Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Review: Biochemical markers to predict preeclampsia.

Dolberg Anderson, Ulrik LU ; Olsson, M G ; Kristensen, Karl LU ; Åkerström, Bo LU and Hansson, Stefan LU orcid (2012) In Placenta 33. p.42-47
Abstract
Worldwide the prevalence of preeclampsia (PE) ranges from 3 to 8% of pregnancies. 8.5 million cases are reported yearly, but this is probably an underestimate due to the lack of proper diagnosis. PE is the most common cause of fetal and maternal death and yet no specific treatment is available. Reliable biochemical markers for prediction and diagnosis of PE would have a great impact on maternal health and several have been suggested. This review describes PE biochemical markers in general and first trimester PE biochemical markers specifically. The main categories described are angiogenic/anti-angiogenic factors, placental proteins, free fetal hemoglobin (HbF), kidney markers, ultrasound and maternal risk factors. The specific biochemical... (More)
Worldwide the prevalence of preeclampsia (PE) ranges from 3 to 8% of pregnancies. 8.5 million cases are reported yearly, but this is probably an underestimate due to the lack of proper diagnosis. PE is the most common cause of fetal and maternal death and yet no specific treatment is available. Reliable biochemical markers for prediction and diagnosis of PE would have a great impact on maternal health and several have been suggested. This review describes PE biochemical markers in general and first trimester PE biochemical markers specifically. The main categories described are angiogenic/anti-angiogenic factors, placental proteins, free fetal hemoglobin (HbF), kidney markers, ultrasound and maternal risk factors. The specific biochemical markers discussed are: PAPP-A, s-Flt-1/PlGF, s-Endoglin, PP13, cystatin-C, HbF, and α(1)-microglobulin (A1M). PAPP-A and HbF both show potential as predictive biochemical markers in the first trimester with 70% sensitivity at 95% specificity. However, PAPP-A is not PE-specific and needs to be combined with Doppler ultrasound to obtain the same sensitivity as HbF/A1M. Soluble Flt -1 and PlGF are promising biochemical markers that together show high sensitivity from the mid-second trimester. PlGF is somewhat useful from the end of the first trimester. Screening pregnant women with biochemical markers for PE can reduce unnecessary suffering and health care costs by early detection of mothers at increased risk for PE, thus avoiding unnecessary hospitalization of pregnant women with suspect or mild PE and enabling monitoring of the progression of the disease thereby optimizing time for delivery and hopefully reducing the number of premature births. (Less)
Please use this url to cite or link to this publication:
author
; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Placenta
volume
33
pages
42 - 47
publisher
W.B. Saunders
external identifiers
  • wos:000301868000010
  • pmid:22197626
  • scopus:84856001518
  • pmid:22197626
ISSN
1532-3102
DOI
10.1016/j.placenta.2011.11.021
language
English
LU publication?
yes
id
e85f3fb5-231f-4a06-862e-7579c5609982 (old id 2273558)
alternative location
http://www.ncbi.nlm.nih.gov/pubmed/22197626?dopt=Abstract
date added to LUP
2016-04-04 07:08:48
date last changed
2022-03-15 06:36:43
@article{e85f3fb5-231f-4a06-862e-7579c5609982,
  abstract     = {{Worldwide the prevalence of preeclampsia (PE) ranges from 3 to 8% of pregnancies. 8.5 million cases are reported yearly, but this is probably an underestimate due to the lack of proper diagnosis. PE is the most common cause of fetal and maternal death and yet no specific treatment is available. Reliable biochemical markers for prediction and diagnosis of PE would have a great impact on maternal health and several have been suggested. This review describes PE biochemical markers in general and first trimester PE biochemical markers specifically. The main categories described are angiogenic/anti-angiogenic factors, placental proteins, free fetal hemoglobin (HbF), kidney markers, ultrasound and maternal risk factors. The specific biochemical markers discussed are: PAPP-A, s-Flt-1/PlGF, s-Endoglin, PP13, cystatin-C, HbF, and α(1)-microglobulin (A1M). PAPP-A and HbF both show potential as predictive biochemical markers in the first trimester with 70% sensitivity at 95% specificity. However, PAPP-A is not PE-specific and needs to be combined with Doppler ultrasound to obtain the same sensitivity as HbF/A1M. Soluble Flt -1 and PlGF are promising biochemical markers that together show high sensitivity from the mid-second trimester. PlGF is somewhat useful from the end of the first trimester. Screening pregnant women with biochemical markers for PE can reduce unnecessary suffering and health care costs by early detection of mothers at increased risk for PE, thus avoiding unnecessary hospitalization of pregnant women with suspect or mild PE and enabling monitoring of the progression of the disease thereby optimizing time for delivery and hopefully reducing the number of premature births.}},
  author       = {{Dolberg Anderson, Ulrik and Olsson, M G and Kristensen, Karl and Åkerström, Bo and Hansson, Stefan}},
  issn         = {{1532-3102}},
  language     = {{eng}},
  pages        = {{42--47}},
  publisher    = {{W.B. Saunders}},
  series       = {{Placenta}},
  title        = {{Review: Biochemical markers to predict preeclampsia.}},
  url          = {{http://dx.doi.org/10.1016/j.placenta.2011.11.021}},
  doi          = {{10.1016/j.placenta.2011.11.021}},
  volume       = {{33}},
  year         = {{2012}},
}