Clinical, immunological and bacteriological evaluation of adverse reactions to skin-penetrating titanium implants in the head and neck region
(1992) In Contact Dermatitis 27(1). p.1-7- Abstract
- Between 1977 and October 1989, 445 patients have been treated with bone-anchored skin-penetrating titanium implants for anchorage of facial prostheses or bone-conducting hearing aids, at the Ear, Nose and Throat Department at Sahlgren's Hospital in Gothenburg. The majority of patients had no adverse skin reactions, while a few patients were responsible for the majority of the adverse reactions. The aim of our study was to analyse differences between these groups. We started a clinical study on 9 patients with a clinical history of adverse skin reactions around the titanium implants and 9 patients without adverse skin reactions were used as controls. None of the patients had delayed hypersensitivity to titanium. Microbiological analyses... (More)
- Between 1977 and October 1989, 445 patients have been treated with bone-anchored skin-penetrating titanium implants for anchorage of facial prostheses or bone-conducting hearing aids, at the Ear, Nose and Throat Department at Sahlgren's Hospital in Gothenburg. The majority of patients had no adverse skin reactions, while a few patients were responsible for the majority of the adverse reactions. The aim of our study was to analyse differences between these groups. We started a clinical study on 9 patients with a clinical history of adverse skin reactions around the titanium implants and 9 patients without adverse skin reactions were used as controls. None of the patients had delayed hypersensitivity to titanium. Microbiological analyses showed that when there was clinical irritation, Staphylococcus aureus could be isolated. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1106219
- author
- Holgers, K M ; Roupe, G ; Tjellstrom, A and Bjursten, Lars Magnus LU
- organization
- publishing date
- 1992
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- skin-penetrating titanium implants, adverse reactions, bacterial infection, Staphylococcus aureus, antibiotic treatment, flucloxacillin
- in
- Contact Dermatitis
- volume
- 27
- issue
- 1
- pages
- 1 - 7
- publisher
- Wiley-Blackwell
- external identifiers
-
- pmid:1424584
- scopus:0026721297
- ISSN
- 0105-1873
- DOI
- 10.1111/j.1600-0536.1992.tb05189.x
- language
- English
- LU publication?
- yes
- additional info
- The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Bioimplant Research (013242910)
- id
- 952a68a7-f986-4c18-9465-92eb9ca746bc (old id 1106219)
- date added to LUP
- 2016-04-01 12:26:43
- date last changed
- 2021-04-25 06:10:17
@article{952a68a7-f986-4c18-9465-92eb9ca746bc, abstract = {{Between 1977 and October 1989, 445 patients have been treated with bone-anchored skin-penetrating titanium implants for anchorage of facial prostheses or bone-conducting hearing aids, at the Ear, Nose and Throat Department at Sahlgren's Hospital in Gothenburg. The majority of patients had no adverse skin reactions, while a few patients were responsible for the majority of the adverse reactions. The aim of our study was to analyse differences between these groups. We started a clinical study on 9 patients with a clinical history of adverse skin reactions around the titanium implants and 9 patients without adverse skin reactions were used as controls. None of the patients had delayed hypersensitivity to titanium. Microbiological analyses showed that when there was clinical irritation, Staphylococcus aureus could be isolated.}}, author = {{Holgers, K M and Roupe, G and Tjellstrom, A and Bjursten, Lars Magnus}}, issn = {{0105-1873}}, keywords = {{skin-penetrating titanium implants; adverse reactions; bacterial infection; Staphylococcus aureus; antibiotic treatment; flucloxacillin}}, language = {{eng}}, number = {{1}}, pages = {{1--7}}, publisher = {{Wiley-Blackwell}}, series = {{Contact Dermatitis}}, title = {{Clinical, immunological and bacteriological evaluation of adverse reactions to skin-penetrating titanium implants in the head and neck region}}, url = {{http://dx.doi.org/10.1111/j.1600-0536.1992.tb05189.x}}, doi = {{10.1111/j.1600-0536.1992.tb05189.x}}, volume = {{27}}, year = {{1992}}, }