PIXE Detection Limits for some Aerosol Collection Substrates by Excitation with protons and 4He2+ Ions from a 3 MV Tandem Accelerator
(1984) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms p.441-445- Abstract
- Comparisons of PIXE detection limits for K, X rays using 2-5 MeV protons and 7-8 MeV 4He2+ ions as projectiles have been
performed. The comparisons have been made for common aerosol backings. According to simple theoretical considerations regarding
X-ray production cross sections and the production of background radiation, detection limits for 4He2+ should be two to four times
lower than for protons for equal vefoeity projectiles of equal numbers. However, the background in X-ray spectra arising from gamma-quanta being Compton scattered in the Si(Li) detector can strongIy affect the detection limits. The detection limits using protons and
4HeZ+ ions from a 3 MV electrostatic tandem accelerator are... (More) - Comparisons of PIXE detection limits for K, X rays using 2-5 MeV protons and 7-8 MeV 4He2+ ions as projectiles have been
performed. The comparisons have been made for common aerosol backings. According to simple theoretical considerations regarding
X-ray production cross sections and the production of background radiation, detection limits for 4He2+ should be two to four times
lower than for protons for equal vefoeity projectiles of equal numbers. However, the background in X-ray spectra arising from gamma-quanta being Compton scattered in the Si(Li) detector can strongIy affect the detection limits. The detection limits using protons and
4HeZ+ ions from a 3 MV electrostatic tandem accelerator are determined and discussed. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1787184
- author
- Swietlicki, Erik LU and Bohgard, Mats LU
- organization
- publishing date
- 1984
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- PIXE, Aerosol, Detection Limits
- in
- Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms
- issue
- 1084
- pages
- 441 - 445
- publisher
- Elsevier
- external identifiers
-
- scopus:48749138527
- ISSN
- 0168-583X
- DOI
- 10.1016/0168-583X(84)90414-2
- language
- English
- LU publication?
- yes
- additional info
- The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Ergonomics and Aerosol Technology (011025002), Nuclear Physics (Faculty of Technology) (011013007)
- id
- f1227e82-abbb-4ae4-a5b4-a01d3bf799b3 (old id 1787184)
- date added to LUP
- 2016-04-01 15:58:12
- date last changed
- 2021-01-03 11:14:30
@article{f1227e82-abbb-4ae4-a5b4-a01d3bf799b3, abstract = {{Comparisons of PIXE detection limits for K, X rays using 2-5 MeV protons and 7-8 MeV 4He2+ ions as projectiles have been<br/><br> performed. The comparisons have been made for common aerosol backings. According to simple theoretical considerations regarding<br/><br> X-ray production cross sections and the production of background radiation, detection limits for 4He2+ should be two to four times<br/><br> lower than for protons for equal vefoeity projectiles of equal numbers. However, the background in X-ray spectra arising from gamma-quanta being Compton scattered in the Si(Li) detector can strongIy affect the detection limits. The detection limits using protons and<br/><br> 4HeZ+ ions from a 3 MV electrostatic tandem accelerator are determined and discussed.}}, author = {{Swietlicki, Erik and Bohgard, Mats}}, issn = {{0168-583X}}, keywords = {{PIXE; Aerosol; Detection Limits}}, language = {{eng}}, number = {{1084}}, pages = {{441--445}}, publisher = {{Elsevier}}, series = {{Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms}}, title = {{PIXE Detection Limits for some Aerosol Collection Substrates by Excitation with protons and 4He2+ Ions from a 3 MV Tandem Accelerator}}, url = {{https://lup.lub.lu.se/search/files/4529244/1787186.pdf}}, doi = {{10.1016/0168-583X(84)90414-2}}, year = {{1984}}, }