Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

A miniature maxthal furnace for X-ray spectroscopy and scattering experiments up to 1200 degrees C

Gorges, Bernard ; Vitoux, Hugo ; Redondo, Pablo ; Carbone, Gerardina LU ; Mocouta, Cristian and Guilera, Gemma (2010) 10th International Conference on Synchrotron Radiation Instrumentation, SRI 2009 In AIP Conference Proceedings 1234. p.572-594
Abstract

We have built a new small furnace to perform high temperature studies up to 1200°C in vacuum or in oxygen atmosphere. This furnace was originally used as a catalytic reactor optimized for the in situ X-ray Absorption Spectroscopy experiments on beamline ID24. It has now been redesigned for use on the ESRF beamline ID01 for in situ Grazing Incidence Small Angle X-ray Scattering experiments. For these experiments high mechanical stability of the sample holder is necessary to keep the alignment of the sample during heating.

Please use this url to cite or link to this publication:
author
; ; ; ; and
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
keywords
Furnace; heater, Synchrotron radiation instrumentation
host publication
SRI 2009 - The 10th International Conference on Synchrotron Radiation Instrumentation
series title
AIP Conference Proceedings
volume
1234
pages
23 pages
conference name
10th International Conference on Synchrotron Radiation Instrumentation, SRI 2009
conference location
Melbourne, VIC, Australia
conference dates
2009-09-27 - 2009-10-02
external identifiers
  • scopus:77955034968
ISSN
0094-243X
1551-7616
ISBN
9780735407824
DOI
10.1063/1.3463269
language
English
LU publication?
no
id
c1d5ca32-8edb-4ddf-af3a-9df7e47279f0
date added to LUP
2021-12-15 12:01:46
date last changed
2024-06-30 00:34:16
@inproceedings{c1d5ca32-8edb-4ddf-af3a-9df7e47279f0,
  abstract     = {{<p>We have built a new small furnace to perform high temperature studies up to 1200°C in vacuum or in oxygen atmosphere. This furnace was originally used as a catalytic reactor optimized for the in situ X-ray Absorption Spectroscopy experiments on beamline ID24. It has now been redesigned for use on the ESRF beamline ID01 for in situ Grazing Incidence Small Angle X-ray Scattering experiments. For these experiments high mechanical stability of the sample holder is necessary to keep the alignment of the sample during heating.</p>}},
  author       = {{Gorges, Bernard and Vitoux, Hugo and Redondo, Pablo and Carbone, Gerardina and Mocouta, Cristian and Guilera, Gemma}},
  booktitle    = {{SRI 2009 - The 10th International Conference on Synchrotron Radiation Instrumentation}},
  isbn         = {{9780735407824}},
  issn         = {{0094-243X}},
  keywords     = {{Furnace; heater; Synchrotron radiation instrumentation}},
  language     = {{eng}},
  pages        = {{572--594}},
  series       = {{AIP Conference Proceedings}},
  title        = {{A miniature maxthal furnace for X-ray spectroscopy and scattering experiments up to 1200 degrees C}},
  url          = {{http://dx.doi.org/10.1063/1.3463269}},
  doi          = {{10.1063/1.3463269}},
  volume       = {{1234}},
  year         = {{2010}},
}