Impact of Wolfmet Tungsten Alloys as Parallel-Hole Collimator Material on Single-Photon Emission Computed Tomography Image Quality and Functional Parameters : A Simulating Medical Imaging Nuclear Detectors Monte Carlo Study

Darami, Maryam ; Mahmoudian, Babak ; Ljungberg, Michael LU orcid and Pirayesh Islamian, Jalil (2023) In World J Nucl Med 22(3). p.217-225
Abstract

Objectives  Collimators have a significant role in image quality and detectability in single-photon emission computed tomography (SPECT) imaging. Using an appropriate alloy that effectively absorbs scattered photons, without induced secondary x-rays, and with proper rigidity and weight may provide an effective approach to the image improvement that conventionally collimators made of lead (Pb). Materials and Methods  A Siemens E.CAM SPECT imaging system equipped with low-energy high-resolution (LEHR) collimator was simulated by the Simulating Medical Imaging Nuclear Detectors Monte Carlo program. Experimental and simulated data were compared based on a 2-mm 99m Tc point source in an acrylic cylindrical Deluxe phantom (Data Spectrum,... (More)

Objectives  Collimators have a significant role in image quality and detectability in single-photon emission computed tomography (SPECT) imaging. Using an appropriate alloy that effectively absorbs scattered photons, without induced secondary x-rays, and with proper rigidity and weight may provide an effective approach to the image improvement that conventionally collimators made of lead (Pb). Materials and Methods  A Siemens E.CAM SPECT imaging system equipped with low-energy high-resolution (LEHR) collimator was simulated by the Simulating Medical Imaging Nuclear Detectors Monte Carlo program. Experimental and simulated data were compared based on a 2-mm 99m Tc point source in an acrylic cylindrical Deluxe phantom (Data Spectrum, Inc). Seven types of tungsten (W) alloys (Wolfmet), with W content from 90 to 97% by weight, were then used as collimator materials of the simulated system. Camera parameters, such as energy- and spatial resolution, image contrast, and collimator-related parameters, such as fraction of septal penetration, scatter-to-primary ratios, and percentage of induced secondary x-rays, due to interactions in the collimator, were evaluated. Results  Acceptable conformity was found for the simulated and experiment systems in terms of energy spectra, 10.113 and 10.140%, full width at half-maximum (FWHM) of the point spread function (PSF) curves, 8.78 and 9.06 mm, sensitivity, 78.46 and 78.34 cps/MBq, and contrast in images of 19.1 mm cold spheres in the Deluxe phantom, 79.17 and 78.97%, respectively. Results on the parameters of the simulated system with LEHR collimator made from the alloys showed that the alloy consisting of 90% W, 6% nickel, and 4% copper provided an FWHM of 8.76 mm, resulting in a 0.2% improvement in spatial resolution. Furthermore, all the Wolfmet collimators showed a 48% reduction in the amount of X-rays production compared to the Pb. Conclusion  A Wolfmet LEHR collimator, made by a combination of W (90%), Ni (6%), and Cu (6%) provides a better image quality and detectability compared to the Pb.

(Less)
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
World J Nucl Med
volume
22
issue
3
pages
217 - 225
publisher
Thieme Medical and Scientific Publishers Pvt. Ltd.
external identifiers
  • pmid:37854088
ISSN
1450-1147
DOI
10.1055/s-0043-1771287
language
English
LU publication?
yes
additional info
The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. ( https://creativecommons.org/licenses/by/4.0/ ).
id
d21088e1-6271-4a9e-b0a0-d3e38c65e72b
date added to LUP
2024-10-25 08:25:26
date last changed
2025-04-04 14:14:50
@article{d21088e1-6271-4a9e-b0a0-d3e38c65e72b,
  abstract     = {{<p>Objectives  Collimators have a significant role in image quality and detectability in single-photon emission computed tomography (SPECT) imaging. Using an appropriate alloy that effectively absorbs scattered photons, without induced secondary x-rays, and with proper rigidity and weight may provide an effective approach to the image improvement that conventionally collimators made of lead (Pb). Materials and Methods  A Siemens E.CAM SPECT imaging system equipped with low-energy high-resolution (LEHR) collimator was simulated by the Simulating Medical Imaging Nuclear Detectors Monte Carlo program. Experimental and simulated data were compared based on a 2-mm 99m Tc point source in an acrylic cylindrical Deluxe phantom (Data Spectrum, Inc). Seven types of tungsten (W) alloys (Wolfmet), with W content from 90 to 97% by weight, were then used as collimator materials of the simulated system. Camera parameters, such as energy- and spatial resolution, image contrast, and collimator-related parameters, such as fraction of septal penetration, scatter-to-primary ratios, and percentage of induced secondary x-rays, due to interactions in the collimator, were evaluated. Results  Acceptable conformity was found for the simulated and experiment systems in terms of energy spectra, 10.113 and 10.140%, full width at half-maximum (FWHM) of the point spread function (PSF) curves, 8.78 and 9.06 mm, sensitivity, 78.46 and 78.34 cps/MBq, and contrast in images of 19.1 mm cold spheres in the Deluxe phantom, 79.17 and 78.97%, respectively. Results on the parameters of the simulated system with LEHR collimator made from the alloys showed that the alloy consisting of 90% W, 6% nickel, and 4% copper provided an FWHM of 8.76 mm, resulting in a 0.2% improvement in spatial resolution. Furthermore, all the Wolfmet collimators showed a 48% reduction in the amount of X-rays production compared to the Pb. Conclusion  A Wolfmet LEHR collimator, made by a combination of W (90%), Ni (6%), and Cu (6%) provides a better image quality and detectability compared to the Pb.</p>}},
  author       = {{Darami, Maryam and Mahmoudian, Babak and Ljungberg, Michael and Pirayesh Islamian, Jalil}},
  issn         = {{1450-1147}},
  language     = {{eng}},
  number       = {{3}},
  pages        = {{217--225}},
  publisher    = {{Thieme Medical and Scientific Publishers Pvt. Ltd.}},
  series       = {{World J Nucl Med}},
  title        = {{Impact of Wolfmet Tungsten Alloys as Parallel-Hole Collimator Material on Single-Photon Emission Computed Tomography Image Quality and Functional Parameters : A Simulating Medical Imaging Nuclear Detectors Monte Carlo Study}},
  url          = {{http://dx.doi.org/10.1055/s-0043-1771287}},
  doi          = {{10.1055/s-0043-1771287}},
  volume       = {{22}},
  year         = {{2023}},
}