Computerised assistance for warfarin dosage - Effects on treatment quality
(2012) In European Journal of Internal Medicine 23(8). p.742-744- Abstract
- Background: Well-managed warfarin treatment with a high time in therapeutic range (TTR) corresponds to fewer bleedings or thromboembolic complications. Many small centres manage their warfarin dosing manually, with little or no knowledge of their treatment quality as measured by TTR. AuriculA is a Swedish National web-based anticoagulation dosing system. Our hypothesis was that the web based dosing system, compared to manual dosing, would improve the TTR. Methods: Retrospective cohort study of medical records from patients with atrial fibrillation on warfarin treatment from two centres, with previously manual warfarin dosing regimens. Data for calculation of TTR was extracted manually from medical records from the time when using manual... (More)
- Background: Well-managed warfarin treatment with a high time in therapeutic range (TTR) corresponds to fewer bleedings or thromboembolic complications. Many small centres manage their warfarin dosing manually, with little or no knowledge of their treatment quality as measured by TTR. AuriculA is a Swedish National web-based anticoagulation dosing system. Our hypothesis was that the web based dosing system, compared to manual dosing, would improve the TTR. Methods: Retrospective cohort study of medical records from patients with atrial fibrillation on warfarin treatment from two centres, with previously manual warfarin dosing regimens. Data for calculation of TTR was extracted manually from medical records from the time when using manual dosing and compared with the computerised regimen. Results: In centre 1, the mean TTR was significantly increased after the introduction of AuriculA, from 64.3% (95% CI 58.8-69.8) to 71.3% (95% CI 67.7-74.8), p=0.03. In centre 2, a high TTR of 73.6% (95% CI 71.3-75.9) was maintained after the implementation, 74.0% (95% CI 71.6-76.3). INR tests were prescribed significantly more frequent after the introduction of AuriculA in both centres; 20% more often at centre 1 and 21% at centre 2. Conclusion: Computerised dosing assistance within the Swedish national quality registry AuriculA improves or maintains a high treatment quality with warfarin as measured by TTR. (C) 2012 European Federation of Internal Medicine. Published by Elsevier B. V. All rights reserved. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/3256241
- author
- Dimberg, Ivar ; Grzymala-Lubanski, Bartosz ; Hagerfelth, Anette ; Rosenqvist, Marten ; Svensson, Peter LU and Sjalander, Anders
- organization
- publishing date
- 2012
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- Anticoagulation, Warfarin, Atrial fibrillation
- in
- European Journal of Internal Medicine
- volume
- 23
- issue
- 8
- pages
- 742 - 744
- publisher
- Elsevier
- external identifiers
-
- wos:000310577800023
- scopus:84869085735
- pmid:22917757
- ISSN
- 1879-0828
- DOI
- 10.1016/j.ejim.2012.07.011
- language
- English
- LU publication?
- yes
- id
- 1f28a09f-e238-41a8-90a1-8c4eb1703550 (old id 3256241)
- date added to LUP
- 2016-04-01 09:53:20
- date last changed
- 2022-04-19 20:36:04
@article{1f28a09f-e238-41a8-90a1-8c4eb1703550, abstract = {{Background: Well-managed warfarin treatment with a high time in therapeutic range (TTR) corresponds to fewer bleedings or thromboembolic complications. Many small centres manage their warfarin dosing manually, with little or no knowledge of their treatment quality as measured by TTR. AuriculA is a Swedish National web-based anticoagulation dosing system. Our hypothesis was that the web based dosing system, compared to manual dosing, would improve the TTR. Methods: Retrospective cohort study of medical records from patients with atrial fibrillation on warfarin treatment from two centres, with previously manual warfarin dosing regimens. Data for calculation of TTR was extracted manually from medical records from the time when using manual dosing and compared with the computerised regimen. Results: In centre 1, the mean TTR was significantly increased after the introduction of AuriculA, from 64.3% (95% CI 58.8-69.8) to 71.3% (95% CI 67.7-74.8), p=0.03. In centre 2, a high TTR of 73.6% (95% CI 71.3-75.9) was maintained after the implementation, 74.0% (95% CI 71.6-76.3). INR tests were prescribed significantly more frequent after the introduction of AuriculA in both centres; 20% more often at centre 1 and 21% at centre 2. Conclusion: Computerised dosing assistance within the Swedish national quality registry AuriculA improves or maintains a high treatment quality with warfarin as measured by TTR. (C) 2012 European Federation of Internal Medicine. Published by Elsevier B. V. All rights reserved.}}, author = {{Dimberg, Ivar and Grzymala-Lubanski, Bartosz and Hagerfelth, Anette and Rosenqvist, Marten and Svensson, Peter and Sjalander, Anders}}, issn = {{1879-0828}}, keywords = {{Anticoagulation; Warfarin; Atrial fibrillation}}, language = {{eng}}, number = {{8}}, pages = {{742--744}}, publisher = {{Elsevier}}, series = {{European Journal of Internal Medicine}}, title = {{Computerised assistance for warfarin dosage - Effects on treatment quality}}, url = {{http://dx.doi.org/10.1016/j.ejim.2012.07.011}}, doi = {{10.1016/j.ejim.2012.07.011}}, volume = {{23}}, year = {{2012}}, }