Aortic valve and coronary artery calcium scoring : impact of half- versus standard-dose protocols

Mantini, Cesare ; Cademartiri, Filippo ; Procaccini, Luca ; Tana, Claudio ; Mastrodicasa, Domenico ; Saba, Luca ; Gallina, Sabina ; Tana, Marco ; Caulo, Massimo and Ricci, Fabrizio LU (2025) In Radiologia Medica 130(9). p.1352-1362
Abstract

Aims: CT acquisition parameters and reconstruction techniques may affect the accuracy of calcium scoring measurements with a potential impact on clinical decision making. We evaluated the agreement of half- versus standard-dose protocols for assessment of aortic valve (AVCS HD and AVCS SD protocols) and coronary artery calcium scoring (CACS HD and CACS SD protocols) with and without the application of iterative reconstruction. Methods: We enrolled 144 consecutive patients (mean age 83 ± 9 years) with known aortic stenosis undergoing 128-row prospective sequential CT with standard (120 kVp/20 mAs) and half-dose (120 kVp/10 mAs) protocols for both AVCS and CACS evaluation. The half-dose dataset was processed with and without iterative... (More)

Aims: CT acquisition parameters and reconstruction techniques may affect the accuracy of calcium scoring measurements with a potential impact on clinical decision making. We evaluated the agreement of half- versus standard-dose protocols for assessment of aortic valve (AVCS HD and AVCS SD protocols) and coronary artery calcium scoring (CACS HD and CACS SD protocols) with and without the application of iterative reconstruction. Methods: We enrolled 144 consecutive patients (mean age 83 ± 9 years) with known aortic stenosis undergoing 128-row prospective sequential CT with standard (120 kVp/20 mAs) and half-dose (120 kVp/10 mAs) protocols for both AVCS and CACS evaluation. The half-dose dataset was processed with and without iterative reconstruction. Agreement and precision of different protocols were evaluated using linear regression and Bland–Altman analysis. Additionally, we assessed the reclassification of cardiovascular risk based on the Mayo Clinic system and the likelihood of severe aortic stenosis using sex-specific categories. Results: Compared with the standard dose, the half-dose protocol with or without iterative reconstruction demonstrated optimum agreement for the evaluation of AVCS (r = 0.99; R2 = 0.97) and CACS (r = 0.96; R2 = 0.93). The half-dose iterative reconstruction protocol yielded a very low rate of reclassification aortic stenosis severity (1.4%) and cardiovascular risk (6.2%). The half-dose protocol resulted in 47.5% radiation dose reduction compared to standard dose (dose-length product: 8.5 ± 1.1 vs. 17.9 ± 2.7; p < 0.001). Conclusions: Our findings suggest that the half-dose protocol with iterative reconstruction provides reliable and accurate results for both AVCS and CACS assessment. This evidence underscores the potential to optimize radiation dose while preserving the precision of diagnostic outcomes, thereby minimally impacting clinical management.

(Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Aortic valve calcium scoring, Cardiovascular risk, Coronary artery calcium scoring, Half-dose protocol, Iterative reconstruction, Low radiation dose
in
Radiologia Medica
volume
130
issue
9
pages
11 pages
publisher
Springer-Verlag Italia s.r.l.
external identifiers
  • pmid:40481896
  • scopus:105007793916
ISSN
0033-8362
DOI
10.1007/s11547-025-02027-6
language
English
LU publication?
yes
additional info
Publisher Copyright: © Italian Society of Medical Radiology 2025.
id
3f2237f7-320f-4f2f-911c-85e97dde2150
date added to LUP
2026-01-29 14:17:11
date last changed
2026-01-29 14:18:25
@article{3f2237f7-320f-4f2f-911c-85e97dde2150,
  abstract     = {{<p>Aims: CT acquisition parameters and reconstruction techniques may affect the accuracy of calcium scoring measurements with a potential impact on clinical decision making. We evaluated the agreement of half- versus standard-dose protocols for assessment of aortic valve (AVCS HD and AVCS SD protocols) and coronary artery calcium scoring (CACS HD and CACS SD protocols) with and without the application of iterative reconstruction. Methods: We enrolled 144 consecutive patients (mean age 83 ± 9 years) with known aortic stenosis undergoing 128-row prospective sequential CT with standard (120 kVp/20 mAs) and half-dose (120 kVp/10 mAs) protocols for both AVCS and CACS evaluation. The half-dose dataset was processed with and without iterative reconstruction. Agreement and precision of different protocols were evaluated using linear regression and Bland–Altman analysis. Additionally, we assessed the reclassification of cardiovascular risk based on the Mayo Clinic system and the likelihood of severe aortic stenosis using sex-specific categories. Results: Compared with the standard dose, the half-dose protocol with or without iterative reconstruction demonstrated optimum agreement for the evaluation of AVCS (r = 0.99; R<sup>2</sup> = 0.97) and CACS (r = 0.96; R<sup>2</sup> = 0.93). The half-dose iterative reconstruction protocol yielded a very low rate of reclassification aortic stenosis severity (1.4%) and cardiovascular risk (6.2%). The half-dose protocol resulted in 47.5% radiation dose reduction compared to standard dose (dose-length product: 8.5 ± 1.1 vs. 17.9 ± 2.7; p &lt; 0.001). Conclusions: Our findings suggest that the half-dose protocol with iterative reconstruction provides reliable and accurate results for both AVCS and CACS assessment. This evidence underscores the potential to optimize radiation dose while preserving the precision of diagnostic outcomes, thereby minimally impacting clinical management.</p>}},
  author       = {{Mantini, Cesare and Cademartiri, Filippo and Procaccini, Luca and Tana, Claudio and Mastrodicasa, Domenico and Saba, Luca and Gallina, Sabina and Tana, Marco and Caulo, Massimo and Ricci, Fabrizio}},
  issn         = {{0033-8362}},
  keywords     = {{Aortic valve calcium scoring; Cardiovascular risk; Coronary artery calcium scoring; Half-dose protocol; Iterative reconstruction; Low radiation dose}},
  language     = {{eng}},
  number       = {{9}},
  pages        = {{1352--1362}},
  publisher    = {{Springer-Verlag Italia s.r.l.}},
  series       = {{Radiologia Medica}},
  title        = {{Aortic valve and coronary artery calcium scoring : impact of half- versus standard-dose protocols}},
  url          = {{http://dx.doi.org/10.1007/s11547-025-02027-6}},
  doi          = {{10.1007/s11547-025-02027-6}},
  volume       = {{130}},
  year         = {{2025}},
}