Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Beta and Alpha Particle Autoradiography

Örbom, Anders LU ; Miller, Brian W and Bäck, Tom (2022) In Series in Medical Physics and Biomedical Engineering 1. p.563-587
Abstract
utoradiography is defined as technologies and methods used to produce a two-dimensional image of the distribution of activity in, or on, a thin and solid sample that is in close proximity to the detector. The images are usually formed by charged particles (α or β±), and image characteristics are determined both by the detector and the properties of the particles detected. This method is not widely employed in the clinic, but in a number of research settings such as pharmaceutical development. The application of the method can be done either ex vivo using tissue from animal models, or in vitro where the radiotracer is applied to tissue samples post sacrifice. This chapter will primarily discuss different detection systems used for... (More)
utoradiography is defined as technologies and methods used to produce a two-dimensional image of the distribution of activity in, or on, a thin and solid sample that is in close proximity to the detector. The images are usually formed by charged particles (α or β±), and image characteristics are determined both by the detector and the properties of the particles detected. This method is not widely employed in the clinic, but in a number of research settings such as pharmaceutical development. The application of the method can be done either ex vivo using tissue from animal models, or in vitro where the radiotracer is applied to tissue samples post sacrifice. This chapter will primarily discuss different detection systems used for autoradiography, beginning with the classical film emulsion and continuing to detail phosphor storage plates, scintillation-based detectors, gaseous detectors, and semiconductor-based imaging systems. A special focus is also made on detectors being capable of imaging alpha-particles. For each type of detector, applications of the system are presented from recent academic work to show the possibilities of using autoradiography to produce scientific data.
(Less)
Abstract (Swedish)
Bokkapitel i Handbook of Nuclear Medicine and Molecular Imaging for Physicists
Please use this url to cite or link to this publication:
author
; and
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
host publication
Handbook of Nuclear Medicine and Molecular Imaging for Physicists : Instrumentation and Imaging Procedures - Instrumentation and Imaging Procedures
series title
Series in Medical Physics and Biomedical Engineering
editor
Ljungberg, Michael
volume
1
edition
1
pages
25 pages
publisher
CRC Press
ISBN
9781138593268
9780429489556
language
English
LU publication?
yes
id
3f264c14-5eda-4c96-8e38-5a63ca1d8ac2
date added to LUP
2021-10-14 23:55:39
date last changed
2023-05-26 10:15:44
@inbook{3f264c14-5eda-4c96-8e38-5a63ca1d8ac2,
  abstract     = {{utoradiography is defined as technologies and methods used to produce a two-dimensional image of the distribution of activity in, or on, a thin and solid sample that is in close proximity to the detector. The images are usually formed by charged particles (α or β±), and image characteristics are determined both by the detector and the properties of the particles detected. This method is not widely employed in the clinic, but in a number of research settings such as pharmaceutical development. The application of the method can be done either ex vivo using tissue from animal models, or in vitro where the radiotracer is applied to tissue samples post sacrifice. This chapter will primarily discuss different detection systems used for autoradiography, beginning with the classical film emulsion and continuing to detail phosphor storage plates, scintillation-based detectors, gaseous detectors, and semiconductor-based imaging systems. A special focus is also made on detectors being capable of imaging alpha-particles. For each type of detector, applications of the system are presented from recent academic work to show the possibilities of using autoradiography to produce scientific data.<br/>}},
  author       = {{Örbom, Anders and Miller, Brian W and Bäck, Tom}},
  booktitle    = {{Handbook of Nuclear Medicine and Molecular Imaging for Physicists : Instrumentation and Imaging Procedures}},
  editor       = {{Ljungberg, Michael}},
  isbn         = {{9781138593268}},
  language     = {{eng}},
  month        = {{04}},
  pages        = {{563--587}},
  publisher    = {{CRC Press}},
  series       = {{Series in Medical Physics and Biomedical Engineering}},
  title        = {{Beta and Alpha Particle Autoradiography}},