Influence of Nonuniform Channel Width Distribution in Porous Silicon High Aspect Ratio Parallel Channel Micro Reactors
(2005) 8th International Conference on Miniaturized System in Chemistry and Life Science 1. p.629-631- Abstract
- The paper focuses on the fact that, since the flow rate in parallel channels relies strongly on the channel width, the combination may lead to inaccurate results if errors in the fabrication process lead to an uneven distribution of channel widths. Parallel channel enzyme reactors were designed with channel widths distributed normally with different degrees of standard deviation. The reactors were then evaluated with regard to dispersion and to catalytic effect of the immobilised enzyme. It was shown that for lower concentrations the catalytic efficiency decreased significantly even for small variations in the distribution of channel widths and reactors with poor homogeneity in channel widths also diluted the sample more than the others.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/785885
- author
- Bengtsson, Martin LU ; Evander, Mikael LU and Laurell, Thomas LU
- organization
- publishing date
- 2005
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- keywords
- dispersion, IMER, keywords: microreactor, porous silicon
- host publication
- [Host publication title missing]
- editor
- Laurell, Thomas ; Nilsson, Johan ; Jensen, Klavs F. ; Harrison, D. Jed and Kutter, Jörg P.
- volume
- 1
- pages
- 3 pages
- publisher
- Royal Society of Chemistry
- conference name
- 8th International Conference on Miniaturized System in Chemistry and Life Science
- conference location
- Malmö, Sweden
- conference dates
- 2004-09-26 - 2004-09-30
- external identifiers
-
- wos:000228997000211
- ISBN
- 0-85404-643-7
- language
- English
- LU publication?
- yes
- id
- 305c0da5-552b-4999-b65d-a4653a716e35 (old id 785885)
- date added to LUP
- 2016-04-04 10:34:37
- date last changed
- 2018-11-21 20:59:34
@inproceedings{305c0da5-552b-4999-b65d-a4653a716e35, abstract = {{The paper focuses on the fact that, since the flow rate in parallel channels relies strongly on the channel width, the combination may lead to inaccurate results if errors in the fabrication process lead to an uneven distribution of channel widths. Parallel channel enzyme reactors were designed with channel widths distributed normally with different degrees of standard deviation. The reactors were then evaluated with regard to dispersion and to catalytic effect of the immobilised enzyme. It was shown that for lower concentrations the catalytic efficiency decreased significantly even for small variations in the distribution of channel widths and reactors with poor homogeneity in channel widths also diluted the sample more than the others.}}, author = {{Bengtsson, Martin and Evander, Mikael and Laurell, Thomas}}, booktitle = {{[Host publication title missing]}}, editor = {{Laurell, Thomas and Nilsson, Johan and Jensen, Klavs F. and Harrison, D. Jed and Kutter, Jörg P.}}, isbn = {{0-85404-643-7}}, keywords = {{dispersion; IMER; keywords: microreactor; porous silicon}}, language = {{eng}}, pages = {{629--631}}, publisher = {{Royal Society of Chemistry}}, title = {{Influence of Nonuniform Channel Width Distribution in Porous Silicon High Aspect Ratio Parallel Channel Micro Reactors}}, volume = {{1}}, year = {{2005}}, }