Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Particle Size Calibration between the Aerodynamic Particle Sizer and Optical Microscope for Wind Tunnel Studies with Particles of Fused Alumina

Gudmundsson, Anders LU ; Petersen, OH ; Schneider, T and Bohgard, Mats LU (1991) In Journal of Aerosol Science 22 S1. p.347-350
Abstract
Abstract

When studying the deposition of particles in wind tunnel experiments, we measure theairborne particles with an Aerodynamic Particle Sizer (APS). The deposited particles are examined with an optical microscope connected to an image analyzer. Calibration between the APS and the optical microscope determinations of particle size has been performed for particles of fused alumina. The particle size calibration procedure is performed by comparing the 50% cutoff sizes, determined with APS and optical microscopy measurements, for different single-stage impactors.
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
aerodynamic particle sizer, particle size calibration, particles of fused alumina, optical microscope
in
Journal of Aerosol Science
volume
22 S1
pages
347 - 350
publisher
Elsevier
external identifiers
  • scopus:0026403106
ISSN
0021-8502
DOI
10.1016/S0021-8502(05)80109-0
language
English
LU publication?
yes
id
c1888431-cfb8-4765-9ce4-55da2d6dd75b (old id 798791)
alternative location
http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6V6B-4FXXR3S-38&_user=745831&_coverDate=12%2F31%2F1991&_alid=688981166&_rdoc=1&_fmt=summary&_orig=search&_cdi=5810&_sort=d&_docanchor=&view=c&_ct=1&_acct=C000041498&_version=1&_urlVersion=0&_userid=745831&md5=a6be2254847390c65014f57a97c244a1
date added to LUP
2016-04-04 09:20:52
date last changed
2021-01-03 10:27:14
@article{c1888431-cfb8-4765-9ce4-55da2d6dd75b,
  abstract     = {{Abstract<br/><br>
When studying the deposition of particles in wind tunnel experiments, we measure theairborne particles with an Aerodynamic Particle Sizer (APS). The deposited particles are examined with an optical microscope connected to an image analyzer. Calibration between the APS and the optical microscope determinations of particle size has been performed for particles of fused alumina. The particle size calibration procedure is performed by comparing the 50% cutoff sizes, determined with APS and optical microscopy measurements, for different single-stage impactors.}},
  author       = {{Gudmundsson, Anders and Petersen, OH and Schneider, T and Bohgard, Mats}},
  issn         = {{0021-8502}},
  keywords     = {{aerodynamic particle sizer; particle size calibration; particles of fused alumina; optical microscope}},
  language     = {{eng}},
  pages        = {{347--350}},
  publisher    = {{Elsevier}},
  series       = {{Journal of Aerosol Science}},
  title        = {{Particle Size Calibration between the Aerodynamic Particle Sizer and Optical Microscope for Wind Tunnel Studies with Particles of Fused Alumina}},
  url          = {{http://dx.doi.org/10.1016/S0021-8502(05)80109-0}},
  doi          = {{10.1016/S0021-8502(05)80109-0}},
  volume       = {{22 S1}},
  year         = {{1991}},
}