Performance evaluation with turbulent flow and heat transfer characteristics in rectangular cooling channels with various novel hierarchical rib schemes

Zheng, Shao Fei ; Liu, Guo Qing ; Zhang, Yi ; Wang, He Chen ; Gao, Shu Rong ; Yang, Yan Ru ; Li, Hai Wang ; Sunden, Bengt LU and Wang, Xiao Dong (2023) In International Journal of Heat and Mass Transfer 214.
Abstract

Turbulators, such as ribs, dimples, and pin-fins, play a vital role in the internal cooling efficiency of turbine blades. As a typical turbulator, various rib configurations using a uniform arrangement scheme have indicated high heat transfer enhancement but the friction loss is simultaneously subject to a great increase. In this work, a novel hierarchical arrangement scheme of ribs is developed aiming to improve the cooling efficiency. Adopting the uniform scheme as a baseline, the hierarchical scheme is implemented for six representative rib configurations (including transverse ribs, angled ribs, V-shaped ribs, inverted V-shaped ribs, M-shaped ribs, and inverted M-shaped ribs) and evaluated for its feasibility and generality. For... (More)

Turbulators, such as ribs, dimples, and pin-fins, play a vital role in the internal cooling efficiency of turbine blades. As a typical turbulator, various rib configurations using a uniform arrangement scheme have indicated high heat transfer enhancement but the friction loss is simultaneously subject to a great increase. In this work, a novel hierarchical arrangement scheme of ribs is developed aiming to improve the cooling efficiency. Adopting the uniform scheme as a baseline, the hierarchical scheme is implemented for six representative rib configurations (including transverse ribs, angled ribs, V-shaped ribs, inverted V-shaped ribs, M-shaped ribs, and inverted M-shaped ribs) and evaluated for its feasibility and generality. For different cooling designs, turbulent flow and heat transfer of the ribbed cooling channel are studied by three-dimensional numerical simulations based on the finite volume method with a constructed turbulence model. It is found that for all rib configurations, the hierarchical scheme can remarkably reduce the friction loss as desired, especially for the inverted V-shaped rib with a reduction of up to 50%. Due to the occurrence of flow separation, secondary flows offered by transverse ribs are characterized by a two-dimensional recirculation vortex behind the rib. For other rib configurations, secondary flows present a typical three-dimensional characteristic including the downwash flows along the inclined rib leg and the longitudinal vortices. The usage of the hierarchical scheme with small ribs strongly suppresses these secondary flows, which contributes to the significant decrease in form drag loss. Meanwhile, using the hierarchical scheme produces a slight heat transfer deterioration commonly, which is because the constrained secondary vortices weaken the turbulent mixing and convection heat transfer. Significantly, for the two W-shaped ribs, the limited secondary vortices but fully developed under the hierarchical scheme achieve a higher heat transfer enhancement. Finally, for all considered ribs, the hierarchical scheme can improve the overall performance factor of (Nu/Nu0)/(f/f0)1/3 by more than 10%, and up to 21.15% for the V-shaped rib. Adjusting design variables, including the decreasing ratio of the rib size and the initial rib size, the hierarchical scheme still provides even higher performance enhancement.

(Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Heat transfer, Performance evaluation, Ribs with the hierarchical scheme, Turbine blade internal cooling, Turbulent vortex structures
in
International Journal of Heat and Mass Transfer
volume
214
article number
124459
publisher
Pergamon Press Ltd.
external identifiers
  • scopus:85163846719
ISSN
0017-9310
DOI
10.1016/j.ijheatmasstransfer.2023.124459
language
English
LU publication?
yes
id
f31e90aa-e2f3-4c3f-afba-8ebca853a4e2
date added to LUP
2023-08-28 15:29:52
date last changed
2023-11-08 10:17:10
@article{f31e90aa-e2f3-4c3f-afba-8ebca853a4e2,
  abstract     = {{<p>Turbulators, such as ribs, dimples, and pin-fins, play a vital role in the internal cooling efficiency of turbine blades. As a typical turbulator, various rib configurations using a uniform arrangement scheme have indicated high heat transfer enhancement but the friction loss is simultaneously subject to a great increase. In this work, a novel hierarchical arrangement scheme of ribs is developed aiming to improve the cooling efficiency. Adopting the uniform scheme as a baseline, the hierarchical scheme is implemented for six representative rib configurations (including transverse ribs, angled ribs, V-shaped ribs, inverted V-shaped ribs, M-shaped ribs, and inverted M-shaped ribs) and evaluated for its feasibility and generality. For different cooling designs, turbulent flow and heat transfer of the ribbed cooling channel are studied by three-dimensional numerical simulations based on the finite volume method with a constructed turbulence model. It is found that for all rib configurations, the hierarchical scheme can remarkably reduce the friction loss as desired, especially for the inverted V-shaped rib with a reduction of up to 50%. Due to the occurrence of flow separation, secondary flows offered by transverse ribs are characterized by a two-dimensional recirculation vortex behind the rib. For other rib configurations, secondary flows present a typical three-dimensional characteristic including the downwash flows along the inclined rib leg and the longitudinal vortices. The usage of the hierarchical scheme with small ribs strongly suppresses these secondary flows, which contributes to the significant decrease in form drag loss. Meanwhile, using the hierarchical scheme produces a slight heat transfer deterioration commonly, which is because the constrained secondary vortices weaken the turbulent mixing and convection heat transfer. Significantly, for the two W-shaped ribs, the limited secondary vortices but fully developed under the hierarchical scheme achieve a higher heat transfer enhancement. Finally, for all considered ribs, the hierarchical scheme can improve the overall performance factor of (Nu/Nu<sub>0</sub>)/(f/f<sub>0</sub>)<sup>1/3</sup> by more than 10%, and up to 21.15% for the V-shaped rib. Adjusting design variables, including the decreasing ratio of the rib size and the initial rib size, the hierarchical scheme still provides even higher performance enhancement.</p>}},
  author       = {{Zheng, Shao Fei and Liu, Guo Qing and Zhang, Yi and Wang, He Chen and Gao, Shu Rong and Yang, Yan Ru and Li, Hai Wang and Sunden, Bengt and Wang, Xiao Dong}},
  issn         = {{0017-9310}},
  keywords     = {{Heat transfer; Performance evaluation; Ribs with the hierarchical scheme; Turbine blade internal cooling; Turbulent vortex structures}},
  language     = {{eng}},
  publisher    = {{Pergamon Press Ltd.}},
  series       = {{International Journal of Heat and Mass Transfer}},
  title        = {{Performance evaluation with turbulent flow and heat transfer characteristics in rectangular cooling channels with various novel hierarchical rib schemes}},
  url          = {{http://dx.doi.org/10.1016/j.ijheatmasstransfer.2023.124459}},
  doi          = {{10.1016/j.ijheatmasstransfer.2023.124459}},
  volume       = {{214}},
  year         = {{2023}},
}