell LU ; Lindblom, G. ; Lundin, Björn LU ; Sanfridsson, J. ; Sloth, M. and Sivberg, Bengt LU (2004) In European Radiology 14(5). p.865-869
Abstract
The aim of this study was to evaluate the inter- and intra-observer variability and to find differences in diagnostic safety between digital and analog technique in diagnostic zones around hip prostheses. In 80 patients who had had a total hip replacement (THR) for more than 2 years, a conventional image and a digital image were taken. Gruen's model of seven distinct regions of interest was used for evaluations. Five experienced radiologists observed the seven regions and noted in a protocol the following distances: stem-cement; cement-bone; and stem-bone. All images were printed on hard copies and were read twice. Weighted kappa, kappa(w), analyses were used. The two most frequently loosening regions, stem-cement region 1 and cement-bone... (More)
The aim of this study was to evaluate the inter- and intra-observer variability and to find differences in diagnostic safety between digital and analog technique in diagnostic zones around hip prostheses. In 80 patients who had had a total hip replacement (THR) for more than 2 years, a conventional image and a digital image were taken. Gruen's model of seven distinct regions of interest was used for evaluations. Five experienced radiologists observed the seven regions and noted in a protocol the following distances: stem-cement; cement-bone; and stem-bone. All images were printed on hard copies and were read twice. Weighted kappa, kappa(w), analyses were used. The two most frequently loosening regions, stem-cement region 1 and cement-bone region 7, were closely analyzed. In region 1 the five observers had an agreement of 86.75-97.92% between analog and digital images in stem-cement, which is a varied kappa(w) 0.29-0.71. For cement-bone region 7 an agreement of 87.21-90.45% was found, which is a varied kappa(w) of 0.48-0.58. All the kappa values differ significantly from nil. The result shows that digital technique is as good as analog radiographs for diagnosing possible loosening of hip prostheses. (Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
comparative study, total hip replacement, digital radiographs, analog radiographs
in
European Radiology
volume
14
issue
5
pages
865 - 869
publisher
Springer
external identifiers
  • pmid:14618365
  • wos:000220880400016
  • scopus:2542452919
  • pmid:14618365
ISSN
0938-7994
DOI
10.1007/s00330-003-2126-y
language
English
LU publication?
yes
additional info
The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Diagnostic Radiology, (Lund) (013038000), Division of Nursing (Closed 2012) (013065000)
id
16906a56-500b-480c-85e9-221a6a851411 (old id 118912)
alternative location
http://www.ncbi.nlm.nih.gov/sites/entrez?cmd=Retrieve&db=PubMed&list_uids=14618365&dopt=Abstract
date added to LUP
2016-04-01 11:43:24
date last changed
2022-04-28 19:06:11
@article{16906a56-500b-480c-85e9-221a6a851411,
  abstract     = {{The aim of this study was to evaluate the inter- and intra-observer variability and to find differences in diagnostic safety between digital and analog technique in diagnostic zones around hip prostheses. In 80 patients who had had a total hip replacement (THR) for more than 2 years, a conventional image and a digital image were taken. Gruen's model of seven distinct regions of interest was used for evaluations. Five experienced radiologists observed the seven regions and noted in a protocol the following distances: stem-cement; cement-bone; and stem-bone. All images were printed on hard copies and were read twice. Weighted kappa, kappa(w), analyses were used. The two most frequently loosening regions, stem-cement region 1 and cement-bone region 7, were closely analyzed. In region 1 the five observers had an agreement of 86.75-97.92% between analog and digital images in stem-cement, which is a varied kappa(w) 0.29-0.71. For cement-bone region 7 an agreement of 87.21-90.45% was found, which is a varied kappa(w) of 0.48-0.58. All the kappa values differ significantly from nil. The result shows that digital technique is as good as analog radiographs for diagnosing possible loosening of hip prostheses.}},
  author       = {{Eklund, K. and Jonsson, Kjell and Lindblom, G. and Lundin, Björn and Sanfridsson, J. and Sloth, M. and Sivberg, Bengt}},
  issn         = {{0938-7994}},
  keywords     = {{comparative study; total hip replacement; digital radiographs; analog radiographs}},
  language     = {{eng}},
  number       = {{5}},
  pages        = {{865--869}},
  publisher    = {{Springer}},
  series       = {{European Radiology}},
  title        = {{Are digital images good enough? A comparative study of conventional film-screen vs digital radiographs on printed images of total hip replacement.}},
  url          = {{http://dx.doi.org/10.1007/s00330-003-2126-y}},
  doi          = {{10.1007/s00330-003-2126-y}},
  volume       = {{14}},