Discrimination of ST deviation caused by acute coronary occlusion from normal variants and other abnormal conditions, using computed electrocardiographic imaging based on 12-lead ECG.

Akil, Shahnaz LU ; Al-Mashat, Mariam LU ; Hedén, Bo LU ; Hedeer, Fredrik LU ; Jögi, Jonas LU orcid ; Wang, John J ; Wagner, Galen S ; Warren, James W ; Pahlm, Olle LU and Horáček, B Milan (2013) In Journal of Electrocardiology 46(3). p.197-203
Abstract
Many graphical methods for displaying ST-segment deviation in the ECG have been tried for enhancing decision-making in patients with suspected acute coronary syndromes. Computed electrocardiographic imaging (CEI), based on a mathematical inverse solution, has been recently applied to transform ST-J point measurements made in conventional 12-lead ECG into a display of epicardial potentials in bull's-eye format. The purpose of this study is to assess utility of CEI in the clinical setting.
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Journal of Electrocardiology
volume
46
issue
3
pages
197 - 203
publisher
Elsevier
external identifiers
  • wos:000318457600003
  • pmid:23540511
  • scopus:84876669095
ISSN
1532-8430
DOI
10.1016/j.jelectrocard.2013.02.013
language
English
LU publication?
yes
id
d521f837-52aa-4b60-8f40-3e50694f1232 (old id 3734355)
alternative location
http://www.ncbi.nlm.nih.gov/pubmed/23540511?dopt=Abstract
date added to LUP
2016-04-01 10:48:03
date last changed
2022-04-04 21:29:06
@article{d521f837-52aa-4b60-8f40-3e50694f1232,
  abstract     = {{Many graphical methods for displaying ST-segment deviation in the ECG have been tried for enhancing decision-making in patients with suspected acute coronary syndromes. Computed electrocardiographic imaging (CEI), based on a mathematical inverse solution, has been recently applied to transform ST-J point measurements made in conventional 12-lead ECG into a display of epicardial potentials in bull's-eye format. The purpose of this study is to assess utility of CEI in the clinical setting.}},
  author       = {{Akil, Shahnaz and Al-Mashat, Mariam and Hedén, Bo and Hedeer, Fredrik and Jögi, Jonas and Wang, John J and Wagner, Galen S and Warren, James W and Pahlm, Olle and Horáček, B Milan}},
  issn         = {{1532-8430}},
  language     = {{eng}},
  number       = {{3}},
  pages        = {{197--203}},
  publisher    = {{Elsevier}},
  series       = {{Journal of Electrocardiology}},
  title        = {{Discrimination of ST deviation caused by acute coronary occlusion from normal variants and other abnormal conditions, using computed electrocardiographic imaging based on 12-lead ECG.}},
  url          = {{https://lup.lub.lu.se/search/files/2144103/4139399.pdf}},
  doi          = {{10.1016/j.jelectrocard.2013.02.013}},
  volume       = {{46}},
  year         = {{2013}},
}