Monte Carlo simulation of the photon-tagger focal-plane electronics at the MAX IV laboratory
(2013) In Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment 729. p.707-717- Abstract
- Rate-dependent effects in the electronics used to instrument the tagger focal plane at the MAX IV Laboratory have been investigated using the novel approach of Monte Carlo simulation. Results are compared to analytical calculations as well as experimental data for both specialized testing and production running to demonstrate a thorough understanding of the behavior of the detector system.(C) 2013 Elsevier By. All rights reserved.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/4157921
- author
- Myers, L. S. ; Feldman, G. ; Fissum, Kevin LU ; Isaksson, Lennart LU ; Kovash, M. A. ; Nathan, A. M. ; Pywell, R. E. and Schröder, Bent LU
- organization
- publishing date
- 2013
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- Tagger hodoscope, Electronics simulation, Rate dependencies
- in
- Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment
- volume
- 729
- pages
- 707 - 717
- publisher
- Elsevier
- external identifiers
-
- wos:000325753500088
- scopus:84883891468
- ISSN
- 0167-5087
- DOI
- 10.1016/j.nima.2013.08.032
- project
- Elastic and Virtual Compton Scattering and Nucleon Polarizabilities
- Development of Radiation Detectors and Radiation-Detection Techniques
- language
- English
- LU publication?
- yes
- id
- 2108b03b-6c00-4ed0-9a1e-8c839b419c90 (old id 4157921)
- date added to LUP
- 2016-04-01 14:25:57
- date last changed
- 2022-02-27 02:39:22
@article{2108b03b-6c00-4ed0-9a1e-8c839b419c90, abstract = {{Rate-dependent effects in the electronics used to instrument the tagger focal plane at the MAX IV Laboratory have been investigated using the novel approach of Monte Carlo simulation. Results are compared to analytical calculations as well as experimental data for both specialized testing and production running to demonstrate a thorough understanding of the behavior of the detector system.(C) 2013 Elsevier By. All rights reserved.}}, author = {{Myers, L. S. and Feldman, G. and Fissum, Kevin and Isaksson, Lennart and Kovash, M. A. and Nathan, A. M. and Pywell, R. E. and Schröder, Bent}}, issn = {{0167-5087}}, keywords = {{Tagger hodoscope; Electronics simulation; Rate dependencies}}, language = {{eng}}, pages = {{707--717}}, publisher = {{Elsevier}}, series = {{Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment}}, title = {{Monte Carlo simulation of the photon-tagger focal-plane electronics at the MAX IV laboratory}}, url = {{http://dx.doi.org/10.1016/j.nima.2013.08.032}}, doi = {{10.1016/j.nima.2013.08.032}}, volume = {{729}}, year = {{2013}}, }