Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Echo-planar MR imaging of dissolved hyperpolarized 129Xe : Potential for MR angiography

Månsson, S LU orcid ; Johansson, E ; Svensson, Jonas LU ; Olsson, L E LU orcid ; Ståhlberg, F LU ; Petersson, J S LU and Golman, K LU (2002) In Acta Radiologica 43(5). p.60-455
Abstract

PURPOSE: The feasibility of hyperpolarized 129Xe for fast MR angiography (MRA) was evaluated using the echo-planar imaging (EPI) technique.

MATERIAL AND METHODS: Hyperpolarized Xe gas was dissolved in ethanol, a carrier agent with high solubility for Xe (Ostwald solubility coefficient 2.5) and long relaxation times. The dissolved Xe was injected as a bolus into a flow phantom where the mean flow velocity was 15 cm/s. Ultrafast EPI images with 44 ms scan time were acquired of the flowing bolus and the signal-to-noise ratios (SNR) were measured.

RESULTS: The relaxation times of hyperpolarized Xe in ethanol were measured to T1=160+/-11 s and T2 approximately 20 s. The resulting images of the flowing liquid were of reasonable... (More)

PURPOSE: The feasibility of hyperpolarized 129Xe for fast MR angiography (MRA) was evaluated using the echo-planar imaging (EPI) technique.

MATERIAL AND METHODS: Hyperpolarized Xe gas was dissolved in ethanol, a carrier agent with high solubility for Xe (Ostwald solubility coefficient 2.5) and long relaxation times. The dissolved Xe was injected as a bolus into a flow phantom where the mean flow velocity was 15 cm/s. Ultrafast EPI images with 44 ms scan time were acquired of the flowing bolus and the signal-to-noise ratios (SNR) were measured.

RESULTS: The relaxation times of hyperpolarized Xe in ethanol were measured to T1=160+/-11 s and T2 approximately 20 s. The resulting images of the flowing liquid were of reasonable quality and had an SNR of about 70.

CONCLUSION: Based on the SNR of the obtained Xe EPI images, it was estimated that rapid in vivo MRA with 129Xe may be feasible, provided that an efficient, biologically acceptable carrier for Xe can be found and polarization levels of more than 25% can be achieved in isotopically enriched 129Xe.

(Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Echo-Planar Imaging, Feasibility Studies, Magnetic Resonance Angiography, Xenon Isotopes
in
Acta Radiologica
volume
43
issue
5
pages
6 pages
publisher
SAGE Publications
external identifiers
  • pmid:12423454
  • scopus:0036715975
ISSN
0284-1851
DOI
10.1034/j.1600-0455.2002.430503.x
language
English
LU publication?
yes
id
47705d37-a653-4949-a6b8-2c4826a2f290
date added to LUP
2016-08-16 12:12:39
date last changed
2024-10-04 23:58:53
@article{47705d37-a653-4949-a6b8-2c4826a2f290,
  abstract     = {{<p>PURPOSE: The feasibility of hyperpolarized 129Xe for fast MR angiography (MRA) was evaluated using the echo-planar imaging (EPI) technique.</p><p>MATERIAL AND METHODS: Hyperpolarized Xe gas was dissolved in ethanol, a carrier agent with high solubility for Xe (Ostwald solubility coefficient 2.5) and long relaxation times. The dissolved Xe was injected as a bolus into a flow phantom where the mean flow velocity was 15 cm/s. Ultrafast EPI images with 44 ms scan time were acquired of the flowing bolus and the signal-to-noise ratios (SNR) were measured.</p><p>RESULTS: The relaxation times of hyperpolarized Xe in ethanol were measured to T1=160+/-11 s and T2 approximately 20 s. The resulting images of the flowing liquid were of reasonable quality and had an SNR of about 70.</p><p>CONCLUSION: Based on the SNR of the obtained Xe EPI images, it was estimated that rapid in vivo MRA with 129Xe may be feasible, provided that an efficient, biologically acceptable carrier for Xe can be found and polarization levels of more than 25% can be achieved in isotopically enriched 129Xe.</p>}},
  author       = {{Månsson, S and Johansson, E and Svensson, Jonas and Olsson, L E and Ståhlberg, F and Petersson, J S and Golman, K}},
  issn         = {{0284-1851}},
  keywords     = {{Echo-Planar Imaging; Feasibility Studies; Magnetic Resonance Angiography; Xenon Isotopes}},
  language     = {{eng}},
  number       = {{5}},
  pages        = {{60--455}},
  publisher    = {{SAGE Publications}},
  series       = {{Acta Radiologica}},
  title        = {{Echo-planar MR imaging of dissolved hyperpolarized 129Xe : Potential for MR angiography}},
  url          = {{http://dx.doi.org/10.1034/j.1600-0455.2002.430503.x}},
  doi          = {{10.1034/j.1600-0455.2002.430503.x}},
  volume       = {{43}},
  year         = {{2002}},
}