Comparison of measured and calculated temperature and relative humidity with varied and constant air flow in the facade air gap
(2011) 9th Nordic Symposium on Building Physics 1. p.147-154- Abstract
- Calculation of relative humidity and temperature in an early stage of the design process is important to avoid moisture damages in wooden walls. Previous studies show that a sufficient air flow in the air gap behind the façade panel is important to ensure a moisture safe construction. This study investigates if blind WUFI 5.0 calculations with a varied air flow in the air gap behind the façade give a better correlation to measured values compared to calculations with a constant air flow. Calculations for two cases are compared to measured values in single family house. The results show that calculations with a wind dependent air flow does not necessary give better correlation to measured values compared to calculations with a constant air... (More)
- Calculation of relative humidity and temperature in an early stage of the design process is important to avoid moisture damages in wooden walls. Previous studies show that a sufficient air flow in the air gap behind the façade panel is important to ensure a moisture safe construction. This study investigates if blind WUFI 5.0 calculations with a varied air flow in the air gap behind the façade give a better correlation to measured values compared to calculations with a constant air flow. Calculations for two cases are compared to measured values in single family house. The results show that calculations with a wind dependent air flow does not necessary give better correlation to measured values compared to calculations with a constant air flow. However, the calculated values are confirmed with measured values during the warm period and there are deviations in the outer part of the wall during the cold period. Variations in measured values at the same depth in different places in the studied wall are larger compared to differences between calculated values with or without a wind dependent air flow in the façade air gap. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/5218467
- author
- Mundt Petersen, Solof LU and Harderup, Lars-Erik LU
- organization
- publishing date
- 2011
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- keywords
- Comparison, measurements, moisture, WUFI 5.0, calculations mould
- host publication
- Proceedings of the 9th Nordic Symposium on Building Physics - NSB 2011
- editor
- Vinha, Juha ; Piironen, Jarkko and Salminen, Kati
- volume
- 1
- pages
- 8 pages
- publisher
- Tampere University of Technology
- conference name
- 9th Nordic Symposium on Building Physics
- conference location
- Tampere, Finland
- conference dates
- 2011-05-29 - 2011-06-01
- ISBN
- 978-952-15-2574-2
- language
- English
- LU publication?
- yes
- id
- 66f9dfb9-ed25-4cc6-acb2-778ca2cd9384 (old id 5218467)
- date added to LUP
- 2016-04-04 10:17:48
- date last changed
- 2018-11-21 20:57:59
@inproceedings{66f9dfb9-ed25-4cc6-acb2-778ca2cd9384, abstract = {{Calculation of relative humidity and temperature in an early stage of the design process is important to avoid moisture damages in wooden walls. Previous studies show that a sufficient air flow in the air gap behind the façade panel is important to ensure a moisture safe construction. This study investigates if blind WUFI 5.0 calculations with a varied air flow in the air gap behind the façade give a better correlation to measured values compared to calculations with a constant air flow. Calculations for two cases are compared to measured values in single family house. The results show that calculations with a wind dependent air flow does not necessary give better correlation to measured values compared to calculations with a constant air flow. However, the calculated values are confirmed with measured values during the warm period and there are deviations in the outer part of the wall during the cold period. Variations in measured values at the same depth in different places in the studied wall are larger compared to differences between calculated values with or without a wind dependent air flow in the façade air gap.}}, author = {{Mundt Petersen, Solof and Harderup, Lars-Erik}}, booktitle = {{Proceedings of the 9th Nordic Symposium on Building Physics - NSB 2011}}, editor = {{Vinha, Juha and Piironen, Jarkko and Salminen, Kati}}, isbn = {{978-952-15-2574-2}}, keywords = {{Comparison; measurements; moisture; WUFI 5.0; calculations mould}}, language = {{eng}}, pages = {{147--154}}, publisher = {{Tampere University of Technology}}, title = {{Comparison of measured and calculated temperature and relative humidity with varied and constant air flow in the facade air gap}}, url = {{https://lup.lub.lu.se/search/files/5507623/5218492.pdf}}, volume = {{1}}, year = {{2011}}, }