Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Fluorescence lidar imaging of fungal growth on high-voltage outdoor composite insulators

Bengtsson, Magnus LU ; Grönlund, Rasmus LU ; Sjöholm, Mikael LU ; Abrahamsson, Christoffer LU ; Dernfalk, AD ; Wallstrom, S ; Larsson, A ; Weibring, P ; Karlsson, S and Gubanski, SM , et al. (2005) In Optics and Lasers in Engineering 43(6). p.624-632
Abstract
Remote fluorescence imaging of fungal growth on polymeric high-voltage insulators was performed using a mobile lidar system with a laser wavelength of 355 nm. Insulator areas contaminated by fungal growth could be distinguished from clean surfaces and readily be imaged. The experiments were supported by detailed spectral studies performed in laboratory using a fibre-optic fluorosensor incorporating an optical multi-channel analyser system (OMA) and a nitrogen laser emitting radiation at 33 7 nm.
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; ; ; and , et al. (More)
; ; ; ; ; ; ; ; ; ; and (Less)
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
remote sensing, fluorescence, polymeric insulators, lidar, fungal growth
in
Optics and Lasers in Engineering
volume
43
issue
6
pages
624 - 632
publisher
Elsevier
external identifiers
  • wos:000227961800002
  • scopus:13844299424
ISSN
0143-8166
DOI
10.1016/j.optlaseng.2004.09.019
language
English
LU publication?
yes
id
3c2edf31-a412-49ad-9c7e-79bb5e355d73 (old id 246993)
date added to LUP
2016-04-01 11:48:26
date last changed
2022-04-13 01:35:28
@article{3c2edf31-a412-49ad-9c7e-79bb5e355d73,
  abstract     = {{Remote fluorescence imaging of fungal growth on polymeric high-voltage insulators was performed using a mobile lidar system with a laser wavelength of 355 nm. Insulator areas contaminated by fungal growth could be distinguished from clean surfaces and readily be imaged. The experiments were supported by detailed spectral studies performed in laboratory using a fibre-optic fluorosensor incorporating an optical multi-channel analyser system (OMA) and a nitrogen laser emitting radiation at 33 7 nm.}},
  author       = {{Bengtsson, Magnus and Grönlund, Rasmus and Sjöholm, Mikael and Abrahamsson, Christoffer and Dernfalk, AD and Wallstrom, S and Larsson, A and Weibring, P and Karlsson, S and Gubanski, SM and Kröll, Stefan and Svanberg, Sune}},
  issn         = {{0143-8166}},
  keywords     = {{remote sensing; fluorescence; polymeric insulators; lidar; fungal growth}},
  language     = {{eng}},
  number       = {{6}},
  pages        = {{624--632}},
  publisher    = {{Elsevier}},
  series       = {{Optics and Lasers in Engineering}},
  title        = {{Fluorescence lidar imaging of fungal growth on high-voltage outdoor composite insulators}},
  url          = {{https://lup.lub.lu.se/search/files/2650361/2376700.pdf}},
  doi          = {{10.1016/j.optlaseng.2004.09.019}},
  volume       = {{43}},
  year         = {{2005}},
}