The charge state distribution of a carbon beam measured at the lund pelletron accelerator with the newly installed terminal pumping system in use
(2002) In Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment 481(1-3). p.1-8- Abstract
- Charge state distributions for (12) C and C-13 ions have been measured at the Lund Pelletron tandem accelerator for the N-2 gas stripper with a newly installed terminal pumping system in use. A comparison of the results obtained for the ion energies between 1.5 and 2.8 MeV with the foil stripper and the gas stripper without terminal pumping demonstrates the great improvement of the stripping process achieved with the new terminal pumping. (C) 2002 Elsevier Science B.V. All rights reserved.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/337764
- author
- Kiisk, Madis LU ; Erlandsson, Bengt LU ; Faarinen, Mikko LU ; Hellborg, Ragnar LU ; Hakansson, K ; Persson, Per LU ; Skog, Göran LU and Stenström, Kristina LU
- organization
- publishing date
- 2002
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment
- volume
- 481
- issue
- 1-3
- pages
- 1 - 8
- publisher
- Elsevier
- external identifiers
-
- wos:000175502700001
- scopus:0036534083
- ISSN
- 0167-5087
- DOI
- 10.1016/S0168-9002(01)01255-4
- language
- English
- LU publication?
- yes
- id
- 221131e7-ed2a-401d-b702-9d76cf8d4580 (old id 337764)
- date added to LUP
- 2016-04-01 15:18:45
- date last changed
- 2022-01-28 04:43:13
@article{221131e7-ed2a-401d-b702-9d76cf8d4580, abstract = {{Charge state distributions for (12) C and C-13 ions have been measured at the Lund Pelletron tandem accelerator for the N-2 gas stripper with a newly installed terminal pumping system in use. A comparison of the results obtained for the ion energies between 1.5 and 2.8 MeV with the foil stripper and the gas stripper without terminal pumping demonstrates the great improvement of the stripping process achieved with the new terminal pumping. (C) 2002 Elsevier Science B.V. All rights reserved.}}, author = {{Kiisk, Madis and Erlandsson, Bengt and Faarinen, Mikko and Hellborg, Ragnar and Hakansson, K and Persson, Per and Skog, Göran and Stenström, Kristina}}, issn = {{0167-5087}}, language = {{eng}}, number = {{1-3}}, pages = {{1--8}}, publisher = {{Elsevier}}, series = {{Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment}}, title = {{The charge state distribution of a carbon beam measured at the lund pelletron accelerator with the newly installed terminal pumping system in use}}, url = {{http://dx.doi.org/10.1016/S0168-9002(01)01255-4}}, doi = {{10.1016/S0168-9002(01)01255-4}}, volume = {{481}}, year = {{2002}}, }