Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

IDAC-CAD2VOX : A software for radiation protection calculations for the ICRP reference phantoms which are in an environment described by detailed cad drawings

Andersson, Martin LU ; Herrnsdorf, Lars LU and Mattsson, Sören LU (2017) MEDICAL PHYSICS IN THE BALTIC STATES In 1822-5721 p.10-13
Abstract
A computer program called IDAC-CAD2VOX has been constructed to create geometry input files from CAD drawings for the Monte Carlo simulation program MCNP. The ICRP reference phantoms are incorporated into the CAD drawings to estimate organ doses and the effective dose. The program is applied to a CAD drawing of a house and a 2D drawing of a radiation protection bunker. The created MCNP geometry was visualised by an external program Visual Editor. Dose calculations were performed for a CAD -drawing of a house, where a point source of 1 GBq 99mTc was placed in the attic. The effective dose to the adult male ICRP reference phantom was estimated to be 7.0 µSv when placed in the living room on the second floor. In summary, a method has been... (More)
A computer program called IDAC-CAD2VOX has been constructed to create geometry input files from CAD drawings for the Monte Carlo simulation program MCNP. The ICRP reference phantoms are incorporated into the CAD drawings to estimate organ doses and the effective dose. The program is applied to a CAD drawing of a house and a 2D drawing of a radiation protection bunker. The created MCNP geometry was visualised by an external program Visual Editor. Dose calculations were performed for a CAD -drawing of a house, where a point source of 1 GBq 99mTc was placed in the attic. The effective dose to the adult male ICRP reference phantom was estimated to be 7.0 µSv when placed in the living room on the second floor. In summary, a method has been developed to enable effective dose estimations to adults directly from CAD files and to present the results in a pedagogic and easily understandable way. (Less)
Please use this url to cite or link to this publication:
author
; and
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
keywords
CAD, Monte Carlo simulations, ICRP reference phantoms, Effective dose, IDAC
host publication
Medical Physics in the Baltic States : Proceedings of the 13th International Conference on Medical Physics
series title
1822-5721
editor
Adliene, D.
pages
4 pages
publisher
Kaunas Univ Technology Press
conference name
MEDICAL PHYSICS IN THE BALTIC STATES
conference location
Kaunas, Lithuania
conference dates
2017-11-09 - 2017-11-11
language
English
LU publication?
yes
id
d960a37d-4eca-4b15-9313-42f84f42ebbc
alternative location
http://www.medphys.lt/medphys2017/images/MedPhys2017_Proceedings.pdf
date added to LUP
2019-05-12 15:30:33
date last changed
2021-03-22 15:40:59
@inproceedings{d960a37d-4eca-4b15-9313-42f84f42ebbc,
  abstract     = {{A computer program called IDAC-CAD2VOX has been constructed to create geometry input files from CAD drawings for the Monte Carlo simulation program MCNP. The ICRP reference phantoms are incorporated into the CAD drawings to estimate organ doses and the effective dose.  The program is applied to a CAD drawing of a house and a 2D drawing of a radiation protection bunker. The created MCNP geometry was visualised by an external program  Visual Editor. Dose calculations were performed for a CAD -drawing of a house, where a point source of 1 GBq 99mTc was placed in the attic. The effective dose to the adult male ICRP reference phantom was estimated to be 7.0 µSv when placed in the living room on the second floor. In summary, a method has been developed to enable effective dose estimations to adults directly from CAD files and to present the results in a pedagogic and easily understandable way.}},
  author       = {{Andersson, Martin and Herrnsdorf, Lars and Mattsson, Sören}},
  booktitle    = {{Medical Physics in the Baltic States : Proceedings of the 13th International Conference on Medical Physics}},
  editor       = {{Adliene, D.}},
  keywords     = {{CAD; Monte Carlo simulations; ICRP reference phantoms; Effective dose; IDAC}},
  language     = {{eng}},
  pages        = {{10--13}},
  publisher    = {{Kaunas Univ Technology Press}},
  series       = {{1822-5721}},
  title        = {{IDAC-CAD2VOX : A software for radiation protection calculations for the ICRP reference phantoms which are in an environment described by detailed cad drawings}},
  url          = {{http://www.medphys.lt/medphys2017/images/MedPhys2017_Proceedings.pdf}},