Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Retrospective radiation dosimetry using OSL of electronic components: Results of an inter-laboratory comparison

Bassinet, C. ; Woda, C. ; Bortolin, E. ; Della Monaca, S. ; Fattibene, P. ; Quattrini, M. C. ; Bulanek, B. ; Ekendahl, D. ; Burbidge, C. I. and Cauwels, V. , et al. (2014) In Radiation Measurements 71. p.475-479
Abstract
In the framework of the EU-FP7 MULTIBIODOSE project, two protocols using OSL of resistors removed from the circuit board of mobile phones were developed with the aim to use the resistors as fortuitous dosimeters in the event of a large scale radiological accident. This paper presents the results of an inter-laboratory comparison carried out under the umbrella of EURADOS. The two aims of this exercise were the validation of the MULTIBIODOSE protocols by a large number of laboratories and the dissemination of the method with the objective of preparing the basis for a network that could increase Europe's response capacity in the case of a mass casualty radiological emergency. Twelve institutes from eleven European countries and one institute... (More)
In the framework of the EU-FP7 MULTIBIODOSE project, two protocols using OSL of resistors removed from the circuit board of mobile phones were developed with the aim to use the resistors as fortuitous dosimeters in the event of a large scale radiological accident. This paper presents the results of an inter-laboratory comparison carried out under the umbrella of EURADOS. The two aims of this exercise were the validation of the MULTIBIODOSE protocols by a large number of laboratories and the dissemination of the method with the objective of preparing the basis for a network that could increase Europe's response capacity in the case of a mass casualty radiological emergency. Twelve institutes from eleven European countries and one institute from the USA, with various degrees of expertise in OSL dosimetry, took part in the OSL inter-laboratory comparison. Generally, a good agreement within uncertainties was observed between estimated and nominal doses. (C) 2014 Elsevier Ltd. All rights reserved. (Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; ; ; and , et al. (More)
; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; and (Less)
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Retrospective dosimetry, Radiological accident, Emergency dosimeter, OSL, Resistor, Mobile phones
in
Radiation Measurements
volume
71
pages
475 - 479
publisher
Elsevier
external identifiers
  • wos:000347494400102
  • scopus:84921460124
ISSN
1879-0925
DOI
10.1016/j.radmeas.2014.03.016
language
English
LU publication?
yes
id
7b381bdc-9cc5-451b-bfc3-32cedd80ab62 (old id 5084859)
date added to LUP
2016-04-01 10:59:28
date last changed
2022-05-13 22:07:39
@article{7b381bdc-9cc5-451b-bfc3-32cedd80ab62,
  abstract     = {{In the framework of the EU-FP7 MULTIBIODOSE project, two protocols using OSL of resistors removed from the circuit board of mobile phones were developed with the aim to use the resistors as fortuitous dosimeters in the event of a large scale radiological accident. This paper presents the results of an inter-laboratory comparison carried out under the umbrella of EURADOS. The two aims of this exercise were the validation of the MULTIBIODOSE protocols by a large number of laboratories and the dissemination of the method with the objective of preparing the basis for a network that could increase Europe's response capacity in the case of a mass casualty radiological emergency. Twelve institutes from eleven European countries and one institute from the USA, with various degrees of expertise in OSL dosimetry, took part in the OSL inter-laboratory comparison. Generally, a good agreement within uncertainties was observed between estimated and nominal doses. (C) 2014 Elsevier Ltd. All rights reserved.}},
  author       = {{Bassinet, C. and Woda, C. and Bortolin, E. and Della Monaca, S. and Fattibene, P. and Quattrini, M. C. and Bulanek, B. and Ekendahl, D. and Burbidge, C. I. and Cauwels, V. and Kouroukla, E. and Geber, Therese and Mrozik, A. and Marczewska, B. and Bilski, P. and Sholom, S. and McKeever, S. W. S. and Smith, R. W. and Veronese, I. and Galli, A. and Panzeri, L. and Martini, M.}},
  issn         = {{1879-0925}},
  keywords     = {{Retrospective dosimetry; Radiological accident; Emergency dosimeter; OSL; Resistor; Mobile phones}},
  language     = {{eng}},
  pages        = {{475--479}},
  publisher    = {{Elsevier}},
  series       = {{Radiation Measurements}},
  title        = {{Retrospective radiation dosimetry using OSL of electronic components: Results of an inter-laboratory comparison}},
  url          = {{http://dx.doi.org/10.1016/j.radmeas.2014.03.016}},
  doi          = {{10.1016/j.radmeas.2014.03.016}},
  volume       = {{71}},
  year         = {{2014}},
}