In vivo high field myelin water imaging: Investigating the T2 distribution at 7T
(2018) In Proc Intl Soc Magn Reson Med 26.- Abstract
 - With the increased frequency of human 7T scanners, there is also a drive towards the implementation advanced MR sequences, such a myelin water imaging, at high fields. Here, we demonstrate the feasibility of translating 3T myelin acquisitions scheme, GRASE, to 7T. We studied the distribution of T values at 7T and determined that myelin water has a T <25ms. We obtained excellent agreement for myelin water fraction values in the corpus callosum between 3T and 7T.
 
    Please use this url to cite or link to this publication:
    https://lup.lub.lu.se/record/76516f9a-e94b-4f70-8c51-bd6ce422d735
- author
 - 						Wiggermann, Vanessa
	; 						MacKay, Alex L
	; 						Helms, Gunther
				LU
				
	 and 						Rauscher, Alexander
	 - organization
 - publishing date
 - 2018-06-01
 - type
 - Chapter in Book/Report/Conference proceeding
 - publication status
 - published
 - subject
 - host publication
 - In vivo high field myelin water imaging: Investigating the T2 distribution at 7T
 - series title
 - Proc Intl Soc Magn Reson Med
 - volume
 - 26
 - article number
 - 5499
 - pages
 - 3 pages
 - publisher
 - International Society for Magnetic Resonance in Medicine
 - ISSN
 - 1545-4428
 - project
 - T2 mapping and myelin water imaging at 7T using 3D GraSe
 - language
 - English
 - LU publication?
 - yes
 - id
 - 76516f9a-e94b-4f70-8c51-bd6ce422d735
 - alternative location
 - http://indexsmart.mirasmart.com/ISMRM2018/PDFfiles/5499.html
 - date added to LUP
 - 2018-08-10 21:02:54
 - date last changed
 - 2025-04-04 14:16:54
 
@inproceedings{76516f9a-e94b-4f70-8c51-bd6ce422d735,
  abstract     = {{With the increased frequency of human 7T scanners, there is also a drive towards the implementation advanced MR sequences, such a myelin water imaging, at high fields. Here, we demonstrate the feasibility of translating 3T myelin acquisitions scheme, GRASE, to 7T. We studied the distribution of T values at 7T and determined that myelin water has a T <25ms. We obtained excellent agreement for myelin water fraction values in the corpus callosum between 3T and 7T.}},
  author       = {{Wiggermann, Vanessa and MacKay, Alex L and Helms, Gunther and Rauscher, Alexander}},
  booktitle    = {{In vivo high field myelin water imaging: Investigating the T2 distribution at 7T}},
  issn         = {{1545-4428}},
  language     = {{eng}},
  month        = {{06}},
  publisher    = {{International Society for Magnetic Resonance in Medicine}},
  series       = {{Proc Intl Soc Magn Reson Med}},
  title        = {{In vivo high field myelin water imaging: Investigating the T2 distribution at 7T}},
  url          = {{https://lup.lub.lu.se/search/files/49254951/Proc.Intl.Soc.Magn.Reson.Med.26_2018_2655.pdf}},
  volume       = {{26}},
  year         = {{2018}},
}