IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms

Andersson, Martin LU ; Johansson, Lennart LU ; Eckerman, Keith and Mattsson, Sören LU (2017) In EJNMMI Research 7.
Abstract

Background: To date, the estimated radiation-absorbed dose to organs and tissues in patients undergoing diagnostic examinations in nuclear medicine is derived via calculations based on models of the human body and the biokinetic behaviour of the radiopharmaceutical. An internal dosimetry computer program, IDAC-Dose2.1, was developed based on the International Commission on Radiological Protection (ICRP)-specific absorbed fractions and computational framework of internal dose assessment given for reference adults in ICRP Publication 133. The program uses the radionuclide decay database of ICRP Publication 107 and considers 83 different source regions irradiating 47 target tissues, defining the effective dose as presented in ICRP... (More)

Background: To date, the estimated radiation-absorbed dose to organs and tissues in patients undergoing diagnostic examinations in nuclear medicine is derived via calculations based on models of the human body and the biokinetic behaviour of the radiopharmaceutical. An internal dosimetry computer program, IDAC-Dose2.1, was developed based on the International Commission on Radiological Protection (ICRP)-specific absorbed fractions and computational framework of internal dose assessment given for reference adults in ICRP Publication 133. The program uses the radionuclide decay database of ICRP Publication 107 and considers 83 different source regions irradiating 47 target tissues, defining the effective dose as presented in ICRP Publications 60 and 103. The computer program was validated against another ICRP dosimetry program, Dose and Risk Calculation (DCAL), that employs the same computational framework in evaluation of occupational and environmental intakes of radionuclides. IDAC-Dose2.1 has a sub-module for absorbed dose calculations in spherical structures of different volumes and composition; this sub-module is intended for absorbed dose estimates in radiopharmaceutical therapy. For nine specific alpha emitters, the absorbed dose contribution from their decay products is also included in the committed absorbed dose calculations. Results: The absorbed doses and effective dose of 131I-iodide determined by IDAC-Dose2.1 were validated against the dosimetry program DCAL, showing identical results. IDAC-Dose2.1 was used to calculate absorbed doses for intravenously administered 18F-FDG and orally administered 99mTc-pertechnetate and 131I-iodide, three frequently used radiopharmaceuticals. Using the tissue weighting factors from ICRP Publication 103, the effective dose per administered activity was estimated to be 0.016 mSv/MBq for 18F-FDG, 0.014 mSv/MBq for 99mTc-pertechnetate, and 16 mSv/MBq for 131I-iodide. Conclusions: The internal dosimetry program IDAC-Dose2.1 was developed and applied to three radiopharmaceuticals for validation against DCAL and to generate improved absorbed dose estimations for diagnostic nuclear medicine using specific absorbed fraction values of the ICRP computational voxel phantoms. The sub-module for absorbed dose calculations in spherical structures 1 mm to 9 cm in diameter and different tissue composition was included to broaden the clinical usefulness of the program. The IDAC-Dose2.1 program is free software for research and available for download at http://www.idac-dose.org.

(Less)
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
DCAL, Diagnostic nuclear medicine, Effective dose, ICRP, IDAC, Internal dosimetry, Radiopharmaceuticals
in
EJNMMI Research
volume
7
article number
88
publisher
BioMed Central (BMC)
external identifiers
  • scopus:85033236572
  • pmid:29098485
  • wos:000414462200001
ISSN
2191-219X
DOI
10.1186/s13550-017-0339-3
language
English
LU publication?
yes
id
a6960af8-83e6-490e-b165-4ec97ec3b7d0
date added to LUP
2017-12-12 15:50:02
date last changed
2024-06-25 10:34:07
@article{a6960af8-83e6-490e-b165-4ec97ec3b7d0,
  abstract     = {{<p>Background: To date, the estimated radiation-absorbed dose to organs and tissues in patients undergoing diagnostic examinations in nuclear medicine is derived via calculations based on models of the human body and the biokinetic behaviour of the radiopharmaceutical. An internal dosimetry computer program, IDAC-Dose2.1, was developed based on the International Commission on Radiological Protection (ICRP)-specific absorbed fractions and computational framework of internal dose assessment given for reference adults in ICRP Publication 133. The program uses the radionuclide decay database of ICRP Publication 107 and considers 83 different source regions irradiating 47 target tissues, defining the effective dose as presented in ICRP Publications 60 and 103. The computer program was validated against another ICRP dosimetry program, Dose and Risk Calculation (DCAL), that employs the same computational framework in evaluation of occupational and environmental intakes of radionuclides. IDAC-Dose2.1 has a sub-module for absorbed dose calculations in spherical structures of different volumes and composition; this sub-module is intended for absorbed dose estimates in radiopharmaceutical therapy. For nine specific alpha emitters, the absorbed dose contribution from their decay products is also included in the committed absorbed dose calculations. Results: The absorbed doses and effective dose of <sup>131</sup>I-iodide determined by IDAC-Dose2.1 were validated against the dosimetry program DCAL, showing identical results. IDAC-Dose2.1 was used to calculate absorbed doses for intravenously administered <sup>18</sup>F-FDG and orally administered <sup>99m</sup>Tc-pertechnetate and <sup>131</sup>I-iodide, three frequently used radiopharmaceuticals. Using the tissue weighting factors from ICRP Publication 103, the effective dose per administered activity was estimated to be 0.016 mSv/MBq for <sup>18</sup>F-FDG, 0.014 mSv/MBq for <sup>99m</sup>Tc-pertechnetate, and 16 mSv/MBq for <sup>131</sup>I-iodide. Conclusions: The internal dosimetry program IDAC-Dose2.1 was developed and applied to three radiopharmaceuticals for validation against DCAL and to generate improved absorbed dose estimations for diagnostic nuclear medicine using specific absorbed fraction values of the ICRP computational voxel phantoms. The sub-module for absorbed dose calculations in spherical structures 1 mm to 9 cm in diameter and different tissue composition was included to broaden the clinical usefulness of the program. The IDAC-Dose2.1 program is free software for research and available for download at http://www.idac-dose.org.</p>}},
  author       = {{Andersson, Martin and Johansson, Lennart and Eckerman, Keith and Mattsson, Sören}},
  issn         = {{2191-219X}},
  keywords     = {{DCAL; Diagnostic nuclear medicine; Effective dose; ICRP; IDAC; Internal dosimetry; Radiopharmaceuticals}},
  language     = {{eng}},
  publisher    = {{BioMed Central (BMC)}},
  series       = {{EJNMMI Research}},
  title        = {{IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms}},
  url          = {{http://dx.doi.org/10.1186/s13550-017-0339-3}},
  doi          = {{10.1186/s13550-017-0339-3}},
  volume       = {{7}},
  year         = {{2017}},
}