Applications of SU-8 in the development of a Single Ion Hit Facility
(2009) 11th International Conference on Nuclear Microprobe Technology and Applications/3rd International Workshop on Proton Beam Writing 267(12-13). p.2117-2121- Abstract
- The Lund Nuclear Microprobe (LNM) has been adapted to be used as a Single Ion Hit Facility (SIHF) for proton cell irradiation experiments at low dose. In order to test the capabilities of the system, Ni dot arrays and artificial cells have been fabricated with the photopolymer SU-8 and common lithographic techniques. The primary purpose of the Ni dot arrays was to determine the targeting accuracy of the beam in vacuum and in air. Additionally, this sample was employed to evaluate the system performance during cell target irradiation experiments. The Ni dot arrays were also used for beam characterization. The artificial cells were originally fabricated to test the software for cell recognition and localization, developed and implemented at... (More)
- The Lund Nuclear Microprobe (LNM) has been adapted to be used as a Single Ion Hit Facility (SIHF) for proton cell irradiation experiments at low dose. In order to test the capabilities of the system, Ni dot arrays and artificial cells have been fabricated with the photopolymer SU-8 and common lithographic techniques. The primary purpose of the Ni dot arrays was to determine the targeting accuracy of the beam in vacuum and in air. Additionally, this sample was employed to evaluate the system performance during cell target irradiation experiments. The Ni dot arrays were also used for beam characterization. The artificial cells were originally fabricated to test the software for cell recognition and localization, developed and implemented at the LNM. However, this sample became very functional to make small adjustments at the irradiation chamber for cell irradiation experiments. A description of the samples, fabrication procedure and applications are presented in this paper. (C) 2009 Elsevier B.V. All rights reserved. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1462419
- author
- Arteaga, Natalia LU ; Astromskas, Gvidas LU ; Gram, Magnus LU ; Elfman, Mikael LU ; Kristiansson, Per LU ; Fors, Erik LU ; Nilsson, Charlotta LU and Pallon, Jan LU
- organization
- publishing date
- 2009
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- keywords
- Cell irradiation, SU-8, EBL, Single Ion Hit Facility (SIHF), PMMA
- host publication
- Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- volume
- 267
- issue
- 12-13
- pages
- 2117 - 2121
- publisher
- Elsevier
- conference name
- 11th International Conference on Nuclear Microprobe Technology and Applications/3rd International Workshop on Proton Beam Writing
- conference location
- Debrecen, Hungary
- conference dates
- 2008-07-20 - 2008-07-25
- external identifiers
-
- wos:000267910500029
- scopus:66349114284
- ISSN
- 0168-583X
- DOI
- 10.1016/j.nimb.2009.03.009
- language
- English
- LU publication?
- yes
- additional info
- The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Division of Infection Medicine (BMC) (013024020), Solid State Physics (011013006), Nuclear Physics (Faculty of Technology) (011013007)
- id
- 79dce31e-248e-437f-834e-48d2c57567cb (old id 1462419)
- date added to LUP
- 2016-04-01 14:01:32
- date last changed
- 2022-01-27 22:27:58
@inproceedings{79dce31e-248e-437f-834e-48d2c57567cb, abstract = {{The Lund Nuclear Microprobe (LNM) has been adapted to be used as a Single Ion Hit Facility (SIHF) for proton cell irradiation experiments at low dose. In order to test the capabilities of the system, Ni dot arrays and artificial cells have been fabricated with the photopolymer SU-8 and common lithographic techniques. The primary purpose of the Ni dot arrays was to determine the targeting accuracy of the beam in vacuum and in air. Additionally, this sample was employed to evaluate the system performance during cell target irradiation experiments. The Ni dot arrays were also used for beam characterization. The artificial cells were originally fabricated to test the software for cell recognition and localization, developed and implemented at the LNM. However, this sample became very functional to make small adjustments at the irradiation chamber for cell irradiation experiments. A description of the samples, fabrication procedure and applications are presented in this paper. (C) 2009 Elsevier B.V. All rights reserved.}}, author = {{Arteaga, Natalia and Astromskas, Gvidas and Gram, Magnus and Elfman, Mikael and Kristiansson, Per and Fors, Erik and Nilsson, Charlotta and Pallon, Jan}}, booktitle = {{Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms}}, issn = {{0168-583X}}, keywords = {{Cell irradiation; SU-8; EBL; Single Ion Hit Facility (SIHF); PMMA}}, language = {{eng}}, number = {{12-13}}, pages = {{2117--2121}}, publisher = {{Elsevier}}, title = {{Applications of SU-8 in the development of a Single Ion Hit Facility}}, url = {{http://dx.doi.org/10.1016/j.nimb.2009.03.009}}, doi = {{10.1016/j.nimb.2009.03.009}}, volume = {{267}}, year = {{2009}}, }