Redundancy Analysis of a Dual Wound PMSM Traction Machine
(2026) In CODEN:LUTEDX/TEIE EIEM01 20261Division for Industrial Electrical Engineering and Automation
- Abstract
- With the More Electric Aircraft concept, the aviation industry is moving toward electrification of onboard sub-systems. This transition from mechanical to electrical power places high demands on onboard electrical power generation, requiring systems that can guarantee continuous and safe operation even in the event of a component failure mid-flight.
To generate power on a gas turbine driven aircraft, an electrical machine is coupled to the axle with the possibility to use it both as a generator and a motor. With auxiliary systems depending on the power generated by the electrical machine it is important that it can continue operation even at the event of component failure. A primary strategy for ensuring high reliability is the use of... (More) - With the More Electric Aircraft concept, the aviation industry is moving toward electrification of onboard sub-systems. This transition from mechanical to electrical power places high demands on onboard electrical power generation, requiring systems that can guarantee continuous and safe operation even in the event of a component failure mid-flight.
To generate power on a gas turbine driven aircraft, an electrical machine is coupled to the axle with the possibility to use it both as a generator and a motor. With auxiliary systems depending on the power generated by the electrical machine it is important that it can continue operation even at the event of component failure. A primary strategy for ensuring high reliability is the use of multi-phase machines which have several advantages over three-phase machines such as improved fault tolerance and improved thermal distribution. By developing a simulation model of a six-phase interior permanent magnet synchronous machine, configured as two electrically isolated three-phase winding sets, the machines inherent redundancy is evaluated under severe fault conditions, including open- phase fault, symmetric three-phase short circuit and loss of modulation.
The simulation model is developed in Simulink and includes a model of the six-phase machine, power electronics, faults and control using field-oriented control. The model is validated against both another more established model as well as against the physical machine that the model is based upon. Results show that the simulation models fault response behaviour aligns qualitatively well with the model its validated against as well as the machine it is based upon for the tested operating points, but with deviations in torque in both healthy and faulty operation. The results show that an open-phase fault creates a torque ripple at twice the electrical frequency, together with an uncontrolled rise of the phase currents in the faulted set. A symmetric three-phase short circuit produces a braking torque and post- fault currents whose severity depends strongly on the operating point. A loss of modulation lowers the torque below base speed, where no current flows in the faulted set and turning that set into an uncontrolled generator in the field weakening region above base speed, affecting the machines torque production and the systems power electronics. (Less) - Popular Abstract
- What happens if the electrical machine that is powering the plane’s vital electrical systems fail? To find out, we caused a series of faults in a machine that is built as two machines in one. It turns out the machine can keep running on its healthy half, but only if the user is aware of how the different faults impact the system and makes sure that it can handle them.
An aircraft flying at ten thousand metres altitude cannot pull over and wait for help. Everything on board must either keep working or fail in a way the aircraft can handle. This challenge grows as the industry replaces mechanical, hydraulic and compressed air systems with electrical ones in pursuit of a concept known as the More Electric Aircraft. Here, one electrical... (More) - What happens if the electrical machine that is powering the plane’s vital electrical systems fail? To find out, we caused a series of faults in a machine that is built as two machines in one. It turns out the machine can keep running on its healthy half, but only if the user is aware of how the different faults impact the system and makes sure that it can handle them.
An aircraft flying at ten thousand metres altitude cannot pull over and wait for help. Everything on board must either keep working or fail in a way the aircraft can handle. This challenge grows as the industry replaces mechanical, hydraulic and compressed air systems with electrical ones in pursuit of a concept known as the More Electric Aircraft. Here, one electrical machine on the jet engine produces power for vital systems, making the reliability of this machine critically important.
One promising way to increase the fault tolerance of the system is to build a backup into the machine itself. Electrical machines normally get their current through three sets of windings, known as phases. The machine we studied has six of them, resulting in two complete machines in the same housing, sharing one shaft. If a fault knocks out one half, the other half should be able to keep going.
