Organ doses determined using a RANDO phantom for different radionuclide depositions and photon energies

Hörnlund, Mikael and Bernhardsson, Christian LU orcid (2013) Medical physics in the Baltic States 2013 p.103-105
Abstract
Dose conversion coefficients relating the kerma free-in-air to effective dose have been studied. In order to do so a sampling scheme encompassing all the risk organs and tissues was developed for the Alderson RANDO phantom. Preliminary results are shown for some specific organs irradiated with a point source in the laboratory.
Please use this url to cite or link to this publication:
author
and
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
keywords
RANDO phantom, dose conversion factors, TLD
host publication
Medical Physics in the Baltic States : Proceedings of the 11th International Conference on Medical Physics - Proceedings of the 11th International Conference on Medical Physics
editor
Adliene, Diana
pages
4 pages
publisher
Kaunas University Of Technology Press
conference name
Medical physics in the Baltic States 2013
conference dates
2013-10-11 - 2013-10-12
external identifiers
  • wos:000334928000023
ISSN
1822-5721
language
English
LU publication?
yes
id
e8139e76-038a-4d2f-a698-7bd92992638e (old id 4092707)
alternative location
http://www.medphys.lt/medphys2013/
date added to LUP
2016-04-01 14:26:13
date last changed
2018-11-21 20:26:46
@inproceedings{e8139e76-038a-4d2f-a698-7bd92992638e,
  abstract     = {{Dose conversion coefficients relating the kerma free-in-air to effective dose have been studied. In order to do so a sampling scheme encompassing all the risk organs and tissues was developed for the Alderson RANDO phantom. Preliminary results are shown for some specific organs irradiated with a point source in the laboratory.}},
  author       = {{Hörnlund, Mikael and Bernhardsson, Christian}},
  booktitle    = {{Medical Physics in the Baltic States : Proceedings of the 11th International Conference on Medical Physics}},
  editor       = {{Adliene, Diana}},
  issn         = {{1822-5721}},
  keywords     = {{RANDO phantom; dose conversion factors; TLD}},
  language     = {{eng}},
  pages        = {{103--105}},
  publisher    = {{Kaunas University Of Technology Press}},
  title        = {{Organ doses determined using a RANDO phantom for different radionuclide depositions and photon energies}},
  url          = {{https://lup.lub.lu.se/search/files/28717005/H_rnlund_and_Bernhardsson_2013_Organ_doses_determined_using_a_RANDO_phantom_for_different_radionuclide_depositions_and_photon_energies.pdf}},