The Normal Incidence Monochromator Beamline I3 on MAX III
(2010) 10th International Conference on Synchrotron Radiation Instrumentation 1234. p.661-664- Abstract
- On the 700 MeV MAX III ring at MAX-lab, a 6.65 m off-axis eagle type monochromator beamline has recently been commissioned. The beamline is sourced by an apple type variable polarization undulator. The energy range of the beamline is 4.6-50 eV and the resolving power achieved is more than 100,000. There are two branch lines, one for angle and spin resolved photoemission studies from solids and the other for gas phase and luminescence experiments. We present the design and performance of the beamline.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1752667
- author
- organization
- publishing date
- 2010
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- keywords
- Circular polarization, Monochromator, Normal Incidence
- host publication
- AIP Conference Proceedings
- volume
- 1234
- pages
- 661 - 664
- publisher
- American Institute of Physics (AIP)
- conference name
- 10th International Conference on Synchrotron Radiation Instrumentation
- conference location
- Melbourne, Australia
- conference dates
- 2009-09-27 - 2009-10-02
- external identifiers
-
- wos:000283705500148
- scopus:77955028871
- ISSN
- 1551-7616
- 0094-243X
- DOI
- 10.1063/1.3463293
- language
- English
- LU publication?
- yes
- id
- 0da20949-9715-46d4-a477-42a472321c11 (old id 1752667)
- date added to LUP
- 2016-04-01 09:50:42
- date last changed
- 2025-01-13 23:32:16
@inproceedings{0da20949-9715-46d4-a477-42a472321c11, abstract = {{On the 700 MeV MAX III ring at MAX-lab, a 6.65 m off-axis eagle type monochromator beamline has recently been commissioned. The beamline is sourced by an apple type variable polarization undulator. The energy range of the beamline is 4.6-50 eV and the resolving power achieved is more than 100,000. There are two branch lines, one for angle and spin resolved photoemission studies from solids and the other for gas phase and luminescence experiments. We present the design and performance of the beamline.}}, author = {{Thiagarajan, Balasubramanian and Jensen, Brian Norsk and Urpelainen, S. and Sommarin, Bengt and Johansson, Ulf and Huttula, M. and Sankari, Rami and Nommiste, E. and Aksela, S. and Aksela, H. and Nyholm, Ralf}}, booktitle = {{AIP Conference Proceedings}}, issn = {{1551-7616}}, keywords = {{Circular polarization; Monochromator; Normal Incidence}}, language = {{eng}}, pages = {{661--664}}, publisher = {{American Institute of Physics (AIP)}}, title = {{The Normal Incidence Monochromator Beamline I3 on MAX III}}, url = {{http://dx.doi.org/10.1063/1.3463293}}, doi = {{10.1063/1.3463293}}, volume = {{1234}}, year = {{2010}}, }