Multipoint temperature and oxygen-concentration measurements using rotational coherent anti-Stokes Raman spectroscopy
(2000) In Optics Letters 25(20). p.1535-1537- Abstract
A novel technique for coherent anti-Stokes Raman spectroscopy (CARS) measurements in multiple points is presented. With a system of cylindrical lenses, each laser beam is split into several focused beams, yielding separate planar boxcars configurations. Spectrally resolved CARS signals are detected at different heights on the CCD chip. With dual-broadband rotational CARS the setup is demonstrated for quantitative measurements of temperature- and oxygen-concentration profiles. The technique was demonstrated for three points only, but it can be extended to more points by use of special optics; this choice must be based on a sufficient signal-to-noise ratio in all points for the actual measurement condition.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/8068e517-6560-4c2d-ad52-2d57494cd8bd
- author
- Bood, Joakim LU ; Brackmann, Christian LU ; Bengtsson, Per Erik LU and Aldén, Marcus LU
- organization
- publishing date
- 2000-10-15
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Optics Letters
- volume
- 25
- issue
- 20
- pages
- 3 pages
- publisher
- Optical Society of America
- external identifiers
-
- scopus:0042730609
- ISSN
- 0146-9592
- language
- English
- LU publication?
- yes
- id
- 8068e517-6560-4c2d-ad52-2d57494cd8bd
- date added to LUP
- 2016-06-29 16:49:27
- date last changed
- 2022-04-03 18:44:28
@article{8068e517-6560-4c2d-ad52-2d57494cd8bd, abstract = {{<p>A novel technique for coherent anti-Stokes Raman spectroscopy (CARS) measurements in multiple points is presented. With a system of cylindrical lenses, each laser beam is split into several focused beams, yielding separate planar boxcars configurations. Spectrally resolved CARS signals are detected at different heights on the CCD chip. With dual-broadband rotational CARS the setup is demonstrated for quantitative measurements of temperature- and oxygen-concentration profiles. The technique was demonstrated for three points only, but it can be extended to more points by use of special optics; this choice must be based on a sufficient signal-to-noise ratio in all points for the actual measurement condition.</p>}}, author = {{Bood, Joakim and Brackmann, Christian and Bengtsson, Per Erik and Aldén, Marcus}}, issn = {{0146-9592}}, language = {{eng}}, month = {{10}}, number = {{20}}, pages = {{1535--1537}}, publisher = {{Optical Society of America}}, series = {{Optics Letters}}, title = {{Multipoint temperature and oxygen-concentration measurements using rotational coherent anti-Stokes Raman spectroscopy}}, volume = {{25}}, year = {{2000}}, }