Wegdén, Marie LU ; Elfman, Mikael LU ; Kristiansson, Per LU ; Arteaga, Natalia LU ; Auzelyte, Vaida LU ; Malmqvist, Klas LU ; Nilsson, Charlotta LU and Pallon, Jan LU (2006) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 249(1-2). p.756-759
Abstract
A system for ion beam tomography has been implemented in conjunction with the new sub-micron bearriline at the Lund Nuclear Microprobe laboratory. The first version of the system is dedicated to STIM (scanning transmission ion microscopy) tomography for three-dimensional mass density analysis, but future development will allow also PIXE (particle induced X-ray emission) tomography for elemental analysis of micrometer-sized samples. The PIXE tomography will gain from the 8-element large area HPGe X-ray detector (100 mm(2) for each element) at the low beam currents inherited with a sub-micrometer beam spot size. In this work, the first results are presented together with a detailed description of the developed system, including computer... (More)
A system for ion beam tomography has been implemented in conjunction with the new sub-micron bearriline at the Lund Nuclear Microprobe laboratory. The first version of the system is dedicated to STIM (scanning transmission ion microscopy) tomography for three-dimensional mass density analysis, but future development will allow also PIXE (particle induced X-ray emission) tomography for elemental analysis of micrometer-sized samples. The PIXE tomography will gain from the 8-element large area HPGe X-ray detector (100 mm(2) for each element) at the low beam currents inherited with a sub-micrometer beam spot size. In this work, the first results are presented together with a detailed description of the developed system, including computer control of the sample rotation. The reconstruction technique, as well as potential tomography applications is briefly discussed. (Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
tomography, filtered backprojection, nuclear microprobe, STIM
in
Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms
volume
249
issue
1-2
pages
756 - 759
publisher
Elsevier
external identifiers
  • wos:000239545000183
  • scopus:33745820348
ISSN
0168-583X
DOI
10.1016/j.nimb.2006.03.133
language
English
LU publication?
yes
additional info
The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Nuclear Physics (Faculty of Technology) (011013007)
id
924baf76-22cd-4c83-bc5f-2ff3f55e8a02 (old id 398284)
date added to LUP
2016-04-01 16:52:32
date last changed
2022-01-28 22:44:54
@article{924baf76-22cd-4c83-bc5f-2ff3f55e8a02,
  abstract     = {{A system for ion beam tomography has been implemented in conjunction with the new sub-micron bearriline at the Lund Nuclear Microprobe laboratory. The first version of the system is dedicated to STIM (scanning transmission ion microscopy) tomography for three-dimensional mass density analysis, but future development will allow also PIXE (particle induced X-ray emission) tomography for elemental analysis of micrometer-sized samples. The PIXE tomography will gain from the 8-element large area HPGe X-ray detector (100 mm(2) for each element) at the low beam currents inherited with a sub-micrometer beam spot size. In this work, the first results are presented together with a detailed description of the developed system, including computer control of the sample rotation. The reconstruction technique, as well as potential tomography applications is briefly discussed.}},
  author       = {{Wegdén, Marie and Elfman, Mikael and Kristiansson, Per and Arteaga, Natalia and Auzelyte, Vaida and Malmqvist, Klas and Nilsson, Charlotta and Pallon, Jan}},
  issn         = {{0168-583X}},
  keywords     = {{tomography; filtered backprojection; nuclear microprobe; STIM}},
  language     = {{eng}},
  number       = {{1-2}},
  pages        = {{756--759}},
  publisher    = {{Elsevier}},
  series       = {{Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms}},
  title        = {{Development of a microtomography system at the Lund sub-micron beamline}},
  url          = {{http://dx.doi.org/10.1016/j.nimb.2006.03.133}},
  doi          = {{10.1016/j.nimb.2006.03.133}},
  volume       = {{249}},
  year         = {{2006}},
}