Nanoparticles as pseudo stationary phase in CEC/ESI-MS
(2002) Proceedings - 50th ASMS Conference on Mass Spectrometry and Allied Topics p.905-906- Abstract
- A technique which uses polymer nanoparticles as interaction phase in capillary electrochromatography (CEC)-ESI-MS was described. A continuous full filling technique in which nanoparticles were suspended in the entire electrolyte volume as well as conventional partial filling technique were presented. The results verified that polymer nanoparticles suspended in electrolyte can be used as pseudo stationary phase in CEC with ESI-MS detection using continuous full filling and partial filling techniques. The sample molecules were separated from the nanoparticles in the orthogonal ESI-interface and MS-detection was performed despite the continuous flow of nanoparticles into the interface.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/611458
- author
- Viberg, Peter LU ; Jornten-Karlsson, Magnus ; Petersson, Patrik ; Spégel, Peter LU and Nilsson, Staffan LU
- organization
- publishing date
- 2002
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- keywords
- Partial filling, Stationary phases, Capillary electrochromatography (CEC), Ground potential
- host publication
- Proceedings 50th ASMS Conference on Mass Spectrmetry and Allied Topics
- pages
- 905 - 906
- publisher
- American Society for Mass Spectrometry, Santa Fe, NM, 87505, United States
- conference name
- Proceedings - 50th ASMS Conference on Mass Spectrometry and Allied Topics
- conference location
- Orlando, FL, United States
- conference dates
- 2002-06-02 - 2002-06-06
- external identifiers
-
- scopus:2442658219
- language
- English
- LU publication?
- yes
- additional info
- The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Analytical Chemistry (S/LTH) (011001004)
- id
- 6f85f389-3fa7-4ffe-827b-6db6a9c3c737 (old id 611458)
- date added to LUP
- 2016-04-04 10:59:01
- date last changed
- 2022-02-13 20:38:52
@inproceedings{6f85f389-3fa7-4ffe-827b-6db6a9c3c737, abstract = {{A technique which uses polymer nanoparticles as interaction phase in capillary electrochromatography (CEC)-ESI-MS was described. A continuous full filling technique in which nanoparticles were suspended in the entire electrolyte volume as well as conventional partial filling technique were presented. The results verified that polymer nanoparticles suspended in electrolyte can be used as pseudo stationary phase in CEC with ESI-MS detection using continuous full filling and partial filling techniques. The sample molecules were separated from the nanoparticles in the orthogonal ESI-interface and MS-detection was performed despite the continuous flow of nanoparticles into the interface.}}, author = {{Viberg, Peter and Jornten-Karlsson, Magnus and Petersson, Patrik and Spégel, Peter and Nilsson, Staffan}}, booktitle = {{Proceedings 50th ASMS Conference on Mass Spectrmetry and Allied Topics}}, keywords = {{Partial filling; Stationary phases; Capillary electrochromatography (CEC); Ground potential}}, language = {{eng}}, pages = {{905--906}}, publisher = {{American Society for Mass Spectrometry, Santa Fe, NM, 87505, United States}}, title = {{Nanoparticles as pseudo stationary phase in CEC/ESI-MS}}, year = {{2002}}, }