Calibration and Implementation of Robot for Detection of X-rays

Bring, Björn (2018)
Department of Automatic Control
Abstract
While industrial robots have traditionally been designed for tasks such as pick-and-place that require a high repeatability, an increasing demand for off-line control and high-precision applications have in recent decades put higher demands on the accuracy of robots. One application in that vain is the detection of X-rays that have been scattered from a sample during X-ray diffraction, which produces interference peaks of very well-defined angles. To that end, a robot has been installed at the MAX IV synchrotron facility with the intention of having it maneuvering an X-ray detector, and the aim of this thesis is thus to improve the pose accuracy of the robot to a level that is feasible for conducting such experiments.

The robot’s... (More)
While industrial robots have traditionally been designed for tasks such as pick-and-place that require a high repeatability, an increasing demand for off-line control and high-precision applications have in recent decades put higher demands on the accuracy of robots. One application in that vain is the detection of X-rays that have been scattered from a sample during X-ray diffraction, which produces interference peaks of very well-defined angles. To that end, a robot has been installed at the MAX IV synchrotron facility with the intention of having it maneuvering an X-ray detector, and the aim of this thesis is thus to improve the pose accuracy of the robot to a level that is feasible for conducting such experiments.

The robot’s kinematics is calibrated through means of an optical CMM, and the joint characteristics such as backlash, friction, and joint stiffness are identified by performing a clamping routine, where the robot’s end-effector is rigidly fixed to the environment. Furthermore, the calibrated model is implemented off-line in order to facilitate the control of the robot by means of the spherical coordinates that are commonly used in X-ray diffraction. The results show that the calibrated model achieved an accuracy of 180 mm, which is close to the anticipated value of 150 mm. This means that the robot is ready to be taken into operation, even though further attempts at improving the accuracy may be undertaken in the future. (Less)
Please use this url to cite or link to this publication:
author
Bring, Björn
supervisor
organization
year
type
H3 - Professional qualifications (4 Years - )
subject
report number
TFRT-6050
ISSN
0280-5316
language
English
id
8953421
date added to LUP
2018-06-29 12:22:29
date last changed
2018-06-29 12:22:29
@misc{8953421,
  abstract     = {{While industrial robots have traditionally been designed for tasks such as pick-and-place that require a high repeatability, an increasing demand for off-line control and high-precision applications have in recent decades put higher demands on the accuracy of robots. One application in that vain is the detection of X-rays that have been scattered from a sample during X-ray diffraction, which produces interference peaks of very well-defined angles. To that end, a robot has been installed at the MAX IV synchrotron facility with the intention of having it maneuvering an X-ray detector, and the aim of this thesis is thus to improve the pose accuracy of the robot to a level that is feasible for conducting such experiments.

 The robot’s kinematics is calibrated through means of an optical CMM, and the joint characteristics such as backlash, friction, and joint stiffness are identified by performing a clamping routine, where the robot’s end-effector is rigidly fixed to the environment. Furthermore, the calibrated model is implemented off-line in order to facilitate the control of the robot by means of the spherical coordinates that are commonly used in X-ray diffraction. The results show that the calibrated model achieved an accuracy of 180 mm, which is close to the anticipated value of 150 mm. This means that the robot is ready to be taken into operation, even though further attempts at improving the accuracy may be undertaken in the future.}},
  author       = {{Bring, Björn}},
  issn         = {{0280-5316}},
  language     = {{eng}},
  note         = {{Student Paper}},
  title        = {{Calibration and Implementation of Robot for Detection of X-rays}},
  year         = {{2018}},
}