Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Thrombogenicity of metallic vascular stents in arteries and veins--an experimental study in pigs

Pärsson, Håkan ; Norgren, Lars LU ; Ivancev, Krassi LU ; Thörne, Johan LU and Jönsson, Bo-Anders LU (1990) In European Journal of Vascular Surgery 4(6). p.617-623
Abstract
Endovascular expanding metallic stents were percutaneously implanted in the iliac arteries and veins of pigs. The vessels had been stenosed by a ligature of catgut 4 weeks prior to this. Platelets were labeled with Indium 111 and the deposition onto the dilated and stented areas was dynamically registered for 240 min with a scintillation camera. All six arterial and six venous stents remained patent throughout the examination period. At the site of arterial stenting there was an increase, of deposited activity, and in the veins a decrease. These experimental findings support the use of endovascular stents after dilation, especially in venous stenoses
Please use this url to cite or link to this publication:
author
; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Veins, Platelet deposition, Expandable metallic stents, Arteries
in
European Journal of Vascular Surgery
volume
4
issue
6
pages
617 - 623
publisher
Elsevier
external identifiers
  • scopus:0025687891
ISSN
0950-821X
DOI
10.1016/S0950-821X(05)80818-7
language
English
LU publication?
yes
additional info
The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Emergency medicine/Medicine/Surgery (013240200), Surgery (Lund) (013009000), Medical Radiology Unit (013241410), Radiation Physics, Lund (013034000)
id
ea5aedc7-b214-496f-9cfd-5318439ff807 (old id 1105596)
date added to LUP
2016-04-01 15:45:02
date last changed
2021-09-19 05:55:16
@article{ea5aedc7-b214-496f-9cfd-5318439ff807,
  abstract     = {{Endovascular expanding metallic stents were percutaneously implanted in the iliac arteries and veins of pigs. The vessels had been stenosed by a ligature of catgut 4 weeks prior to this. Platelets were labeled with Indium 111 and the deposition onto the dilated and stented areas was dynamically registered for 240 min with a scintillation camera. All six arterial and six venous stents remained patent throughout the examination period. At the site of arterial stenting there was an increase, of deposited activity, and in the veins a decrease. These experimental findings support the use of endovascular stents after dilation, especially in venous stenoses}},
  author       = {{Pärsson, Håkan and Norgren, Lars and Ivancev, Krassi and Thörne, Johan and Jönsson, Bo-Anders}},
  issn         = {{0950-821X}},
  keywords     = {{Veins; Platelet deposition; Expandable metallic stents; Arteries}},
  language     = {{eng}},
  number       = {{6}},
  pages        = {{617--623}},
  publisher    = {{Elsevier}},
  series       = {{European Journal of Vascular Surgery}},
  title        = {{Thrombogenicity of metallic vascular stents in arteries and veins--an experimental study in pigs}},
  url          = {{http://dx.doi.org/10.1016/S0950-821X(05)80818-7}},
  doi          = {{10.1016/S0950-821X(05)80818-7}},
  volume       = {{4}},
  year         = {{1990}},
}