Lukkede anaestesisystemer

Reinstrup, Peter LU ; Slots, P and Jorgensen, B C (1992) In Ugeskrift for Læger 154(50). p.3573-3576
Abstract
Anaesthesia with closed anaesthetic systems demands knowledge of the physiology of the patients and of how the various anaesthetic gases behave in the organism as only the gases which the patients produces and absorbs are eliminated and replaced. The system is educational as it provides knowledge of the genuine absorption of oxygen and anaesthetic gases. The method is favourable to the environment as only the gases which are used are supplied and it is thus economical in use although investment in monitoring equipment is necessary. In practice, induction and waking of the patient are complicated with this system and it requires an anaesthetist who constantly adjusts the gases in the circuit.
Please use this url to cite or link to this publication:
author
; and
organization
alternative title
Closed anesthetic systems
publishing date
type
Contribution to journal
publication status
published
subject
in
Ugeskrift for Læger
volume
154
issue
50
pages
3573 - 3576
publisher
Den Almindelige Danske Lægeforening
external identifiers
  • pmid:1471274
  • scopus:0027114653
ISSN
0041-5782
language
Danish
LU publication?
yes
id
16b367ad-7895-4a90-9860-eb4f8d7dd2fa (old id 1106523)
date added to LUP
2016-04-01 15:46:20
date last changed
2021-01-03 06:14:16
@article{16b367ad-7895-4a90-9860-eb4f8d7dd2fa,
  abstract     = {{Anaesthesia with closed anaesthetic systems demands knowledge of the physiology of the patients and of how the various anaesthetic gases behave in the organism as only the gases which the patients produces and absorbs are eliminated and replaced. The system is educational as it provides knowledge of the genuine absorption of oxygen and anaesthetic gases. The method is favourable to the environment as only the gases which are used are supplied and it is thus economical in use although investment in monitoring equipment is necessary. In practice, induction and waking of the patient are complicated with this system and it requires an anaesthetist who constantly adjusts the gases in the circuit.}},
  author       = {{Reinstrup, Peter and Slots, P and Jorgensen, B C}},
  issn         = {{0041-5782}},
  language     = {{dan}},
  number       = {{50}},
  pages        = {{3573--3576}},
  publisher    = {{Den Almindelige Danske Lægeforening}},
  series       = {{Ugeskrift for Læger}},
  title        = {{Lukkede anaestesisystemer}},
  volume       = {{154}},
  year         = {{1992}},
}