Sensor-augmented pump therapy lowers HbA(1c) in suboptimally controlled Type 1 diabetes; a randomized controlled trial.
(2011) In Diabetic Medicine: A journal of the British Diabetic Association 28. p.1158-1167- Abstract
- Aims To investigate the efficacy of sensor-augmented pump therapy vs. multiple daily injection therapy in patients with suboptimally controlled Type 1 diabetes. Methods In this investigator-initiated multi-centre trial (the Eurythmics Trial) in eight outpatient centres in Europe, we randomized 83 patients with Type 1 diabetes (40 women) currently treated with multiple daily injections, age 18-65 years and HbA(1c) ≥ 8.2% (≥ 66 mmol/mol) to 26 weeks of treatment with either a sensor-augmented insulin pump (n = 44) (Paradigm(®) REAL-Time) or continued with multiple daily injections (n = 39). Change in HbA(1c) between baseline and 26 weeks, sensor-derived endpoints and patient-reported outcomes were assessed. Results The trial was completed by... (More)
- Aims To investigate the efficacy of sensor-augmented pump therapy vs. multiple daily injection therapy in patients with suboptimally controlled Type 1 diabetes. Methods In this investigator-initiated multi-centre trial (the Eurythmics Trial) in eight outpatient centres in Europe, we randomized 83 patients with Type 1 diabetes (40 women) currently treated with multiple daily injections, age 18-65 years and HbA(1c) ≥ 8.2% (≥ 66 mmol/mol) to 26 weeks of treatment with either a sensor-augmented insulin pump (n = 44) (Paradigm(®) REAL-Time) or continued with multiple daily injections (n = 39). Change in HbA(1c) between baseline and 26 weeks, sensor-derived endpoints and patient-reported outcomes were assessed. Results The trial was completed by 43/44 (98%) patients in the sensor-augmented insulin pump group and 35/39 (90%) patients in the multiple daily injections group. Mean HbA(1c) at baseline and at 26 weeks changed from 8.46% (sd 0.95) (69 mmol/mol) to 7.23% (sd 0.65) (56 mmol/mol) in the sensor-augmented insulin pump group and from 8.59% (sd 0.82) (70 mmol/mol) to 8.46% (sd 1.04) (69 mmol/mol) in the multiple daily injections group. Mean difference in change in HbA(1c) after 26 weeks was -1.21% (95% confidence interval -1.52 to -0.90, P < 0.001) in favour of the sensor-augmented insulin pump group. This was achieved without an increase in percentage of time spent in hypoglycaemia: between-group difference 0.0% (95% confidence interval -1.6 to 1.7, P = 0.96). There were four episodes of severe hypoglycaemia in the sensor-augmented insulin pump group and one episode in the multiple daily injections group (P = 0.21). Problem Areas in Diabetes and Diabetes Treatment Satisfaction Questionnaire scores improved in the sensor-augmented insulin pump group. Conclusions Sensor augmented pump therapy effectively lowers HbA(1c) in patients with Type 1 diabetes suboptimally controlled with multiple daily injections. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1832258
- author
- organization
- publishing date
- 2011
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Diabetic Medicine: A journal of the British Diabetic Association
- volume
- 28
- pages
- 1158 - 1167
- publisher
- Wiley-Blackwell
- external identifiers
-
- wos:000295003600006
- pmid:21294770
- scopus:79960098673
- pmid:21294770
- ISSN
- 1464-5491
- DOI
- 10.1111/j.1464-5491.2011.03256.x
- language
- English
- LU publication?
- yes
- additional info
- The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Pediatrics/Urology/Gynecology/Endocrinology (013240400)
- id
- fa9f53b2-8ae0-4dd9-8b24-de9693eacc6c (old id 1832258)
- alternative location
- http://www.ncbi.nlm.nih.gov/pubmed/21294770?dopt=Abstract
- date added to LUP
- 2016-04-04 09:41:38
- date last changed
- 2022-05-17 01:41:09
@article{fa9f53b2-8ae0-4dd9-8b24-de9693eacc6c, abstract = {{Aims To investigate the efficacy of sensor-augmented pump therapy vs. multiple daily injection therapy in patients with suboptimally controlled Type 1 diabetes. Methods In this investigator-initiated multi-centre trial (the Eurythmics Trial) in eight outpatient centres in Europe, we randomized 83 patients with Type 1 diabetes (40 women) currently treated with multiple daily injections, age 18-65 years and HbA(1c) ≥ 8.2% (≥ 66 mmol/mol) to 26 weeks of treatment with either a sensor-augmented insulin pump (n = 44) (Paradigm(®) REAL-Time) or continued with multiple daily injections (n = 39). Change in HbA(1c) between baseline and 26 weeks, sensor-derived endpoints and patient-reported outcomes were assessed. Results The trial was completed by 43/44 (98%) patients in the sensor-augmented insulin pump group and 35/39 (90%) patients in the multiple daily injections group. Mean HbA(1c) at baseline and at 26 weeks changed from 8.46% (sd 0.95) (69 mmol/mol) to 7.23% (sd 0.65) (56 mmol/mol) in the sensor-augmented insulin pump group and from 8.59% (sd 0.82) (70 mmol/mol) to 8.46% (sd 1.04) (69 mmol/mol) in the multiple daily injections group. Mean difference in change in HbA(1c) after 26 weeks was -1.21% (95% confidence interval -1.52 to -0.90, P < 0.001) in favour of the sensor-augmented insulin pump group. This was achieved without an increase in percentage of time spent in hypoglycaemia: between-group difference 0.0% (95% confidence interval -1.6 to 1.7, P = 0.96). There were four episodes of severe hypoglycaemia in the sensor-augmented insulin pump group and one episode in the multiple daily injections group (P = 0.21). Problem Areas in Diabetes and Diabetes Treatment Satisfaction Questionnaire scores improved in the sensor-augmented insulin pump group. Conclusions Sensor augmented pump therapy effectively lowers HbA(1c) in patients with Type 1 diabetes suboptimally controlled with multiple daily injections.}}, author = {{Hermanides, J and Nørgaard, K and Bruttomesso, D and Mathieu, C and Frid, Anders and Dayan, C M and Diem, P and Fermon, C and Wentholt, I M E and Hoekstra, J B L and Devries, J H}}, issn = {{1464-5491}}, language = {{eng}}, pages = {{1158--1167}}, publisher = {{Wiley-Blackwell}}, series = {{Diabetic Medicine: A journal of the British Diabetic Association}}, title = {{Sensor-augmented pump therapy lowers HbA(1c) in suboptimally controlled Type 1 diabetes; a randomized controlled trial.}}, url = {{http://dx.doi.org/10.1111/j.1464-5491.2011.03256.x}}, doi = {{10.1111/j.1464-5491.2011.03256.x}}, volume = {{28}}, year = {{2011}}, }