Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Monte Carlo simulation of the photon-tagger focal-plane electronics at the MAX IV laboratory

Myers, L. S. ; Feldman, G. ; Fissum, Kevin LU orcid ; Isaksson, Lennart LU ; Kovash, M. A. ; Nathan, A. M. ; Pywell, R. E. and Schröder, Bent LU (2013) In Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment 729. p.707-717
Abstract
Rate-dependent effects in the electronics used to instrument the tagger focal plane at the MAX IV Laboratory have been investigated using the novel approach of Monte Carlo simulation. Results are compared to analytical calculations as well as experimental data for both specialized testing and production running to demonstrate a thorough understanding of the behavior of the detector system.(C) 2013 Elsevier By. All rights reserved.
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Tagger hodoscope, Electronics simulation, Rate dependencies
in
Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment
volume
729
pages
707 - 717
publisher
Elsevier
external identifiers
  • wos:000325753500088
  • scopus:84883891468
ISSN
0167-5087
DOI
10.1016/j.nima.2013.08.032
project
Elastic and Virtual Compton Scattering and Nucleon Polarizabilities
Development of Radiation Detectors and Radiation-Detection Techniques
language
English
LU publication?
yes
id
2108b03b-6c00-4ed0-9a1e-8c839b419c90 (old id 4157921)
date added to LUP
2016-04-01 14:25:57
date last changed
2022-02-27 02:39:22
@article{2108b03b-6c00-4ed0-9a1e-8c839b419c90,
  abstract     = {{Rate-dependent effects in the electronics used to instrument the tagger focal plane at the MAX IV Laboratory have been investigated using the novel approach of Monte Carlo simulation. Results are compared to analytical calculations as well as experimental data for both specialized testing and production running to demonstrate a thorough understanding of the behavior of the detector system.(C) 2013 Elsevier By. All rights reserved.}},
  author       = {{Myers, L. S. and Feldman, G. and Fissum, Kevin and Isaksson, Lennart and Kovash, M. A. and Nathan, A. M. and Pywell, R. E. and Schröder, Bent}},
  issn         = {{0167-5087}},
  keywords     = {{Tagger hodoscope; Electronics simulation; Rate dependencies}},
  language     = {{eng}},
  pages        = {{707--717}},
  publisher    = {{Elsevier}},
  series       = {{Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment}},
  title        = {{Monte Carlo simulation of the photon-tagger focal-plane electronics at the MAX IV laboratory}},
  url          = {{http://dx.doi.org/10.1016/j.nima.2013.08.032}},
  doi          = {{10.1016/j.nima.2013.08.032}},
  volume       = {{729}},
  year         = {{2013}},
}