Detection of Right-to-Left Cardiac Shunt in the Absence of Transcranial Acoustic Bone.
(2015) In Journal of Neuroimaging- Abstract
- Paradoxical thrombotic embolism via right-to-left cardiac shunt (RLS) is a risk factor of cryptogenic ischemic stroke. Transtemporal Doppler (TTD) is a valid method used in the detection of patent foramen ovale (PFO). Temporal acoustic bone windows are missing with increasing age and in some younger subjects. We studied prospectively whether Doppler ultrasound of the cervical arteries (submandibular internal carotid artery [ICA] and vertebral artery [VA]) is an alternative, when compared to TTD, in the detection and quantification of PFO.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/8147923
- author
- Perren, Fabienne ; Kremer, Christine LU ; Iwanovski, Patricia ; Savva, Elena and Landis, Theodor
- organization
- publishing date
- 2015-10-30
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Journal of Neuroimaging
- publisher
- Wiley-Blackwell
- external identifiers
-
- pmid:26514230
- scopus:84945917667
- pmid:26514230
- wos:000382869200003
- ISSN
- 1552-6569
- DOI
- 10.1111/jon.12311
- language
- English
- LU publication?
- yes
- id
- 23129792-aa0e-4ab1-8f2d-03f673a92048 (old id 8147923)
- alternative location
- http://www.ncbi.nlm.nih.gov/pubmed/26514230?dopt=Abstract
- date added to LUP
- 2016-04-04 09:32:47
- date last changed
- 2022-02-13 17:53:35
@article{23129792-aa0e-4ab1-8f2d-03f673a92048, abstract = {{Paradoxical thrombotic embolism via right-to-left cardiac shunt (RLS) is a risk factor of cryptogenic ischemic stroke. Transtemporal Doppler (TTD) is a valid method used in the detection of patent foramen ovale (PFO). Temporal acoustic bone windows are missing with increasing age and in some younger subjects. We studied prospectively whether Doppler ultrasound of the cervical arteries (submandibular internal carotid artery [ICA] and vertebral artery [VA]) is an alternative, when compared to TTD, in the detection and quantification of PFO.}}, author = {{Perren, Fabienne and Kremer, Christine and Iwanovski, Patricia and Savva, Elena and Landis, Theodor}}, issn = {{1552-6569}}, language = {{eng}}, month = {{10}}, publisher = {{Wiley-Blackwell}}, series = {{Journal of Neuroimaging}}, title = {{Detection of Right-to-Left Cardiac Shunt in the Absence of Transcranial Acoustic Bone.}}, url = {{http://dx.doi.org/10.1111/jon.12311}}, doi = {{10.1111/jon.12311}}, year = {{2015}}, }