Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Microbial fuel cell-based biosensor for fast analysis of biodegradable organic matter

Kumlanghan, Ampai LU ; Liu, Jing LU ; Thavarungkul, Panote ; Kanatharana, Proespichaya and Mattiasson, Bo LU (2007) In Biosensors & Bioelectronics 22(12). p.2939-2944
Abstract
The current study was made to develop a biosensor based on a single-chamber microbial fuel cell in which anaerobes were retained in the anode compartment separated from the cathode compartment by a proton exchange membrane. In the sensor a replaceable anaerobic consortium was used for analyzing biodegradable organic matter. The anaerobes acted as biocatalysts in oxidizing organic matter and transferring electrons to the anode. The biocatalysts were renewed for each sample analysis by replacing the old anaerobic consortium with an equal amount of fresh one. A glucose standard solution was used as the target substrate. To obtain the maximum sensor output, the MFC-based sensor system was optimized using an 800 0 resistor as the load to the... (More)
The current study was made to develop a biosensor based on a single-chamber microbial fuel cell in which anaerobes were retained in the anode compartment separated from the cathode compartment by a proton exchange membrane. In the sensor a replaceable anaerobic consortium was used for analyzing biodegradable organic matter. The anaerobes acted as biocatalysts in oxidizing organic matter and transferring electrons to the anode. The biocatalysts were renewed for each sample analysis by replacing the old anaerobic consortium with an equal amount of fresh one. A glucose standard solution was used as the target substrate. To obtain the maximum sensor output, the MFC-based sensor system was optimized using an 800 0 resistor as the load to the external electric circuit and 25 mM phosphate buffer with 50 mM NaCl as catholyte in the aerobic compartment. The temperature of anaerobic compartment was maintained at optimal 37 degrees C. The cell potential across the electrodes increased with increasing loading of glucose. The sensor response was linear against concentration of glucose up to 25 gl(-1). The detection limit was found as 0.025 gl(-1). The microbial fuel cell with replaceable anaerobic consortium could be used as a biosensor for on-line monitoring of organic matter. (c) 2006 Elsevier B.V. All rights reserved. (Less)
Please use this url to cite or link to this publication:
author
; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
biosensor, biochemical oxygen demand, microbial fuel cell
in
Biosensors & Bioelectronics
volume
22
issue
12
pages
2939 - 2944
publisher
Elsevier
external identifiers
  • wos:000247555300025
  • scopus:34248546192
ISSN
1873-4235
DOI
10.1016/j.bios.2006.12.014
language
English
LU publication?
yes
id
6422dca5-107d-4cb3-b526-2716628fc626 (old id 647859)
date added to LUP
2016-04-01 16:36:30
date last changed
2022-04-22 23:12:42
@article{6422dca5-107d-4cb3-b526-2716628fc626,
  abstract     = {{The current study was made to develop a biosensor based on a single-chamber microbial fuel cell in which anaerobes were retained in the anode compartment separated from the cathode compartment by a proton exchange membrane. In the sensor a replaceable anaerobic consortium was used for analyzing biodegradable organic matter. The anaerobes acted as biocatalysts in oxidizing organic matter and transferring electrons to the anode. The biocatalysts were renewed for each sample analysis by replacing the old anaerobic consortium with an equal amount of fresh one. A glucose standard solution was used as the target substrate. To obtain the maximum sensor output, the MFC-based sensor system was optimized using an 800 0 resistor as the load to the external electric circuit and 25 mM phosphate buffer with 50 mM NaCl as catholyte in the aerobic compartment. The temperature of anaerobic compartment was maintained at optimal 37 degrees C. The cell potential across the electrodes increased with increasing loading of glucose. The sensor response was linear against concentration of glucose up to 25 gl(-1). The detection limit was found as 0.025 gl(-1). The microbial fuel cell with replaceable anaerobic consortium could be used as a biosensor for on-line monitoring of organic matter. (c) 2006 Elsevier B.V. All rights reserved.}},
  author       = {{Kumlanghan, Ampai and Liu, Jing and Thavarungkul, Panote and Kanatharana, Proespichaya and Mattiasson, Bo}},
  issn         = {{1873-4235}},
  keywords     = {{biosensor; biochemical oxygen demand; microbial fuel cell}},
  language     = {{eng}},
  number       = {{12}},
  pages        = {{2939--2944}},
  publisher    = {{Elsevier}},
  series       = {{Biosensors & Bioelectronics}},
  title        = {{Microbial fuel cell-based biosensor for fast analysis of biodegradable organic matter}},
  url          = {{http://dx.doi.org/10.1016/j.bios.2006.12.014}},
  doi          = {{10.1016/j.bios.2006.12.014}},
  volume       = {{22}},
  year         = {{2007}},
}