Volume analysis of true and false lumens in acute complicated type B aortic dissections after thoracic endovascular aortic repair with stent grafts alone or with a composite device design.

Sobocinski, Jonathan ; Lombardi, Joseph V ; Dias, Nuno LU orcid ; Berger, Ludovic ; Zhou, Qing ; Jia, Feiyi ; Resch, Tim LU and Haulon, Stéphan (2016) In Journal of Vascular Surgery 63(5). p.1216-1224
Abstract
This study compared the 12-month evolution of the aortic volume in patients who underwent thoracic endovascular aortic repair (TEVAR) with stent grafts alone or a composite device (Zenith TX2 stent graft and Zenith Dissection stent; Cook Medical, Bloomington, Ind) for acute (≤2 weeks from onset) complicated type B aortic dissection.
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Journal of Vascular Surgery
volume
63
issue
5
pages
1216 - 1224
publisher
Mosby-Elsevier
external identifiers
  • pmid:26806523
  • scopus:84956883956
  • wos:000375216000013
  • pmid:26806523
ISSN
1097-6809
DOI
10.1016/j.jvs.2015.11.037
language
English
LU publication?
yes
id
8b5f5387-553a-43b4-bf3e-18c286b6930a (old id 8573854)
alternative location
http://www.ncbi.nlm.nih.gov/pubmed/26806523?dopt=Abstract
date added to LUP
2016-04-04 09:27:21
date last changed
2022-04-23 20:39:51
@article{8b5f5387-553a-43b4-bf3e-18c286b6930a,
  abstract     = {{This study compared the 12-month evolution of the aortic volume in patients who underwent thoracic endovascular aortic repair (TEVAR) with stent grafts alone or a composite device (Zenith TX2 stent graft and Zenith Dissection stent; Cook Medical, Bloomington, Ind) for acute (≤2 weeks from onset) complicated type B aortic dissection.}},
  author       = {{Sobocinski, Jonathan and Lombardi, Joseph V and Dias, Nuno and Berger, Ludovic and Zhou, Qing and Jia, Feiyi and Resch, Tim and Haulon, Stéphan}},
  issn         = {{1097-6809}},
  language     = {{eng}},
  month        = {{01}},
  number       = {{5}},
  pages        = {{1216--1224}},
  publisher    = {{Mosby-Elsevier}},
  series       = {{Journal of Vascular Surgery}},
  title        = {{Volume analysis of true and false lumens in acute complicated type B aortic dissections after thoracic endovascular aortic repair with stent grafts alone or with a composite device design.}},
  url          = {{http://dx.doi.org/10.1016/j.jvs.2015.11.037}},
  doi          = {{10.1016/j.jvs.2015.11.037}},
  volume       = {{63}},
  year         = {{2016}},
}