The problem is that the two halves are not fully independent. They share the same iron core, which links them through their magnetic fields, so a fault in one half spills over into the healthy one. Understanding how the halves affect each other was the core of this thesis.
We built a computer models of the machine in Simulink and Simscape, its power electronics and control system, and checked it against a real machine in the lab. We then created three faults, a broken phase wire, a short circuit across one winding set, and a sudden loss of the control electronics for one half.
With a broken wire the machine keeps going, but it shudders. The torque, the machine’s turning force, pulses, and the currents in the remaining wires rise sharply, which risks overheating. A short circuit turns the faulty half into a brake, and the speed decides the danger. At low speed the braking is strong and steals most of the torque. At high speed the braking fades, but a very large current and torque ripple
appear instead, which the machine must withstand. The dead electronics were an interesting case. A spinning permanent magnet machine always produces voltage, because you cannot switch off a the magnets in the rotor. If the machine spins fast enough, the failed half acts as an uncontrolled generator that loses current control and pumps power back into the electrical system, raising the voltage and threatening other electronics.
The doubled winding design does give the machine a backup, what engineers call redundancy. The machine kept supplying power where an ordinary machine would have stopped. But the backup does not come for free. It needs fast fault detection and a control system that knows what to do when something breaks in order to be safe enough in many cases. The model and measurements from this thesis are a starting point for designing exactly that, for the More Electric Aircraft. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/student-papers/record/9248984
- author
- Rüetschi, Michael LU and Gerdstigen, Axel LU
- supervisor
-
- Mats Alaküla LU
- Sebastian Fant LU
- organization
- course
- EIEM01 20261
- year
- 2026
- type
- H3 - Professional qualifications (4 Years - )
- subject
- publication/series
- CODEN:LUTEDX/TEIE
- report number
- 5571
- language
- English
- id
- 9248984
- date added to LUP
- 2026-09-23 16:36:36
- date last changed
- 2026-09-23 16:36:36
@misc{9248984,
abstract = {{With the More Electric Aircraft concept, the aviation industry is moving toward electrification of onboard sub-systems. This transition from mechanical to electrical power places high demands on onboard electrical power generation, requiring systems that can guarantee continuous and safe operation even in the event of a component failure mid-flight.
To generate power on a gas turbine driven aircraft, an electrical machine is coupled to the axle with the possibility to use it both as a generator and a motor. With auxiliary systems depending on the power generated by the electrical machine it is important that it can continue operation even at the event of component failure. A primary strategy for ensuring high reliability is the use of multi-phase machines which have several advantages over three-phase machines such as improved fault tolerance and improved thermal distribution. By developing a simulation model of a six-phase interior permanent magnet synchronous machine, configured as two electrically isolated three-phase winding sets, the machines inherent redundancy is evaluated under severe fault conditions, including open- phase fault, symmetric three-phase short circuit and loss of modulation.
The simulation model is developed in Simulink and includes a model of the six-phase machine, power electronics, faults and control using field-oriented control. The model is validated against both another more established model as well as against the physical machine that the model is based upon. Results show that the simulation models fault response behaviour aligns qualitatively well with the model its validated against as well as the machine it is based upon for the tested operating points, but with deviations in torque in both healthy and faulty operation. The results show that an open-phase fault creates a torque ripple at twice the electrical frequency, together with an uncontrolled rise of the phase currents in the faulted set. A symmetric three-phase short circuit produces a braking torque and post- fault currents whose severity depends strongly on the operating point. A loss of modulation lowers the torque below base speed, where no current flows in the faulted set and turning that set into an uncontrolled generator in the field weakening region above base speed, affecting the machines torque production and the systems power electronics.}},
author = {{Rüetschi, Michael and Gerdstigen, Axel}},
language = {{eng}},
note = {{Student Paper}},
series = {{CODEN:LUTEDX/TEIE}},
title = {{Redundancy Analysis of a Dual Wound PMSM Traction Machine}},
year = {{2026}},
}