The influence of different technique factors on image quality of chest radiographs as evaluated by modified CEC image quality criteria

Lanhede, B ; Bath, M ; Kheddache, S ; Sund, P ; Bjorneld, L ; Widell, M ; Almen, A LU ; Besjakov, Jack LU ; Mattsson, Sören LU and Tingberg, Anders LU orcid , et al. (2002) In British Journal of Radiology 75(889). p.38-49
Abstract
The Commission of the European Communities (CEC) research project "Predictivity and optimisation in medical radiation protection" addressed fundamental operational limitations in existing radiation protection mechanisms. The first part of the project aimed at investigating (1) whether the CEC image quality criteria could be used for optimization or a radiographic process and (2) whether significant differences in image quality based on these criteria could be detected in a controlled project with well known physical and technical parameters, In the present study. chest radiographs on film were produced using healthy volunteers. Four physical/technical parameters were varied in a carefully controlled manner: tube voltage ( 102 kVp and 14 1... (More)
The Commission of the European Communities (CEC) research project "Predictivity and optimisation in medical radiation protection" addressed fundamental operational limitations in existing radiation protection mechanisms. The first part of the project aimed at investigating (1) whether the CEC image quality criteria could be used for optimization or a radiographic process and (2) whether significant differences in image quality based on these criteria could be detected in a controlled project with well known physical and technical parameters, In the present study. chest radiographs on film were produced using healthy volunteers. Four physical/technical parameters were varied in a carefully controlled manner: tube voltage ( 102 kVp and 14 1 kVp). nominal speed class (160 and 320). maximum film density (1.3 and 1.8) and method of scatter reduction (grid (R = 12) and air gap). The air kerma at the entrance surface was Measured for all patients and the risk-related dose H-Golem, based on calculated organ-equivalent dose conversion coefficients and the measured entrance air kerma values. was calculated, Image quality was evaluated by a group of European expert radiologists using a modified version of the CEC quality criteria. For the two density levels. density level 1.8 was significantly better than 1.3 but at the cost of a higher patient radiation exposure. The correlation between the number of fulfilled quality criteria and H-Golem was generally poor. An air gap technique resulted in lower doses than scatter reduction with a grid but provided comparable image quality. The criteria can be used to highlight optimum radiographic technique in terms of image quality and patient dose, although not unambiguously. A recommendation for good radiographic technique based on a compromise between image quality and risk-related radiation dose to the patient is to use 141 kVp. an air gap, a screen-film system with speed 320 and an optical density of 1.8. (Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; ; ; and , et al. (More)
; ; ; ; ; ; ; ; ; ; ; ; and (Less)
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
British Journal of Radiology
volume
75
issue
889
pages
38 - 49
publisher
British Institute of Radiology
external identifiers
  • pmid:11806957
  • wos:000173746400008
  • scopus:0036177371
ISSN
1748-880X
DOI
10.1259/bjr.75.889.750038
language
English
LU publication?
yes
id
da7033d4-d555-4cc4-99f4-86ce78d44150 (old id 343981)
alternative location
http://bjr.birjournals.org/cgi/reprint/75/889/38
date added to LUP
2016-04-01 15:57:06
date last changed
2024-01-10 22:44:36
@article{da7033d4-d555-4cc4-99f4-86ce78d44150,
  abstract     = {{The Commission of the European Communities (CEC) research project "Predictivity and optimisation in medical radiation protection" addressed fundamental operational limitations in existing radiation protection mechanisms. The first part of the project aimed at investigating (1) whether the CEC image quality criteria could be used for optimization or a radiographic process and (2) whether significant differences in image quality based on these criteria could be detected in a controlled project with well known physical and technical parameters, In the present study. chest radiographs on film were produced using healthy volunteers. Four physical/technical parameters were varied in a carefully controlled manner: tube voltage ( 102 kVp and 14 1 kVp). nominal speed class (160 and 320). maximum film density (1.3 and 1.8) and method of scatter reduction (grid (R = 12) and air gap). The air kerma at the entrance surface was Measured for all patients and the risk-related dose H-Golem, based on calculated organ-equivalent dose conversion coefficients and the measured entrance air kerma values. was calculated, Image quality was evaluated by a group of European expert radiologists using a modified version of the CEC quality criteria. For the two density levels. density level 1.8 was significantly better than 1.3 but at the cost of a higher patient radiation exposure. The correlation between the number of fulfilled quality criteria and H-Golem was generally poor. An air gap technique resulted in lower doses than scatter reduction with a grid but provided comparable image quality. The criteria can be used to highlight optimum radiographic technique in terms of image quality and patient dose, although not unambiguously. A recommendation for good radiographic technique based on a compromise between image quality and risk-related radiation dose to the patient is to use 141 kVp. an air gap, a screen-film system with speed 320 and an optical density of 1.8.}},
  author       = {{Lanhede, B and Bath, M and Kheddache, S and Sund, P and Bjorneld, L and Widell, M and Almen, A and Besjakov, Jack and Mattsson, Sören and Tingberg, Anders and Herrmann, C and Panzer, W and Zankl, M and Mansson, LG}},
  issn         = {{1748-880X}},
  language     = {{eng}},
  number       = {{889}},
  pages        = {{38--49}},
  publisher    = {{British Institute of Radiology}},
  series       = {{British Journal of Radiology}},
  title        = {{The influence of different technique factors on image quality of chest radiographs as evaluated by modified CEC image quality criteria}},
  url          = {{http://dx.doi.org/10.1259/bjr.75.889.750038}},
  doi          = {{10.1259/bjr.75.889.750038}},
  volume       = {{75}},
  year         = {{2002}},
}