Assessment of air kerma–area product in computed tomography using small solid-state dosemeters
(2026) In Radiation Protection Dosimetry 202(3-4). p.358-370- Abstract
Technological advances in computed tomography (CT) have highlighted limitations of traditional dose descriptors such as computed tomography dose indexvol and dose-length product, particularly for wide-beam and modulated acquisitions. This study investigates a CT-specific, operational air kerma–area product derived from time-resolved measurements using small solid-state dosemeters mounted at the gantry aperture. A mathematical framework is presented that accounts for tube rotation, bow-tie filtration, beam geometry, and the longitudinal dose profile. Model validation was performed using measured air-kerma rate waveforms under free-in-air and phantom conditions, demonstrating that a reproducible kerma–area quantity can be... (More)
Technological advances in computed tomography (CT) have highlighted limitations of traditional dose descriptors such as computed tomography dose indexvol and dose-length product, particularly for wide-beam and modulated acquisitions. This study investigates a CT-specific, operational air kerma–area product derived from time-resolved measurements using small solid-state dosemeters mounted at the gantry aperture. A mathematical framework is presented that accounts for tube rotation, bow-tie filtration, beam geometry, and the longitudinal dose profile. Model validation was performed using measured air-kerma rate waveforms under free-in-air and phantom conditions, demonstrating that a reproducible kerma–area quantity can be derived from fixed-detector measurements. By excluding the kerma–area contribution associated with radiation that does not intersect the object, the proposed approach yields a quantity that is more closely related to patient-incident radiation than conventional output-based KAP concepts in CT. The methodology provides a practical tool for system characterization and quality control in CT dosimetry.
(Less)
- author
- Beganović, Adnan ; Čiva, Lejla M. ; Redžić, Mahira ; Skopljak-Beganović, Amra ; Herrnsdorf, Lars LU and Mattsson, Sören LU
- organization
- publishing date
- 2026-03-01
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Radiation Protection Dosimetry
- volume
- 202
- issue
- 3-4
- pages
- 13 pages
- publisher
- Oxford University Press
- external identifiers
-
- scopus:105032790138
- pmid:41821450
- ISSN
- 0144-8420
- DOI
- 10.1093/rpd/ncag010
- language
- English
- LU publication?
- yes
- additional info
- Publisher Copyright: © The Author(s) 2026. Published by Oxford University Press. All rights reserved.
- id
- c8f92a48-d1e2-4b60-b155-2e663f575ca1
- date added to LUP
- 2026-05-06 15:23:32
- date last changed
- 2026-06-03 17:18:30
@article{c8f92a48-d1e2-4b60-b155-2e663f575ca1,
abstract = {{<p>Technological advances in computed tomography (CT) have highlighted limitations of traditional dose descriptors such as computed tomography dose index<sub>vol</sub> and dose-length product, particularly for wide-beam and modulated acquisitions. This study investigates a CT-specific, operational air kerma–area product derived from time-resolved measurements using small solid-state dosemeters mounted at the gantry aperture. A mathematical framework is presented that accounts for tube rotation, bow-tie filtration, beam geometry, and the longitudinal dose profile. Model validation was performed using measured air-kerma rate waveforms under free-in-air and phantom conditions, demonstrating that a reproducible kerma–area quantity can be derived from fixed-detector measurements. By excluding the kerma–area contribution associated with radiation that does not intersect the object, the proposed approach yields a quantity that is more closely related to patient-incident radiation than conventional output-based KAP concepts in CT. The methodology provides a practical tool for system characterization and quality control in CT dosimetry.</p>}},
author = {{Beganović, Adnan and Čiva, Lejla M. and Redžić, Mahira and Skopljak-Beganović, Amra and Herrnsdorf, Lars and Mattsson, Sören}},
issn = {{0144-8420}},
language = {{eng}},
month = {{03}},
number = {{3-4}},
pages = {{358--370}},
publisher = {{Oxford University Press}},
series = {{Radiation Protection Dosimetry}},
title = {{Assessment of air kerma–area product in computed tomography using small solid-state dosemeters}},
url = {{http://dx.doi.org/10.1093/rpd/ncag010}},
doi = {{10.1093/rpd/ncag010}},
volume = {{202}},
year = {{2026}},
}