Islanding and Reconnection of Converter Based Distributed Generation Systems
(2006) Norpie 2006- Abstract
- In this paper a method for reconnecting islanded distributed generation systems is presented. Islanding of a distributed generation system may result from a fault or malfunction of protective elements. The behavior of local voltage and frequency control in case of islanding is investigated. A method for reconnecting the distributed generation system and the behavior of voltage and frequency control in case of reconnection are also investigated. It is found that islanding and reconnection with preserved voltage and frequency control is possible also in the case of local control without communication. Still communication of low bandwidth is required for the reconnection scheme presented here. The method presented is verified in simulations.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/2628333
- author
- Karlsson, Per LU
- organization
- publishing date
- 2006
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- keywords
- Islanding, reconnection, distributed generation
- host publication
- Norpie 2006 conference proceedings
- pages
- 6 pages
- publisher
- EPE Association
- conference name
- Norpie 2006
- conference location
- Lund, Sweden
- conference dates
- 2006-06-12 - 2006-06-14
- language
- English
- LU publication?
- yes
- id
- bbcb3e21-d505-4086-984c-329b4ed8fb7e (old id 2628333)
- alternative location
- https://www.epe-association.org/epe/users/documents.download.php?type=download&documents_id=8575
- date added to LUP
- 2016-04-04 11:41:05
- date last changed
- 2018-11-21 21:06:30
@inproceedings{bbcb3e21-d505-4086-984c-329b4ed8fb7e, abstract = {{In this paper a method for reconnecting islanded distributed generation systems is presented. Islanding of a distributed generation system may result from a fault or malfunction of protective elements. The behavior of local voltage and frequency control in case of islanding is investigated. A method for reconnecting the distributed generation system and the behavior of voltage and frequency control in case of reconnection are also investigated. It is found that islanding and reconnection with preserved voltage and frequency control is possible also in the case of local control without communication. Still communication of low bandwidth is required for the reconnection scheme presented here. The method presented is verified in simulations.}}, author = {{Karlsson, Per}}, booktitle = {{Norpie 2006 conference proceedings}}, keywords = {{Islanding; reconnection; distributed generation}}, language = {{eng}}, publisher = {{EPE Association}}, title = {{Islanding and Reconnection of Converter Based Distributed Generation Systems}}, url = {{https://www.epe-association.org/epe/users/documents.download.php?type=download&documents_id=8575}}, year = {{2006}}, }