Two-photon fluorescence lifetime imaging applied to the mixing of two non-isothermal sprays : temperature and mixing fraction measurements

Wang, Minghao ; Stiti, Mehdi LU ; Chaynes, Hadrien ; Becker, Simon ; Berrocal, Edouard LU ; Lemoine, Fabrice and Castanet, Guillaume (2022) In Experiments in Fluids 63(11).
Abstract

Droplets temperature is a key parameter for the study of heat and mass transfers in many spray applications. Time correlated single photons counting (TCSPC) is applied to monitor the fluorescence decay and determine the droplet temperature in the mixing zone of two sprays which are injected with significantly different temperatures. For some well-chosen fluorescent dye, like rhodamine B (RhB), the fluorescence lifetime strongly varies with the temperature. Provided sufficiently different fluorescence lifetimes for the droplets of the two sprays, the fluorescence decay is expected to follow a multiple exponential decay. In this study, different approaches are tested for measuring the temperature of the two sprays as well as their mixing... (More)

Droplets temperature is a key parameter for the study of heat and mass transfers in many spray applications. Time correlated single photons counting (TCSPC) is applied to monitor the fluorescence decay and determine the droplet temperature in the mixing zone of two sprays which are injected with significantly different temperatures. For some well-chosen fluorescent dye, like rhodamine B (RhB), the fluorescence lifetime strongly varies with the temperature. Provided sufficiently different fluorescence lifetimes for the droplets of the two sprays, the fluorescence decay is expected to follow a multiple exponential decay. In this study, different approaches are tested for measuring the temperature of the two sprays as well as their mixing fraction based on the analysis of the fluorescence decay. Firstly, the measurement of the mixture fraction alone is tested by considering a configuration where one spray is seeded with eosin Y (EY) and the other with rhodamine 6G (Rh6G). Given the very different lifetimes of these dyes, which are not temperature dependent, the fluorescence decay is function of the volume fraction of liquid from each spray in these tests. A calibration is necessary to evaluate the mixing fraction. Both sprays are mounted on an automated platform allowing 3D scanning and motions which allows obtaining maps of the fluorescence decay. The out-of-field fluorescence, observed in dense sprays when fluorescence is induced by one-photon absorption, is suppressed by using a two-photon fluorescence excitation. This approach significantly improves the spatial resolution of the measurements. Finally, both the droplet temperature and the mixing fraction are measured simultaneously using a single dye, namely RhB, whose fluorescence lifetime is temperature dependent. Special care must be paid to the fact that RhB does not have a purely monoexponential decay at a given temperature. The fluorescence decay in the mixing zone of the two sprays is considered as a combination of two biexponentials. Results show that the volume fraction of a spray must exceed about 10% to make it possible to determine its temperature with an accuracy of about 2–3 °C. Simultaneous measurements of the sprays temperatures and volume fractions provide a means to calculate the mixing temperature (the average between the temperatures of the two sprays weighted by their volume fractions). Graphical abstract: [Figure not available: see fulltext.].

(Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Experiments in Fluids
volume
63
issue
11
article number
172
publisher
Springer
external identifiers
  • scopus:85141042979
ISSN
0723-4864
DOI
10.1007/s00348-022-03515-5
language
English
LU publication?
yes
id
6ed8e1fe-f4c0-412b-9ae0-ef258d4ba6ba
date added to LUP
2022-12-02 13:27:05
date last changed
2023-11-06 16:56:54
@article{6ed8e1fe-f4c0-412b-9ae0-ef258d4ba6ba,
  abstract     = {{<p>Droplets temperature is a key parameter for the study of heat and mass transfers in many spray applications. Time correlated single photons counting (TCSPC) is applied to monitor the fluorescence decay and determine the droplet temperature in the mixing zone of two sprays which are injected with significantly different temperatures. For some well-chosen fluorescent dye, like rhodamine B (RhB), the fluorescence lifetime strongly varies with the temperature. Provided sufficiently different fluorescence lifetimes for the droplets of the two sprays, the fluorescence decay is expected to follow a multiple exponential decay. In this study, different approaches are tested for measuring the temperature of the two sprays as well as their mixing fraction based on the analysis of the fluorescence decay. Firstly, the measurement of the mixture fraction alone is tested by considering a configuration where one spray is seeded with eosin Y (EY) and the other with rhodamine 6G (Rh6G). Given the very different lifetimes of these dyes, which are not temperature dependent, the fluorescence decay is function of the volume fraction of liquid from each spray in these tests. A calibration is necessary to evaluate the mixing fraction. Both sprays are mounted on an automated platform allowing 3D scanning and motions which allows obtaining maps of the fluorescence decay. The out-of-field fluorescence, observed in dense sprays when fluorescence is induced by one-photon absorption, is suppressed by using a two-photon fluorescence excitation. This approach significantly improves the spatial resolution of the measurements. Finally, both the droplet temperature and the mixing fraction are measured simultaneously using a single dye, namely RhB, whose fluorescence lifetime is temperature dependent. Special care must be paid to the fact that RhB does not have a purely monoexponential decay at a given temperature. The fluorescence decay in the mixing zone of the two sprays is considered as a combination of two biexponentials. Results show that the volume fraction of a spray must exceed about 10% to make it possible to determine its temperature with an accuracy of about 2–3 °C. Simultaneous measurements of the sprays temperatures and volume fractions provide a means to calculate the mixing temperature (the average between the temperatures of the two sprays weighted by their volume fractions). Graphical abstract: [Figure not available: see fulltext.].</p>}},
  author       = {{Wang, Minghao and Stiti, Mehdi and Chaynes, Hadrien and Becker, Simon and Berrocal, Edouard and Lemoine, Fabrice and Castanet, Guillaume}},
  issn         = {{0723-4864}},
  language     = {{eng}},
  number       = {{11}},
  publisher    = {{Springer}},
  series       = {{Experiments in Fluids}},
  title        = {{Two-photon fluorescence lifetime imaging applied to the mixing of two non-isothermal sprays : temperature and mixing fraction measurements}},
  url          = {{http://dx.doi.org/10.1007/s00348-022-03515-5}},
  doi          = {{10.1007/s00348-022-03515-5}},
  volume       = {{63}},
  year         = {{2022}},
}