Double Cerclage Wiring (DCW) of Displaced Stable Olecranon Fractures

Cornefjord Voigt, Gustav LU orcid ; Kostogiannis, Ioannis LU orcid ; Rogmark, Cecilia LU and Wenger, Daniel LU orcid (2026) In Techniques in Hand & Upper Extremity Surgery 30(2).
Abstract

Several methods of surgically treating displaced, ulno-humerally stable olecranon fractures (Mayo type 2a and 2b) have been suggested. Cerclage wires have been used for at least a century to achieve fracture fixation but have been replaced by tension band wiring or plate fixation as the commonly recognized "gold standard" treatments. Thin soft tissues and migrating K-wires result in high complication rates following these 2 methods. We suggest double cerclage wiring as an alternative method that allows for the omission of K-wires. The method can be used for the same indications as tension band wiring: Mayo type 2a and 2b fractures. Two cerclages are placed, in figure-of-eight and figure-of-zero configurations, respectively, through... (More)

Several methods of surgically treating displaced, ulno-humerally stable olecranon fractures (Mayo type 2a and 2b) have been suggested. Cerclage wires have been used for at least a century to achieve fracture fixation but have been replaced by tension band wiring or plate fixation as the commonly recognized "gold standard" treatments. Thin soft tissues and migrating K-wires result in high complication rates following these 2 methods. We suggest double cerclage wiring as an alternative method that allows for the omission of K-wires. The method can be used for the same indications as tension band wiring: Mayo type 2a and 2b fractures. Two cerclages are placed, in figure-of-eight and figure-of-zero configurations, respectively, through separate drill holes distally and through the triceps tendon proximally. In a retrospective study, the reoperation rate and complication rate were twice as high following tension band wiring compared with double cerclage wiring (27% vs. 13% and 45% vs. 18%, respectively). An ongoing RCT will provide more robust evidence, but current studies indicate that double cerclage wiring is a safe and possibly superior alternative to tension band wiring.

(Less)
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
cerclage wiring, double cerclage wiring and cerclage compression wiring., olecranon fractures, tension band wiring
in
Techniques in Hand & Upper Extremity Surgery
volume
30
issue
2
publisher
Lippincott Williams & Wilkins
external identifiers
  • pmid:42090445
  • scopus:105039825172
ISSN
1089-3393
DOI
10.1097/BTH.0000000000000557
language
English
LU publication?
yes
id
cc9bcc48-a4cb-4d7a-bfcb-7dfe25edbf6a
date added to LUP
2026-07-03 14:22:03
date last changed
2026-09-25 21:05:25
@article{cc9bcc48-a4cb-4d7a-bfcb-7dfe25edbf6a,
  abstract     = {{<p>Several methods of surgically treating displaced, ulno-humerally stable olecranon fractures (Mayo type 2a and 2b) have been suggested. Cerclage wires have been used for at least a century to achieve fracture fixation but have been replaced by tension band wiring or plate fixation as the commonly recognized "gold standard" treatments. Thin soft tissues and migrating K-wires result in high complication rates following these 2 methods. We suggest double cerclage wiring as an alternative method that allows for the omission of K-wires. The method can be used for the same indications as tension band wiring: Mayo type 2a and 2b fractures. Two cerclages are placed, in figure-of-eight and figure-of-zero configurations, respectively, through separate drill holes distally and through the triceps tendon proximally. In a retrospective study, the reoperation rate and complication rate were twice as high following tension band wiring compared with double cerclage wiring (27% vs. 13% and 45% vs. 18%, respectively). An ongoing RCT will provide more robust evidence, but current studies indicate that double cerclage wiring is a safe and possibly superior alternative to tension band wiring.</p>}},
  author       = {{Cornefjord Voigt, Gustav and Kostogiannis, Ioannis and Rogmark, Cecilia and Wenger, Daniel}},
  issn         = {{1089-3393}},
  keywords     = {{cerclage wiring; double cerclage wiring and cerclage compression wiring.; olecranon fractures; tension band wiring}},
  language     = {{eng}},
  number       = {{2}},
  publisher    = {{Lippincott Williams & Wilkins}},
  series       = {{Techniques in Hand & Upper Extremity Surgery}},
  title        = {{Double Cerclage Wiring (DCW) of Displaced Stable Olecranon Fractures}},
  url          = {{http://dx.doi.org/10.1097/BTH.0000000000000557}},
  doi          = {{10.1097/BTH.0000000000000557}},
  volume       = {{30}},
  year         = {{2026}},
}