Sampling and Selective Detection of Peptides and Proteins Emphazing Microdialysis,Bio-recognition Assays and MALDI-TOF MS
(2000)- Abstract
- The use of microdialysis sampling and flow immunochemical detection as well as MALDI-TOF MS for peptide and protein analysis is described. Sampling of peptides and smaller proteins was investigated with different membranes. Cyclodextrines additives and an on-line push-pull microdialysis sampling method was used with the result of a higher sampling efficiency compared to conventional microdialysis sampling.
Real-time flow immuno assays systems were developed for the quantification of Interleukin-8 and Interleukin10 in cell samples. Optimisation with regards to affinity support selection as well as carrier buffer composition were performed.
Connection of capillary LC with MALDI-TOF MS was made utilising... (More) - The use of microdialysis sampling and flow immunochemical detection as well as MALDI-TOF MS for peptide and protein analysis is described. Sampling of peptides and smaller proteins was investigated with different membranes. Cyclodextrines additives and an on-line push-pull microdialysis sampling method was used with the result of a higher sampling efficiency compared to conventional microdialysis sampling.
Real-time flow immuno assays systems were developed for the quantification of Interleukin-8 and Interleukin10 in cell samples. Optimisation with regards to affinity support selection as well as carrier buffer composition were performed.
Connection of capillary LC with MALDI-TOF MS was made utilising an m-dispenser technique enabling sample handling of picoliter volumes. A novel sample preparation technique for the uniform coating of MALDI targets was developed. (Less) - Abstract (Swedish)
- Popular Abstract in Swedish
Inom analytisk kemi används en rad metoder för att erhålla separation mellan de ämnen man vill studera. Detta är ofta nödvändigt om man vill ta reda på specifika egenskaper i ett biologiskt prov. Naturen har utvecklat sofistikerade verktyg t.ex. antikroppar som även kan användas för att separera ett specifikt ämne. Inom mitt doktorsarbete har antikroppar fyllt en viktig funktion vid igenkännande av specifika proteiner i en komplex blandning. Antikropps baserade analytiska system har utvecklats för att mäta proteiner i real-tid.
Mikrodialys är en provtagningsteknik som kan användas för många olika ämnen. Separationen baserar sig på ett membrans förmåga att släppa igenom ämnen... (More) - Popular Abstract in Swedish
Inom analytisk kemi används en rad metoder för att erhålla separation mellan de ämnen man vill studera. Detta är ofta nödvändigt om man vill ta reda på specifika egenskaper i ett biologiskt prov. Naturen har utvecklat sofistikerade verktyg t.ex. antikroppar som även kan användas för att separera ett specifikt ämne. Inom mitt doktorsarbete har antikroppar fyllt en viktig funktion vid igenkännande av specifika proteiner i en komplex blandning. Antikropps baserade analytiska system har utvecklats för att mäta proteiner i real-tid.
Mikrodialys är en provtagningsteknik som kan användas för många olika ämnen. Separationen baserar sig på ett membrans förmåga att släppa igenom ämnen (permeabilitet). Olika membran har testats för provtagning av peptider och proteiner. För att kunna mäta mängden av de enskilda proteinerna har provtagningstekniken kombinerats med ett vätskekromatografiskt system. Vid utvecklande av dessa system har automation varit ett viktigt mål.
Proteiner och peptider har studerats mera ingående med hjälp av en mass spektrometri teknik som heter MALDI. För att erhålla mer specifik information har vätskekromatografi kombinerats med MALDI. I detta arbete har en mikrodispenser (en miniatyriserad vätskefördelare liknande skrivarhuvudet i bläckstråleskrivare) använts för att transformera analyterna ifrån en vätske fas till fast fas på ett enkelt, automatiskt och mycket reproducerbart sätt. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/40962
- author
- Kjellström, Sven LU
- supervisor
- opponent
-
- Andren, Per
- organization
- publishing date
- 2000
- type
- Thesis
- publication status
- published
- subject
- keywords
- cyclodextrines, protein identification, m-dispenser, push-pull microdialysis, microdialysis sampling, MALDI-TOF MS, Interleukin-8, Flow immuno assays, Interleukin-10, Analytical chemistry, Analytisk kemi
- pages
- 196 pages
- publisher
- Analytical Chemistry, Lund University
- defense location
- Lecture Hall B Chemical Center
- defense date
- 2000-11-17 13:15:00
- external identifiers
-
- other:LUNKDL/NKAK-1056 1-196 (2000)
- ISBN
- 91-7874-077-0
- language
- English
- LU publication?
- yes
- additional info
- The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Analytical Chemistry (S/LTH) (011001004)
- id
- a98e083e-26f6-4d02-9184-2a7e84f07e63 (old id 40962)
- date added to LUP
- 2016-04-04 10:36:21
- date last changed
- 2018-11-21 20:59:44
@phdthesis{a98e083e-26f6-4d02-9184-2a7e84f07e63, abstract = {{The use of microdialysis sampling and flow immunochemical detection as well as MALDI-TOF MS for peptide and protein analysis is described. Sampling of peptides and smaller proteins was investigated with different membranes. Cyclodextrines additives and an on-line push-pull microdialysis sampling method was used with the result of a higher sampling efficiency compared to conventional microdialysis sampling.<br/><br> <br/><br> Real-time flow immuno assays systems were developed for the quantification of Interleukin-8 and Interleukin10 in cell samples. Optimisation with regards to affinity support selection as well as carrier buffer composition were performed.<br/><br> <br/><br> Connection of capillary LC with MALDI-TOF MS was made utilising an m-dispenser technique enabling sample handling of picoliter volumes. A novel sample preparation technique for the uniform coating of MALDI targets was developed.}}, author = {{Kjellström, Sven}}, isbn = {{91-7874-077-0}}, keywords = {{cyclodextrines; protein identification; m-dispenser; push-pull microdialysis; microdialysis sampling; MALDI-TOF MS; Interleukin-8; Flow immuno assays; Interleukin-10; Analytical chemistry; Analytisk kemi}}, language = {{eng}}, publisher = {{Analytical Chemistry, Lund University}}, school = {{Lund University}}, title = {{Sampling and Selective Detection of Peptides and Proteins Emphazing Microdialysis,Bio-recognition Assays and MALDI-TOF MS}}, year = {{2000}}, }