Assessing Measurements for Feed-Forward Control
(2001) European Control Conference, 2001- Abstract
- A method is presented for assessing disturbances in SISO loops.The method indicates if the SISO loop under consideration will benefit from an addition of feed forward control from a measured disturbance. The method uses minimal process knowledge and is based on measurement from normal operation.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/537861
- author
- Petersson, Mikael LU ; Årzén, Karl-Erik LU and Hägglund, Tore LU
- organization
- publishing date
- 2001
- type
- Contribution to conference
- publication status
- published
- subject
- keywords
- Feedforward Control, Control Structure Selection, Supervision, Process Control, PID Control
- conference name
- European Control Conference, 2001
- conference location
- Porto, Portugal
- conference dates
- 2001-09-04 - 2001-09-07
- language
- English
- LU publication?
- yes
- id
- fee3b93e-d40f-46df-a77b-78e5c7e2b4d4 (old id 537861)
- date added to LUP
- 2016-04-04 13:06:34
- date last changed
- 2020-12-12 02:19:05
@misc{fee3b93e-d40f-46df-a77b-78e5c7e2b4d4, abstract = {{A method is presented for assessing disturbances in SISO loops.The method indicates if the SISO loop under consideration will benefit from an addition of feed forward control from a measured disturbance. The method uses minimal process knowledge and is based on measurement from normal operation.}}, author = {{Petersson, Mikael and Årzén, Karl-Erik and Hägglund, Tore}}, keywords = {{Feedforward Control; Control Structure Selection; Supervision; Process Control; PID Control}}, language = {{eng}}, title = {{Assessing Measurements for Feed-Forward Control}}, url = {{https://lup.lub.lu.se/search/files/6053843/625714.pdf}}, year = {{2001}}, }