Blood-brain barrier permeability in rats exposed to electromagnetic fields used in wireless communication

Persson, Bertil R LU orcid ; Salford, Leif G. and Brun, Arne LU (1997) In Wireless Networks 3. p.455-461
Abstract
iological effects of radio frequency electromagnetic fields (EMF) on the blood-brain barrier (BBB) have been studied in Fischer 344

rats of both sexes. The rats were not anaesthetised during the exposure. All animals were sacrificed by perfusion–fixation of the brains

under chloralhydrate anaesthesia after the exposure. The brains were perfused with saline for 3–4 minutes, and thereafter perfusion fixed

with 4% formaldehyde for 5–6 minutes. Whole coronal sections of the brains were dehydrated and embedded in paraffin and sectioned

at 5 m. Albumin and fibrinogen were demonstrated immunohistochemically and classified as normal versus pathological leakage. In

the present investigation we exposed... (More)
iological effects of radio frequency electromagnetic fields (EMF) on the blood-brain barrier (BBB) have been studied in Fischer 344

rats of both sexes. The rats were not anaesthetised during the exposure. All animals were sacrificed by perfusion–fixation of the brains

under chloralhydrate anaesthesia after the exposure. The brains were perfused with saline for 3–4 minutes, and thereafter perfusion fixed

with 4% formaldehyde for 5–6 minutes. Whole coronal sections of the brains were dehydrated and embedded in paraffin and sectioned

at 5 m. Albumin and fibrinogen were demonstrated immunohistochemically and classified as normal versus pathological leakage. In

the present investigation we exposed male and female Fischer 344 rats in a Transverse Electromagnetic Transmission line chamber to

microwaves of 915 MHz as continuous wave (CW) and pulse-modulated with different pulse power and at various time intervals. The

CW-pulse power varied from 0.001 W to 10 W and the exposure time from 2 min to 960 min. In each experiment we exposed 4–6

rats with 2–4 controls randomly placed in excited and non-excited TEM-cells respectively. We have in total investigated 630 exposed

rats at various modulation frequencies and 372 controls. The frequency of pathological rats is significantly increased (p < 0:0001) from

62=372 (ratio: 0:170:02) for control rats to 244=630 (ratio: 0:390:03) in all exposed rats. Grouping the exposed animals according

to the level of specific absorbed energy (J/kg) give significant difference in all levels above 1.5 J/kg. The exposure was 915 MHz

microwaves either pulse modulated (PW) at 217 Hz with 0.57 ms pulse width, at 50 Hz with 6.6 ms pulse width or continuous wave

(CW). The frequency of pathological rats (0:17) among controls in the various groups is not significantly different. The frequency of

pathological rats was 170=481 (0:350:03) among rats exposed to pulse modulated (PW) and 74=149 (0:500:07) among rats exposed

to continuous wave exposure (CW). These results are both highly significantly different to their corresponding controls (p < 0:0001)

and the frequency of pathological rats after exposure to pulsed radiation (PW) is significantly less (p < 0:002) than after exposure to

continuous radiation (CW). (Less)
Please use this url to cite or link to this publication:
author
; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Blood-brain barrier, permeability, rats, electromagnetic, fields, wireless, communication
in
Wireless Networks
volume
3
pages
455 - 461
publisher
J.C. Baltzer AG, Science Publishers
external identifiers
  • scopus:0031273912
ISSN
1022-0038
language
English
LU publication?
yes
additional info
The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Department of Clinical Sciences, Lund (013230000), Radiation Physics, Lund (013034000), Pathology, (Lund) (013030000), Neurosurgery (013026000)
id
80cab411-ff01-4c9b-8f56-28213042784b (old id 3634015)
date added to LUP
2016-04-04 11:31:59
date last changed
2022-01-29 21:58:43
@article{80cab411-ff01-4c9b-8f56-28213042784b,
  abstract     = {{iological effects of radio frequency electromagnetic fields (EMF) on the blood-brain barrier (BBB) have been studied in Fischer 344<br/><br>
rats of both sexes. The rats were not anaesthetised during the exposure. All animals were sacrificed by perfusion–fixation of the brains<br/><br>
under chloralhydrate anaesthesia after the exposure. The brains were perfused with saline for 3–4 minutes, and thereafter perfusion fixed<br/><br>
with 4% formaldehyde for 5–6 minutes. Whole coronal sections of the brains were dehydrated and embedded in paraffin and sectioned<br/><br>
at 5 m. Albumin and fibrinogen were demonstrated immunohistochemically and classified as normal versus pathological leakage. In<br/><br>
the present investigation we exposed male and female Fischer 344 rats in a Transverse Electromagnetic Transmission line chamber to<br/><br>
microwaves of 915 MHz as continuous wave (CW) and pulse-modulated with different pulse power and at various time intervals. The<br/><br>
CW-pulse power varied from 0.001 W to 10 W and the exposure time from 2 min to 960 min. In each experiment we exposed 4–6<br/><br>
rats with 2–4 controls randomly placed in excited and non-excited TEM-cells respectively. We have in total investigated 630 exposed<br/><br>
rats at various modulation frequencies and 372 controls. The frequency of pathological rats is significantly increased (p &lt; 0:0001) from<br/><br>
62=372 (ratio: 0:170:02) for control rats to 244=630 (ratio: 0:390:03) in all exposed rats. Grouping the exposed animals according<br/><br>
to the level of specific absorbed energy (J/kg) give significant difference in all levels above 1.5 J/kg. The exposure was 915 MHz<br/><br>
microwaves either pulse modulated (PW) at 217 Hz with 0.57 ms pulse width, at 50 Hz with 6.6 ms pulse width or continuous wave<br/><br>
(CW). The frequency of pathological rats (0:17) among controls in the various groups is not significantly different. The frequency of<br/><br>
pathological rats was 170=481 (0:350:03) among rats exposed to pulse modulated (PW) and 74=149 (0:500:07) among rats exposed<br/><br>
to continuous wave exposure (CW). These results are both highly significantly different to their corresponding controls (p &lt; 0:0001)<br/><br>
and the frequency of pathological rats after exposure to pulsed radiation (PW) is significantly less (p &lt; 0:002) than after exposure to<br/><br>
continuous radiation (CW).}},
  author       = {{Persson, Bertil R and Salford, Leif G. and Brun, Arne}},
  issn         = {{1022-0038}},
  keywords     = {{Blood-brain barrier; permeability; rats; electromagnetic; fields; wireless; communication}},
  language     = {{eng}},
  pages        = {{455--461}},
  publisher    = {{J.C. Baltzer AG, Science Publishers}},
  series       = {{Wireless Networks}},
  title        = {{Blood-brain barrier permeability in rats exposed to electromagnetic fields used in wireless communication}},
  url          = {{https://lup.lub.lu.se/search/files/5795616/3634019.pdf}},
  volume       = {{3}},
  year         = {{1997}},
}