Organ doses determined using a RANDO phantom for different radionuclide depositions and photon energies
(2013) Medical physics in the Baltic States 2013 p.103-105- Abstract
- Dose conversion coefficients relating the kerma free-in-air to effective dose have been studied. In order to do so a sampling scheme encompassing all the risk organs and tissues was developed for the Alderson RANDO phantom. Preliminary results are shown for some specific organs irradiated with a point source in the laboratory.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/4092707
- author
- Hörnlund, Mikael and Bernhardsson, Christian LU
- organization
- publishing date
- 2013
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- keywords
- RANDO phantom, dose conversion factors, TLD
- host publication
- Medical Physics in the Baltic States : Proceedings of the 11th International Conference on Medical Physics - Proceedings of the 11th International Conference on Medical Physics
- editor
- Adliene, Diana
- pages
- 4 pages
- publisher
- Kaunas University Of Technology Press
- conference name
- Medical physics in the Baltic States 2013
- conference dates
- 2013-10-11 - 2013-10-12
- external identifiers
-
- wos:000334928000023
- ISSN
- 1822-5721
- language
- English
- LU publication?
- yes
- id
- e8139e76-038a-4d2f-a698-7bd92992638e (old id 4092707)
- alternative location
- http://www.medphys.lt/medphys2013/
- date added to LUP
- 2016-04-01 14:26:13
- date last changed
- 2018-11-21 20:26:46
@inproceedings{e8139e76-038a-4d2f-a698-7bd92992638e, abstract = {{Dose conversion coefficients relating the kerma free-in-air to effective dose have been studied. In order to do so a sampling scheme encompassing all the risk organs and tissues was developed for the Alderson RANDO phantom. Preliminary results are shown for some specific organs irradiated with a point source in the laboratory.}}, author = {{Hörnlund, Mikael and Bernhardsson, Christian}}, booktitle = {{Medical Physics in the Baltic States : Proceedings of the 11th International Conference on Medical Physics}}, editor = {{Adliene, Diana}}, issn = {{1822-5721}}, keywords = {{RANDO phantom; dose conversion factors; TLD}}, language = {{eng}}, pages = {{103--105}}, publisher = {{Kaunas University Of Technology Press}}, title = {{Organ doses determined using a RANDO phantom for different radionuclide depositions and photon energies}}, url = {{https://lup.lub.lu.se/search/files/28717005/H_rnlund_and_Bernhardsson_2013_Organ_doses_determined_using_a_RANDO_phantom_for_different_radionuclide_depositions_and_photon_energies.pdf}}, year = {{2013}}, }