ICRP perspective on criteria of acceptability for medical radiological equipment

Mattsson, Sören LU and Vañó, E (2013) In Radiation Protection Dosimetry 153(2). p.158-160
Abstract
The International Commission on Radiological Protection (ICRP) does not have a specific publication or recent detailed advice on acceptability criteria and suspension levels for medical radiological equipment. However, a number of the Commission's publications clearly stress the need to carry out acceptance testing of radiological equipment. Such general recommendations are frequent in earlier and recent reports related to external radiation therapy. Over 30 y ago, the ICRP even included some examples of parameter accuracies concerning acceptance levels in connection with radiotherapy units. Later more general advices related to acceptability tests as important parts of various quality assurance programs were formulated for radiation... (More)
The International Commission on Radiological Protection (ICRP) does not have a specific publication or recent detailed advice on acceptability criteria and suspension levels for medical radiological equipment. However, a number of the Commission's publications clearly stress the need to carry out acceptance testing of radiological equipment. Such general recommendations are frequent in earlier and recent reports related to external radiation therapy. Over 30 y ago, the ICRP even included some examples of parameter accuracies concerning acceptance levels in connection with radiotherapy units. Later more general advices related to acceptability tests as important parts of various quality assurance programs were formulated for radiation therapy as well as for radiodiagnostics without going into details to give values for specific parameters. In the radiodiagnostic field, there are such general recommendations in reports related to equipment for X-ray interventional procedures, digital radiology and computed tomography. The ICRP highly supports the elaboration of detailed and clear acceptability and suspension criteria for equipment used in medical radiology carried out by organisations like International Atomic Energy Agency, International Electrotechnical Commission, European Commission, National Electrical Manufacturers Association (NEMA, USA) and others and consider such criteria as important parts of the quality programmes to guarantee good radiation safety conditions for patients in radiation therapy as well as in radiodiagnostics. (Less)
Please use this url to cite or link to this publication:
author
and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Radiation Protection Dosimetry
volume
153
issue
2
pages
158 - 160
publisher
Oxford University Press
external identifiers
  • wos:000314125700006
  • pmid:23175639
  • scopus:84873839661
  • pmid:23175639
ISSN
1742-3406
DOI
10.1093/rpd/ncs296
language
English
LU publication?
yes
id
cbf2060c-cdc5-47f8-94ed-fff08521800e (old id 3218574)
alternative location
http://www.ncbi.nlm.nih.gov/pubmed/23175639?dopt=Abstract
date added to LUP
2016-04-01 14:45:30
date last changed
2022-05-20 02:06:57
@article{cbf2060c-cdc5-47f8-94ed-fff08521800e,
  abstract     = {{The International Commission on Radiological Protection (ICRP) does not have a specific publication or recent detailed advice on acceptability criteria and suspension levels for medical radiological equipment. However, a number of the Commission's publications clearly stress the need to carry out acceptance testing of radiological equipment. Such general recommendations are frequent in earlier and recent reports related to external radiation therapy. Over 30 y ago, the ICRP even included some examples of parameter accuracies concerning acceptance levels in connection with radiotherapy units. Later more general advices related to acceptability tests as important parts of various quality assurance programs were formulated for radiation therapy as well as for radiodiagnostics without going into details to give values for specific parameters. In the radiodiagnostic field, there are such general recommendations in reports related to equipment for X-ray interventional procedures, digital radiology and computed tomography. The ICRP highly supports the elaboration of detailed and clear acceptability and suspension criteria for equipment used in medical radiology carried out by organisations like International Atomic Energy Agency, International Electrotechnical Commission, European Commission, National Electrical Manufacturers Association (NEMA, USA) and others and consider such criteria as important parts of the quality programmes to guarantee good radiation safety conditions for patients in radiation therapy as well as in radiodiagnostics.}},
  author       = {{Mattsson, Sören and Vañó, E}},
  issn         = {{1742-3406}},
  language     = {{eng}},
  number       = {{2}},
  pages        = {{158--160}},
  publisher    = {{Oxford University Press}},
  series       = {{Radiation Protection Dosimetry}},
  title        = {{ICRP perspective on criteria of acceptability for medical radiological equipment}},
  url          = {{http://dx.doi.org/10.1093/rpd/ncs296}},
  doi          = {{10.1093/rpd/ncs296}},
  volume       = {{153}},
  year         = {{2013}},
}