New Clinical Measures of Hand and Wrist Proprioception : A Pilot Study for Evaluating Discriminative Validity and Test-retest Reliability in Individuals with Wrist Disability
(2025) In Journal of rehabilitation medicine. Clinical communications 8. p.1-8- Abstract
OBJECTIVE: To evaluate psychometric properties of newly developed hand and wrist proprioception tests.
DESIGN: Cross-sectional and test-retest comparisons.
SUBJECTS/PATIENTS: Twenty-six individuals (mean age 40 years) with wrist disability (> 3 months) due to traumatic injury or general instability.
METHODS: Pointing acuity (with eyes open and closed), active joint position sense (in extension, flexion, radial- and ulnar deviation) and grip force reproduction were measured by 1 rater on 2 occasions, 1 week apart. The mean absolute error was calculated for each test. Discriminative validity (affected vs non-affected hand/wrist) was evaluated by paired
t-test and test-retest reliability with Intraclass... (More)OBJECTIVE: To evaluate psychometric properties of newly developed hand and wrist proprioception tests.
DESIGN: Cross-sectional and test-retest comparisons.
SUBJECTS/PATIENTS: Twenty-six individuals (mean age 40 years) with wrist disability (> 3 months) due to traumatic injury or general instability.
METHODS: Pointing acuity (with eyes open and closed), active joint position sense (in extension, flexion, radial- and ulnar deviation) and grip force reproduction were measured by 1 rater on 2 occasions, 1 week apart. The mean absolute error was calculated for each test. Discriminative validity (affected vs non-affected hand/wrist) was evaluated by paired
t-test and test-retest reliability with Intraclass Correlation Coefficient (ICC).
RESULTS: The pointing acuity test with eyes closed gave higher errors for the affected hand/wrist (
p = 0.08) and good ICCs (0.80-0.85), while the test with eyes open had poor discriminative ability (
p = 0.32) and test-retest reliability (ICC 0.13-0.16). The active joint position sense test showed higher error in flexion for the affected wrist (
p = 0.03), and the ICC was moderate (0.51). The remaining joint directions and the grip force reproduction test had poor discriminative ability (
p = 0.21-0.94) and poor to moderate ICCs (0.00-0.65).
CONCLUSION: The pointing acuity test with eyes closed and the active joint position test in flexion show-ed promising results but need further evaluation in larger samples.
(Less)
- author
- Sontag, Maria
LU
; Röijezon, Ulrik
LU
; Brogårdh, Christina
LU
and Ekstrand, Elisabeth
LU
- organization
- publishing date
- 2025
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Journal of rehabilitation medicine. Clinical communications
- volume
- 8
- article number
- 43929
- pages
- 1 - 8
- publisher
- Medical Journals Sweden AB
- external identifiers
-
- pmid:41195404
- ISSN
- 2003-0711
- DOI
- 10.2340/jrm-cc.v8.43929
- language
- English
- LU publication?
- yes
- additional info
- © 2025 The Author(s).
- id
- 026bb49c-2957-4513-a4bf-0800eccd705a
- date added to LUP
- 2026-02-24 11:44:38
- date last changed
- 2026-02-26 02:56:09
@article{026bb49c-2957-4513-a4bf-0800eccd705a,
abstract = {{<p>OBJECTIVE: To evaluate psychometric properties of newly developed hand and wrist proprioception tests.</p><p>DESIGN: Cross-sectional and test-retest comparisons.</p><p>SUBJECTS/PATIENTS: Twenty-six individuals (mean age 40 years) with wrist disability (> 3 months) due to traumatic injury or general instability.</p><p>METHODS: Pointing acuity (with eyes open and closed), active joint position sense (in extension, flexion, radial- and ulnar deviation) and grip force reproduction were measured by 1 rater on 2 occasions, 1 week apart. The mean absolute error was calculated for each test. Discriminative validity (affected vs non-affected hand/wrist) was evaluated by paired <br>
t-test and test-retest reliability with Intraclass Correlation Coefficient (ICC).<br>
</p><p>RESULTS: The pointing acuity test with eyes closed gave higher errors for the affected hand/wrist (<br>
p = 0.08) and good ICCs (0.80-0.85), while the test with eyes open had poor discriminative ability (<br>
p = 0.32) and test-retest reliability (ICC 0.13-0.16). The active joint position sense test showed higher error in flexion for the affected wrist (<br>
p = 0.03), and the ICC was moderate (0.51). The remaining joint directions and the grip force reproduction test had poor discriminative ability (<br>
p = 0.21-0.94) and poor to moderate ICCs (0.00-0.65).<br>
</p><p>CONCLUSION: The pointing acuity test with eyes closed and the active joint position test in flexion show-ed promising results but need further evaluation in larger samples.</p>}},
author = {{Sontag, Maria and Röijezon, Ulrik and Brogårdh, Christina and Ekstrand, Elisabeth}},
issn = {{2003-0711}},
language = {{eng}},
pages = {{1--8}},
publisher = {{Medical Journals Sweden AB}},
series = {{Journal of rehabilitation medicine. Clinical communications}},
title = {{New Clinical Measures of Hand and Wrist Proprioception : A Pilot Study for Evaluating Discriminative Validity and Test-retest Reliability in Individuals with Wrist Disability}},
url = {{http://dx.doi.org/10.2340/jrm-cc.v8.43929}},
doi = {{10.2340/jrm-cc.v8.43929}},
volume = {{8}},
year = {{2025}},
}