Robot Self-Calibration of Nonlinear Joint Dynamics

Tired, Axel (2026)
Department of Automatic Control
Abstract
Demands for accurate industrial robots has driven an increasing need for accessible and reliable calibration methods. Robot manipulators operating in environments where large external forces are present, or carrying heavy tools, suffer from inaccuracies caused by joint elasticities, both from external loads and from gravity acting on the robot links themselves and on the payload. Calibration methods for identifying joint stiffnesses are therefore of great importance to compensate for these effects and ultimately obtain more accurate robot models.
The clamping method, where a robot arm is attached to a rigid point in the environment and torques are exerted on the joints using the robot’s own motors, provides a straightforward approach to... (More)
Demands for accurate industrial robots has driven an increasing need for accessible and reliable calibration methods. Robot manipulators operating in environments where large external forces are present, or carrying heavy tools, suffer from inaccuracies caused by joint elasticities, both from external loads and from gravity acting on the robot links themselves and on the payload. Calibration methods for identifying joint stiffnesses are therefore of great importance to compensate for these effects and ultimately obtain more accurate robot models.
The clamping method, where a robot arm is attached to a rigid point in the environment and torques are exerted on the joints using the robot’s own motors, provides a straightforward approach to joint stiffness identification. However, the assumption of a completely rigid attachment point is not always valid, which may corrupt the identified joint stiffnesses. To address this limitation, a flexible clamping device extends the idea of clamping by combining a more elastic attachment point with a measuring device, thereby accomplishing a virtually rigid clamping point.
This thesis investigates a method for identifying joint stiffnesses using the flexible clamping device, evaluated through MapleSim simulations. The feasibility of the method is further assessed by applying the identification method to experimental data collected from a physical experiment.
Under idealized simulation conditions, the method correctly recovers the relationship between torque and joint deflections, but shows inconsistent accuracy when using a different configuration of the flexclamp, where a lower stiffness results in increased motion at the end-effector. When other joint uncertainties such as passive joint elasticities are included, the identification deteriorates. In a physical experiment, additional complexity arises from practical challenges, such as the robot arm coming to a sudden stop when reaching torque limitations.
The results suggest that while the method shows promise as an extension of the clamping method, further work is needed to investigate the flexclamp’s full ability to identify additional joint properties. In particular, utilizing force measurements from the flexclamp for identification of passive joint elasticities, and more thoroughly investigating how different clamping configurations can aid the identification procedure, are identified as promising directions for future work. (Less)
Please use this url to cite or link to this publication:
author
Tired, Axel
supervisor
organization
year
type
H3 - Professional qualifications (4 Years - )
subject
report number
TFRT-6329
other publication id
0280-5316
language
English
id
9251428
date added to LUP
2026-09-18 11:49:34
date last changed
2026-09-18 11:49:34
@misc{9251428,
  abstract     = {{Demands for accurate industrial robots has driven an increasing need for accessible and reliable calibration methods. Robot manipulators operating in environments where large external forces are present, or carrying heavy tools, suffer from inaccuracies caused by joint elasticities, both from external loads and from gravity acting on the robot links themselves and on the payload. Calibration methods for identifying joint stiffnesses are therefore of great importance to compensate for these effects and ultimately obtain more accurate robot models.
 The clamping method, where a robot arm is attached to a rigid point in the environment and torques are exerted on the joints using the robot’s own motors, provides a straightforward approach to joint stiffness identification. However, the assumption of a completely rigid attachment point is not always valid, which may corrupt the identified joint stiffnesses. To address this limitation, a flexible clamping device extends the idea of clamping by combining a more elastic attachment point with a measuring device, thereby accomplishing a virtually rigid clamping point.
 This thesis investigates a method for identifying joint stiffnesses using the flexible clamping device, evaluated through MapleSim simulations. The feasibility of the method is further assessed by applying the identification method to experimental data collected from a physical experiment.
 Under idealized simulation conditions, the method correctly recovers the relationship between torque and joint deflections, but shows inconsistent accuracy when using a different configuration of the flexclamp, where a lower stiffness results in increased motion at the end-effector. When other joint uncertainties such as passive joint elasticities are included, the identification deteriorates. In a physical experiment, additional complexity arises from practical challenges, such as the robot arm coming to a sudden stop when reaching torque limitations.
 The results suggest that while the method shows promise as an extension of the clamping method, further work is needed to investigate the flexclamp’s full ability to identify additional joint properties. In particular, utilizing force measurements from the flexclamp for identification of passive joint elasticities, and more thoroughly investigating how different clamping configurations can aid the identification procedure, are identified as promising directions for future work.}},
  author       = {{Tired, Axel}},
  language     = {{eng}},
  note         = {{Student Paper}},
  title        = {{Robot Self-Calibration of Nonlinear Joint Dynamics}},
  year         = {{2026}},
}